You are here:
Products » Automation » Identification Systems » CIS3
|
Identification System CIS3The Identification System CIS3 is the predominantly used standard system in the CIS system family. The CIS3 features compact data carriers. Typical applications are, e. g., the coding of recirculating product carriers or larger tools. The data carriers are screwed on the product to be identified or the round design is bonded in a countersunk hole. The antenna and the interface electronics are fully integrated in the read heads and the read/write head. The data carrier and the head contain stick-shaped antennae. This configuration requires mounting with the same orientation of the head and data carrier. This orientation can be seen from a printed arrow marking. This fact means that the data carrier must approach the head in the direction of the arrow. The data carriers can be read when static or even moving at relative speed in front of the read head, i. e. on moving past. As a result the system is suitable, for instance, for moving product carriers. The data carrier must always be static for writing. Features- Low-cost read/write system with predominantly used, separate read-only heads
- Extremely compact head design, no separate interface adapter required
- Read distance maximum 18 mm
- Dynamic reading with a relative speed up to 410 mm/s
- Data carrier memory capacity 16 bytes E2PROM read/write
- Easy connection of the read-only heads to I/O on any control system via 4-bit parallel interface (24 V)
- Read/write heads with serial interface RS232
|  |  | more information |
Find more information in our product catalog. |
 | Read-only head CIT3 with parallel interface, plugged in axially |
- Parallel interface
- Cylindrical design M30
- M12 plug connector
- Axial connection
Mounting instructionsOn mounting the read head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read head is observed. Attention:On the usage of a screened cable the connection cable is allowed to be max. 50 m long. Order numbers: | Read-only head CIT3 with parallel interface, plugged in axially Read-only head CIT3PL1N30-STA |
 | Read-only head CIT3 with parallel interface, plugged in radially |
- Parallel interface
- Cylindrical design M30
- M12 plug connector
- Radial connection
Order numbers: | Read-only head CIT3 with parallel interface, plugged in radially Read-only head CIT3PL1N30-STR |
 | Read/write head CIT3 G05 with serial interface |
- Serial interface RS232
- Active face can be adjusted to 5 different positions
- Standard housing according to EN 50041
- Connection terminals
Serial interfaceThe individual commands for reading and writing the data carrier are in accordance with the common 3964R protocol and are described in the EUCHNER CIS3 system manual (order no. 071 652). For data carrier programming away from the system, a convenient WINDOWS®-compatible PC software application is available (Software Transponder Coding, see page 41). Standard housingThe size of the robust housing in degree of protection IP65 is compliant with the standard EN 50041. The division into 3 assemblies permits easy mounting and straightforward replacement. Mounting instructionsOn mounting the read/write head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read/write head is observed. Attention:On the usage of a screened cable the connection cable for the serial interface is allowed to be max. 5 m long. Order numbers: | Read/write head CIT3 with serial interface Read/write head CIT3SX1R1G05KX |
Click on the product to view the available accessories!  | Read-only head CIT3 with parallel interface, plugged in axially |
Data Carrier Connection material - Connection cables with plug connector M12 for safety switch CES-A-C5.../CES-A-W5...
077 751 C-M12F08-08X025PV05,0-ZN-077751077 752 C-M12F08-08X025PV10,0-ZN-077752077 753 C-M12F08-08X025PV15,0-ZN-077753077 871 C-M12F08-08X025PV20,0-ZN-077871077 872 C-M12F08-08X025PV25,0-ZN-077872077 873 C-M12F08-08X025PV50,0-ZN-077873
 | Read-only head CIT3 with parallel interface, plugged in radially |
Data Carrier Connection material - Connection cables with plug connector M12 for safety switch CES-A-C5.../CES-A-W5...
077 751 C-M12F08-08X025PV05,0-ZN-077751077 752 C-M12F08-08X025PV10,0-ZN-077752077 753 C-M12F08-08X025PV15,0-ZN-077753077 871 C-M12F08-08X025PV20,0-ZN-077871077 872 C-M12F08-08X025PV25,0-ZN-077872077 873 C-M12F08-08X025PV50,0-ZN-077873
 | Read/write head CIT3 G05 with serial interface |
Data Carrier - Data carrier CIS3 horizontal
040 045 CIS3P35X16SH01KH084 746 CIS3P35X16SH16YHNOU - Data carrier CIS3 vertical
040 046 CIS3P35X16SH01KV095 950 CIS3P35X16SH16YVNOU - Data carrier CIS3 round
071 865 CIS3P16D08KH01K088 832 CIS3P16D08KH16YSNOU
Connection material - Connection cables with plug connector M12 for safety switch CES-A-C5.../CES-A-W5...
077 751 C-M12F08-08X025PV05,0-ZN-077751077 752 C-M12F08-08X025PV10,0-ZN-077752077 753 C-M12F08-08X025PV15,0-ZN-077753077 871 C-M12F08-08X025PV20,0-ZN-077871077 872 C-M12F08-08X025PV25,0-ZN-077872077 873 C-M12F08-08X025PV50,0-ZN-077873
 | Manuals |
| Title | Doc. nr. Edition Date | Languages | Document (Downloads) |
|---|
| System - Manual Inductive Read/Write Identsystem CIS3 | 067023 01 08/99 |  | 423 KB |  | 375 KB |
 | Catalogs |
| Title | Doc. nr. Edition Date | Languages | Document (Downloads) |
|---|
| Identsystem CIS | 076621 02 10/10 |  | 6083 KB | | Identification System CIS | 076660 02 10/10 |  | 6077 KB | | Système d'identification CIS | 110763 02 10/10 |  | 6089 KB |
|
|
|
|
|
|
|
|
|