The Identification System CIS3A is used if somewhat larger read distances are required. As a result a larger data carrier is necessary.

The data carrier is screwed on the product to be identified. The antenna and the interface electronics are fully integrated in the read heads and the read/write head. The data carrier and the head contain round-shaped antennae. The orientation of the data carrier in relation to the head is unimportant. This fact means that the data carrier can approach the head from any direction. The data carriers can be read when static or moving at low relative speed in front of the read head, i. e. on moving past. The data carrier must always be static for writing.

Features

  • Low-cost read/write system with predominantly used, separate read-only heads
  • Extremely compact head design, no separate interface adapter required
  • Read distance maximum 28 mm
  • Dynamic reading with a relative speed up to 230 mm/s
  • Data carrier memory capacity 16 bytes E2PROM read/write
  • Easy connection of the read-only heads to I/O on any control system via 4-bit parallel interface (24 V)
  • Read/write heads with serial interface RS232
Identification System CIS3A
+more information

Find more information in our product catalog.

+Read-only head CIT3A with parallel interface, plugged in axially
Read-only head CIT3A with parallel interface, plugged in axially

Attention:

On the usage of a screened cable the connection cable is allowed to be max. 50 m long.

Order numbers:

  • 071 900 CIT3APL1N30-STA
Read-only head CIT3A with parallel interface, plugged in axially
Dimension drawing
Terminal assignment
+Read-only head CIT3A G05 with parallel interface, plugged in axially
Read-only head CIT3A G05 with parallel interface, plugged in axially

Attention:

On the usage of a screened cable the connection cable is allowed to be max. 50 m long.

Order numbers:

  • 077 805 CIT3APL1G05ST
Read-only head CIT3A with parallel interface, plugged in axially
Dimension drawing
Terminal assignment
+Read/write head CIT3A G05 with serial interface
Read/write head CIT3A G05 with serial interface

Serial interface

The individual commands for reading and writing the data carrier are in accordance with the common 3964R protocol and are described in the EUCHNER CIS3 system manual (order no. 071 652). For data carrier programming away from the system, a convenient WINDOWS®-compatible PC software application is available (Software Transponder Coding).

Standard housing

The size of the robust housing in degree of protection IP65 is compliant with the standard EN 50041. The division into 3 assemblies permits easy mounting and straightforward replacement.

Attention:

On the usage of a screened cable the connection cable for the serial interface is allowed to be max. 5 m long.

Order numbers:

  • 077 890 CIT3ASX1R1G05KX
Read/write head CIT3A
Read/write head with serial interface V.24 / RS232
Terminal assignment

Click on the product to view the available accessories!

+Read-only head CIT3A with parallel interface, plugged in axially
Connection material
  • Connection cables with plug connector M12 for safety switch CES-A-C5.../CES-A-W5...
    077 751 C-M12F08-08X025PV05,0-ZN-077751
    077 752 C-M12F08-08X025PV10,0-ZN-077752
    077 753 C-M12F08-08X025PV15,0-ZN-077753
    077 871 C-M12F08-08X025PV20,0-ZN-077871
    077 872 C-M12F08-08X025PV25,0-ZN-077872
    077 873 C-M12F08-08X025PV50,0-ZN-077873
Data Carrier
+Read-only head CIT3A G05 with parallel interface, plugged in axially
Connection material
  • Connection cables with plug connector M12 for safety switch CES-A-C5.../CES-A-W5...
    077 751 C-M12F08-08X025PV05,0-ZN-077751
    077 752 C-M12F08-08X025PV10,0-ZN-077752
    077 753 C-M12F08-08X025PV15,0-ZN-077753
    077 871 C-M12F08-08X025PV20,0-ZN-077871
    077 872 C-M12F08-08X025PV25,0-ZN-077872
    077 873 C-M12F08-08X025PV50,0-ZN-077873
Data Carrier
+Read/write head CIT3A G05 with serial interface
Connection material
  • Connection cables with plug connector M12 for safety switch CES-A-C5.../CES-A-W5...
    077 751 C-M12F08-08X025PV05,0-ZN-077751
    077 752 C-M12F08-08X025PV10,0-ZN-077752
    077 753 C-M12F08-08X025PV15,0-ZN-077753
    077 871 C-M12F08-08X025PV20,0-ZN-077871
    077 872 C-M12F08-08X025PV25,0-ZN-077872
    077 873 C-M12F08-08X025PV50,0-ZN-077873
Data Carrier
  • Data carrier CIS3A
    071 711 CIS3AP50X50SH01K
    088 822 CIS3AP50X50SH16YSNOU
+Manuals
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
System - Manual Inductive Read/Write Identsystem CIS3067023
01
08/99
DEPDF 423 KB
ENPDF 375 KB
+Catalogs
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Identsystem CIS076621
02
10/10
DEPDF 6083 KB
Identification System CIS076660
02
10/10
ENPDF 6077 KB
Système d'identification CIS110763
02
10/10
FRPDF 6089 KB
+Declarations of conformity
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Title077155
06
PDF 273 KB
Search
+Search Tips:

Product search:

You can also look for parts of article descriptions. Example: NZ*538* or CES-AR*