Because of its slim design, the safety switch TX is excellent for mounting on the profiles of guard fences.

Features

  • Mechanical release from the front
  • 2 LEDs for function display
  • Large insertion funnel
  • Pulling the actuator does not prevent the switch from being released
  • 3 cable entries
  • Simple head changing
Safety switch TX
+more information

Find more information in our product catalog.

Connector Type: With Cable Entry
+Safety switch TX, release under load
  • Mechanical release on the front
  • Release under load possible
  • With door monitoring contact
Safety switch TX, release under load

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%
  • AC 110 V +10%, -15%

LED function display

The switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage.

Guard locking types

TX3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.

Switching elements

ETX BSlow-action switching contact 2 NC positive opening / 1 NO + 1 NC (door monitoring contact)
ETX CSlow-action switching contact 2 NC positive opening / 1 NO + 1 NO (door monitoring contact)

Order numbers:

  • 082 952 TX3B-A024M
  • 082 953 TX3C-A024M
  • 082 988 TX3B-A110M
  • 082 989 TX3C-A110M
  • 082 997 TX3B-A024N
  • 082 998 TX3C-A024N
Cable entry M20 x 1.5 / cable entry NPT ½"
Dimension drawing
Please order actuator separately
Wiring diagrams
Actuator inserted and locked
ETX B AC/DC 24 V
ETX C AC/DC 24 V
ETX B AC 110V/230V
ETX C AC 110V/230V
square_grey_light.eps
Solenoid monitoring
square_grey_dark.eps
Door monitoring
Switching functions TX
+Safety switch TX
  • Mechanical release on the front
  • With door monitoring contact
Safety switch TX

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%
  • AC 110 V +10%, -15%
  • AC 230 V +10%, -15%

LED function display

The switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage.

Guard locking types

TX1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.
TX2Open-circuit current principle, guard locking by applying voltage to the solenoid. Release by spring force.

Switching elements

ETX BSlow-action switching contact 2 NC positive opening / 1 NO + 1 NC (door monitoring contact)
ETX CSlow-action switching contact 2 NC positive opening / 1 NO + 1 NO (door monitoring contact)
ETX DSlow-action switching contact 2 NC positive opening + 2 NC positive opening (door monitoring contact)

Order numbers:

  • 082 921 TX1B-A024M
  • 082 922 TX1C-A024M
  • 082 927 TX2B-A024M
  • 082 928 TX2C-A024M
  • 085 383 TX1B-A110M
  • 085 384 TX1C-A110M
  • 085 385 TX1B-A230M
  • 085 386 TX1C-A230M
  • 085 387 TX2B-A110M
  • 085 388 TX2C-A110M
  • 085 389 TX2B-A230M
  • 085 390 TX2C-A230M
  • 095 025 TX1D-A024MC2081
  • 095 026 TX2D-A024MC2081
Cable entry M20 x 1.5
Dimension drawing
Please order actuator separately
Wiring diagrams
Actuator inserted and locked
ETX B
ETX C
ETX D
square_grey_light.eps
Solenoid monitoring
square_grey_dark.eps
Door monitoring
Switching functions TX
+Safety switch TX, escape release
  • Mechanical release on the front
  • Release under load possible (only TX3 version)
  • With door monitoring contact
Safety switch TX, escape release

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).

Escape release

Is used for the manual release of the guard locking from within the danger area without tools. With identification of On/Off position.

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

LED function display

The switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage.

Guard locking types

TX1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.
TX3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid. Release under load possible.

Switching elements

ETX BSlow-action switching contact 2 NC positive opening / 1 NO + 1 NC (door monitoring contact)
ETX CSlow-action switching contact 2 NC positive opening / 1 NO + 1 NO (door monitoring contact)
ETX DSlow-action switching contact 2 NC positive opening + 2 NC positive opening (door monitoring contact)

Order numbers:

  • 085 391 TX3B-A024MC1991
  • 093 118 TX3C-A024MC1991
  • 096 173 TX1D-A024MC1991
  • 098 946 TX3C-A024MC2161
  • 099 489 TX1C-A024MC2161
Cable entry M20 x 1.5
Dimension drawing
Please order actuator separately
Wiring diagrams
Actuator inserted and locked
ETX B AC/DC 24 V
ETX C AC/DC 24 V
ETX D AC/DC 24 V
square_grey_light.eps
Solenoid monitoring
square_grey_dark.eps
Door monitoring
Switching functions TX
Connector Type: M12
+Safety switch TX ASi, plug connector M12
Safety switch TX ASi, plug connector M12

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. To protect against tampering, the mechanical release is sealed with sealing lacquer.

Guard locking types

TX1Closed-circuit current principle, guard locking by spring force. Release by control of AS-i output 0.

Control of the guard locking solenoid

The guard locking solenoid is controlled by the control system via AS-Interface bus bit D0. In addition the 24V connection can be switched safely.

AS-Interface inputs

D0, D1Positively driven NC contact 1 (safety door monitor)
D2, D3Positively driven NC contact 2 (guard lock monitoring)

Evaluation is performed via a safety monitor.

AS-Interface outputs

D1LED red
D2Green LED

Internal LED function display

  • The Power LED indicates the operating voltage at the bus.
  • The LED LED indicates if a fault has been detected on the AS-Interface bus.

External LED function display

  • The green and the red LEDs can be optionally controlled with bits D1 and D2 by the control via the bus.

Order numbers:

  • 094 403 TX1B-A024SEM4AS1
Without escape release, plug connector M12
4-pin
Dimension drawing
Please order actuator separately
Connector assignment
+Safety switch TX ASi, plug connector M12
Safety switch TX ASi, plug connector M12

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. To protect against tampering, the mechanical release is sealed with sealing lacquer.

Escape release

Is used for the manual release of the guard locking from within the danger area without tools. With identification of On/Off position.

Guard locking types

TX1Closed-circuit current principle, guard locking by spring force. Release by control of AS-i output 0.

Control of the guard locking solenoid

The guard locking solenoid is controlled by the control system via AS-Interface bus bit D0. In addition the 24V connection can be switched safely.

AS-Interface inputs

D0, D1Positively driven NC contact 1 (safety door monitor)
D2, D3Positively driven NC contact 2 (guard lock monitoring)

Evaluation is performed via a safety monitor.

AS-Interface outputs

D1LED red
D2Green LED

Internal LED function display

  • The Power LED indicates the operating voltage at the bus.
  • The LED LED indicates if a fault has been detected on the AS-Interface bus.

External LED function display

  • The green and the red LEDs can be optionally controlled with bits D1 and D2 by the control via the bus.

Order numbers:

  • 095 914 TX1B-A024SEM4AS1C1991
Without escape release, plug connector M12
4-pin
Dimension drawing
Please order actuator separately
Connector assignment
+Safety switch TX, plug connector M12, direct connection to PROFIsafe
  • Mechanical release on the front
  • With door monitoring contact
  • Separate plug connector for solenoid monitoring and door monitoring with solenoid operating voltage
  • For direct connection to PROFIsafe inputs/outputs
Safety switch TX, plug connector M12, direct connection to PROFIsafe

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%
  • AC 110 V +10%, -15%
  • AC 230 V +10%, -15%

LED function display

The switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage.

Guard locking types

TX1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid. Release under load possible.
TX2Open-circuit current principle, guard locking by applying voltage to the solenoid. Release by spring force.

Switching elements

ETX BSlow-action switching contact 2 NC positive opening / 1 NO + 1 NC (door monitoring contact)

Order numbers:

  • 097 623 TX1B-A024MC2129
Plug connector M12
2 plug connectors, 5-pin
Dimension drawing
Please order actuator separately
Wiring diagrams
Actuator inserted and locked
ETX B
square_grey_light.eps
Solenoid monitoring
square_grey_dark.eps
Door monitoring
Switching functions TX
Connector Type: MR10
+Safety switch TX, plug connector BH10
  • Mechanical release on the front
  • With door monitoring contact
Safety switch TX, plug connector BH10

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

LED function display

The switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage.

Guard locking types

TX1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.
TX2Open-circuit current principle, guard locking by applying voltage to the solenoid. Release by spring force.

Switching elements

ETX BSlow-action switching contact 2 NC positive opening / 1 NO + 1 NC (door monitoring contact)
ETX CSlow-action switching contact 2 NC positive opening / 1 NO + 1 NO (door monitoring contact)

Order numbers:

  • 085 380 TX1B-A024BH10
  • 085 381 TX2B-A024BH10
Plug connector BH10
9-pin + PE
Dimension drawing
Please order actuator separately
Wiring diagrams
Actuator inserted and locked
ETX B
ETX C
square_grey_light.eps
Solenoid monitoring
square_grey_dark.eps
Door monitoring
Switching functions TX
Connector Type: MR12
+Safety switch TX, plug connector BH12, release under load
  • Mechanical release on the front
  • Release under load possible
  • With door monitoring contact
Safety switch TX, plug connector BH12, release under load

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

LED function display

The switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage.

Guard locking types

TX3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.

Switching elements

ETX BSlow-action switching contact 2 NC positive opening / 1 NO + 1 NC (door monitoring contact)
ETX CSlow-action switching contact 2 NC positive opening / 1 NO + 1 NO (door monitoring contact)

Order numbers:

  • 082 999 TX3B-A024BH12
  • 083 000 TX3C-A024BH12
Plug connector BH12
11-pin + PE
Dimension drawing
Please order actuator separately
Wiring diagrams
Actuator inserted and locked
ETX B
ETX C
square_grey_light.eps
Solenoid monitoring
square_grey_dark.eps
Door monitoring
Switching functions TX
Connector Type: RC18
+Safety switch TX, plug connector RC18
  • Mechanical release on the front
  • With door monitoring contact
Safety switch TX, plug connector RC18

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

LED function display

The switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage.

Guard locking types

TX1Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.
TX2Open-circuit current principle, guard locking by applying voltage to the solenoid. Release by spring force.

Switching elements

ETX BSlow-action switching contact 2 NC positive opening / 1 NO + 1 NC (door monitoring contact)
ETX CSlow-action switching contact 2 NC positive opening / 1 NO + 1 NO (door monitoring contact)

Order numbers:

  • 082 933 TX1B-A024RC18
  • 082 934 TX1C-A024RC18
  • 082 939 TX2B-A024RC18
  • 082 940 TX2C-A024RC18
Plug connector RC18
18-pin + PE
Dimension drawing
Please order actuator separately
Wiring diagrams
Actuator inserted and locked
ETX B
ETX C
square_grey_light.eps
Solenoid monitoring
square_grey_dark.eps
Door monitoring
Switching functions TX
+Safety switch TX, plug connector RC18, release under load
  • Mechanical release on the front
  • Release under load possible
  • With door monitoring contact
Safety switch TX, plug connector RC18, release under load

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

LED function display

The switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage.

Guard locking types

TX3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.

Switching elements

ETX BSlow-action switching contact 2 NC positive opening / 1 NO + 1 NC (door monitoring contact)
ETX CSlow-action switching contact 2 NC positive opening / 1 NO + 1 NO (door monitoring contact)

Order numbers:

  • 082 964 TX3B-A024RC18
  • 082 965 TX3C-A024RC18
Plug connector RC18
18-pin + PE
Dimension drawing
Please order actuator separately
Wiring diagrams
Actuator inserted and locked
ETX B
ETX C
square_grey_light.eps
Solenoid monitoring
square_grey_dark.eps
Door monitoring
Switching functions TX
+Safety switch TX, plug connector RC18
  • Mechanical release on the front
  • Release under load possible (only TX3 version)
  • With door monitoring contact
Safety switch TX, plug connector RC18

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).

Escape release

Is used for the manual release of the guard locking from within the danger area without tools. With identification of On/Off position.

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

LED function display

The switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage.

Guard locking types

TX3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid. Release under load possible.

Switching elements

ETX BSlow-action switching contact 2 NC positive opening / 1 NO + 1 NC (door monitoring contact)

Order numbers:

  • 093 559 TX3B-A024RC18C1991
Plug connector RC18
18-pin + PE
Dimension drawing
Please order actuator separately
Wiring diagrams
Actuator inserted and locked
ETX B
square_grey_light.eps
Solenoid monitoring
square_grey_dark.eps
Door monitoring
Switching functions TX
Connector Type: SR11
+Safety switch TX, plug connector SR11
  • Mechanical release on the front
  • Release under load possible
  • With door monitoring contact
Safety switch TX, plug connector SR11

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

LED function display

The switch has a function display (2 LEDs, red and green). The LED voltage is same as the solenoid operating voltage.

Guard locking types

TX3Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid.

Switching elements

ETX BSlow-action switching contact 2 NC positive opening / 1 NO + 1 NC (door monitoring contact)
ETX CSlow-action switching contact 2 NC positive opening / 1 NO + 1 NO (door monitoring contact)

Order numbers:

  • 085 396 TX3C-A024SR11
Plug connector SR11
11-pin + PE
Dimension drawing
Please order actuator separately
Wiring diagrams
Actuator inserted and locked
ETX B
ETX C
square_grey_light.eps
Solenoid monitoring
square_grey_dark.eps
Door monitoring
Switching functions TX

Click on the product to view the available accessories!

Connector Type: With Cable Entry
+Safety switch TX, release under load
Actuator
  • Bent actuator for safety switches NX/TX
    079 740 ACTUATOR-X-WQ
  • Actuator for safety switches NX/TX
    079 739 ACTUATOR-X-GQ
  • Actuator for safety switches NX/TX, increased overtravel
    079 741 ACTUATOR-X-GNQ
  • Bend actuator for safety switches NX/TX, increased overtravel
    079 742 ACTUATOR-X-WNQ
  • Hinged actuator left/right for safety switch NX/TX
    098 082 HINGED ACTUATOR-X-LR-N
  • Hinged actuator top/bottom for safety switch NX/TX
    097 906 HINGED ACTUATOR-X-OU-N
Bolt
  • Bolt TX-A/TX-C for safety switches TX and NX
    082 990 Bolt TX-A
    082 991 Bolt TX-C
Fastening
  • Mounting plates EMP-SB for safety switches TP...A, STA, STP and TX
    093 456 EMP-SB
  • Mounting plates EMP-B1 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 457 EMP-B1
  • Mounting plates EMP-B2 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 458 EMP-B2
Add-On
  • Lockout mechanism NX/TX
    096 098 Sperreinsatz TX
  • Emergency unlocking with manual return for safety switches TX
    094 771 Notentsperrung TX
  • Release with automatic reset for safety switch TX
    094 773 Entriegelung rückstellend TX
  • Lock for emergency unlocking with manual return for safety switches TX
    079 796 Schloss TX verschiedenschließend
    079 795 Schloss TX gleichschließend
+Safety switch TX
Actuator
  • Bent actuator for safety switches NX/TX
    079 740 ACTUATOR-X-WQ
  • Actuator for safety switches NX/TX
    079 739 ACTUATOR-X-GQ
  • Actuator for safety switches NX/TX, increased overtravel
    079 741 ACTUATOR-X-GNQ
  • Bend actuator for safety switches NX/TX, increased overtravel
    079 742 ACTUATOR-X-WNQ
  • Hinged actuator left/right for safety switch NX/TX
    098 082 HINGED ACTUATOR-X-LR-N
  • Hinged actuator top/bottom for safety switch NX/TX
    097 906 HINGED ACTUATOR-X-OU-N
Bolt
  • Bolt TX-A/TX-C for safety switches TX and NX
    082 990 Bolt TX-A
    082 991 Bolt TX-C
Fastening
  • Mounting plates EMP-SB for safety switches TP...A, STA, STP and TX
    093 456 EMP-SB
  • Mounting plates EMP-B1 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 457 EMP-B1
  • Mounting plates EMP-B2 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 458 EMP-B2
Add-On
  • Lockout mechanism NX/TX
    096 098 Sperreinsatz TX
  • Emergency unlocking with manual return for safety switches TX
    094 771 Notentsperrung TX
  • Release with automatic reset for safety switch TX
    094 773 Entriegelung rückstellend TX
  • Lock for emergency unlocking with manual return for safety switches TX
    079 796 Schloss TX verschiedenschließend
    079 795 Schloss TX gleichschließend
+Safety switch TX, escape release
Actuator
  • Bent actuator for safety switches NX/TX
    079 740 ACTUATOR-X-WQ
  • Actuator for safety switches NX/TX
    079 739 ACTUATOR-X-GQ
  • Actuator for safety switches NX/TX, increased overtravel
    079 741 ACTUATOR-X-GNQ
  • Bend actuator for safety switches NX/TX, increased overtravel
    079 742 ACTUATOR-X-WNQ
  • Hinged actuator left/right for safety switch NX/TX
    098 082 HINGED ACTUATOR-X-LR-N
  • Hinged actuator top/bottom for safety switch NX/TX
    097 906 HINGED ACTUATOR-X-OU-N
Bolt
  • Bolt TX-A/TX-C for safety switches TX and NX
    082 990 Bolt TX-A
    082 991 Bolt TX-C
Fastening
  • Mounting plates EMP-SB for safety switches TP...A, STA, STP and TX
    093 456 EMP-SB
  • Mounting plates EMP-B1 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 457 EMP-B1
  • Mounting plates EMP-B2 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 458 EMP-B2
Add-On
  • Lockout mechanism NX/TX
    096 098 Sperreinsatz TX
  • Emergency unlocking with manual return for safety switches TX
    094 771 Notentsperrung TX
  • Release with automatic reset for safety switch TX
    094 773 Entriegelung rückstellend TX
  • Lock for emergency unlocking with manual return for safety switches TX
    079 796 Schloss TX verschiedenschließend
    079 795 Schloss TX gleichschließend
Connector Type: M12
+Safety switch TX ASi, plug connector M12
Actuator
  • Bent actuator for safety switches NX/TX
    079 740 ACTUATOR-X-WQ
  • Actuator for safety switches NX/TX
    079 739 ACTUATOR-X-GQ
  • Actuator for safety switches NX/TX, increased overtravel
    079 741 ACTUATOR-X-GNQ
  • Bend actuator for safety switches NX/TX, increased overtravel
    079 742 ACTUATOR-X-WNQ
  • Hinged actuator left/right for safety switch NX/TX
    098 082 HINGED ACTUATOR-X-LR-N
  • Hinged actuator top/bottom for safety switch NX/TX
    097 906 HINGED ACTUATOR-X-OU-N
Bolt
  • Bolt TX-A/TX-C for safety switches TX and NX
    082 990 Bolt TX-A
    082 991 Bolt TX-C
Fastening
  • Mounting plates EMP-SB for safety switches TP...A, STA, STP and TX
    093 456 EMP-SB
  • Mounting plates EMP-B1 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 457 EMP-B1
  • Mounting plates EMP-B2 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 458 EMP-B2
Add-On
  • Lockout mechanism NX/TX
    096 098 Sperreinsatz TX
  • Emergency unlocking with manual return for safety switches TX
    094 771 Notentsperrung TX
  • Release with automatic reset for safety switch TX
    094 773 Entriegelung rückstellend TX
  • Lock for emergency unlocking with manual return for safety switches TX
    079 796 Schloss TX verschiedenschließend
    079 795 Schloss TX gleichschließend
+Safety switch TX ASi, plug connector M12
Actuator
  • Bent actuator for safety switches NX/TX
    079 740 ACTUATOR-X-WQ
  • Actuator for safety switches NX/TX
    079 739 ACTUATOR-X-GQ
  • Actuator for safety switches NX/TX, increased overtravel
    079 741 ACTUATOR-X-GNQ
  • Bend actuator for safety switches NX/TX, increased overtravel
    079 742 ACTUATOR-X-WNQ
  • Hinged actuator left/right for safety switch NX/TX
    098 082 HINGED ACTUATOR-X-LR-N
  • Hinged actuator top/bottom for safety switch NX/TX
    097 906 HINGED ACTUATOR-X-OU-N
Bolt
  • Bolt TX-AF/TX-CF with escape release for safety switch TX...C1991
    085 392 Bolt TX-AF
    085 393 Bolt TX-CF
Fastening
  • Mounting plates EMP-SB for safety switches TP...A, STA, STP and TX
    093 456 EMP-SB
  • Mounting plates EMP-B1 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 457 EMP-B1
  • Mounting plates EMP-B2 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 458 EMP-B2
Add-On
  • Lockout mechanism NX/TX
    096 098 Sperreinsatz TX
  • Emergency unlocking with manual return for safety switches TX
    094 771 Notentsperrung TX
  • Release with automatic reset for safety switch TX
    094 773 Entriegelung rückstellend TX
  • Lock for emergency unlocking with manual return for safety switches TX
    079 796 Schloss TX verschiedenschließend
    079 795 Schloss TX gleichschließend
+Safety switch TX, plug connector M12, direct connection to PROFIsafe
Actuator
  • Bent actuator for safety switches NX/TX
    079 740 ACTUATOR-X-WQ
  • Actuator for safety switches NX/TX
    079 739 ACTUATOR-X-GQ
  • Actuator for safety switches NX/TX, increased overtravel
    079 741 ACTUATOR-X-GNQ
  • Bend actuator for safety switches NX/TX, increased overtravel
    079 742 ACTUATOR-X-WNQ
  • Hinged actuator left/right for safety switch NX/TX
    098 082 HINGED ACTUATOR-X-LR-N
  • Hinged actuator top/bottom for safety switch NX/TX
    097 906 HINGED ACTUATOR-X-OU-N
Bolt
  • Bolt TX-A/TX-C for safety switches TX and NX
    082 990 Bolt TX-A
    082 991 Bolt TX-C
Fastening
  • Mounting plates EMP-SB for safety switches TP...A, STA, STP and TX
    093 456 EMP-SB
  • Mounting plates EMP-B1 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 457 EMP-B1
  • Mounting plates EMP-B2 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 458 EMP-B2
Add-On
  • Lockout mechanism NX/TX
    096 098 Sperreinsatz TX
  • Emergency unlocking with manual return for safety switches TX
    094 771 Notentsperrung TX
  • Release with automatic reset for safety switch TX
    094 773 Entriegelung rückstellend TX
  • Lock for emergency unlocking with manual return for safety switches TX
    079 796 Schloss TX verschiedenschließend
    079 795 Schloss TX gleichschließend
Connector Type: MR10
+Safety switch TX, plug connector BH10
Actuator
  • Bent actuator for safety switches NX/TX
    079 740 ACTUATOR-X-WQ
  • Actuator for safety switches NX/TX
    079 739 ACTUATOR-X-GQ
  • Actuator for safety switches NX/TX, increased overtravel
    079 741 ACTUATOR-X-GNQ
  • Bend actuator for safety switches NX/TX, increased overtravel
    079 742 ACTUATOR-X-WNQ
  • Hinged actuator left/right for safety switch NX/TX
    098 082 HINGED ACTUATOR-X-LR-N
  • Hinged actuator top/bottom for safety switch NX/TX
    097 906 HINGED ACTUATOR-X-OU-N
Bolt
  • Bolt TX-A/TX-C for safety switches TX and NX
    082 990 Bolt TX-A
    082 991 Bolt TX-C
Fastening
  • Mounting plates EMP-SB for safety switches TP...A, STA, STP and TX
    093 456 EMP-SB
  • Mounting plates EMP-B1 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 457 EMP-B1
  • Mounting plates EMP-B2 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 458 EMP-B2
Add-On
  • Lockout mechanism NX/TX
    096 098 Sperreinsatz TX
  • Emergency unlocking with manual return for safety switches TX
    094 771 Notentsperrung TX
  • Release with automatic reset for safety switch TX
    094 773 Entriegelung rückstellend TX
  • Lock for emergency unlocking with manual return for safety switches TX
    079 796 Schloss TX verschiedenschließend
    079 795 Schloss TX gleichschließend
Connector Type: MR12
+Safety switch TX, plug connector BH12, release under load
Actuator
  • Bent actuator for safety switches NX/TX
    079 740 ACTUATOR-X-WQ
  • Actuator for safety switches NX/TX
    079 739 ACTUATOR-X-GQ
  • Actuator for safety switches NX/TX, increased overtravel
    079 741 ACTUATOR-X-GNQ
  • Bend actuator for safety switches NX/TX, increased overtravel
    079 742 ACTUATOR-X-WNQ
  • Hinged actuator left/right for safety switch NX/TX
    098 082 HINGED ACTUATOR-X-LR-N
  • Hinged actuator top/bottom for safety switch NX/TX
    097 906 HINGED ACTUATOR-X-OU-N
Bolt
  • Bolt TX-A/TX-C for safety switches TX and NX
    082 990 Bolt TX-A
    082 991 Bolt TX-C
Fastening
  • Mounting plates EMP-SB for safety switches TP...A, STA, STP and TX
    093 456 EMP-SB
  • Mounting plates EMP-B1 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 457 EMP-B1
  • Mounting plates EMP-B2 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 458 EMP-B2
Add-On
  • Lockout mechanism NX/TX
    096 098 Sperreinsatz TX
  • Emergency unlocking with manual return for safety switches TX
    094 771 Notentsperrung TX
  • Release with automatic reset for safety switch TX
    094 773 Entriegelung rückstellend TX
  • Lock for emergency unlocking with manual return for safety switches TX
    079 796 Schloss TX verschiedenschließend
    079 795 Schloss TX gleichschließend
Connector Type: RC18
+Safety switch TX, plug connector RC18
Actuator
  • Bent actuator for safety switches NX/TX
    079 740 ACTUATOR-X-WQ
  • Actuator for safety switches NX/TX
    079 739 ACTUATOR-X-GQ
  • Actuator for safety switches NX/TX, increased overtravel
    079 741 ACTUATOR-X-GNQ
  • Bend actuator for safety switches NX/TX, increased overtravel
    079 742 ACTUATOR-X-WNQ
  • Hinged actuator left/right for safety switch NX/TX
    098 082 HINGED ACTUATOR-X-LR-N
  • Hinged actuator top/bottom for safety switch NX/TX
    097 906 HINGED ACTUATOR-X-OU-N
Bolt
  • Bolt TX-A/TX-C for safety switches TX and NX
    082 990 Bolt TX-A
    082 991 Bolt TX-C
Fastening
  • Mounting plates EMP-SB for safety switches TP...A, STA, STP and TX
    093 456 EMP-SB
  • Mounting plates EMP-B1 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 457 EMP-B1
  • Mounting plates EMP-B2 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 458 EMP-B2
Add-On
  • Lockout mechanism NX/TX
    096 098 Sperreinsatz TX
  • Emergency unlocking with manual return for safety switches TX
    094 771 Notentsperrung TX
  • Release with automatic reset for safety switch TX
    094 773 Entriegelung rückstellend TX
  • Lock for emergency unlocking with manual return for safety switches TX
    079 796 Schloss TX verschiedenschließend
    079 795 Schloss TX gleichschließend
+Safety switch TX, plug connector RC18, release under load
Actuator
  • Bent actuator for safety switches NX/TX
    079 740 ACTUATOR-X-WQ
  • Actuator for safety switches NX/TX
    079 739 ACTUATOR-X-GQ
  • Actuator for safety switches NX/TX, increased overtravel
    079 741 ACTUATOR-X-GNQ
  • Bend actuator for safety switches NX/TX, increased overtravel
    079 742 ACTUATOR-X-WNQ
  • Hinged actuator left/right for safety switch NX/TX
    098 082 HINGED ACTUATOR-X-LR-N
  • Hinged actuator top/bottom for safety switch NX/TX
    097 906 HINGED ACTUATOR-X-OU-N
Bolt
  • Bolt TX-A/TX-C for safety switches TX and NX
    082 990 Bolt TX-A
    082 991 Bolt TX-C
Fastening
  • Mounting plates EMP-SB for safety switches TP...A, STA, STP and TX
    093 456 EMP-SB
  • Mounting plates EMP-B1 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 457 EMP-B1
  • Mounting plates EMP-B2 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 458 EMP-B2
Add-On
  • Lockout mechanism NX/TX
    096 098 Sperreinsatz TX
  • Emergency unlocking with manual return for safety switches TX
    094 771 Notentsperrung TX
  • Release with automatic reset for safety switch TX
    094 773 Entriegelung rückstellend TX
  • Lock for emergency unlocking with manual return for safety switches TX
    079 796 Schloss TX verschiedenschließend
    079 795 Schloss TX gleichschließend
+Safety switch TX, plug connector RC18
Actuator
  • Bent actuator for safety switches NX/TX
    079 740 ACTUATOR-X-WQ
  • Actuator for safety switches NX/TX
    079 739 ACTUATOR-X-GQ
  • Actuator for safety switches NX/TX, increased overtravel
    079 741 ACTUATOR-X-GNQ
  • Bend actuator for safety switches NX/TX, increased overtravel
    079 742 ACTUATOR-X-WNQ
  • Hinged actuator left/right for safety switch NX/TX
    098 082 HINGED ACTUATOR-X-LR-N
  • Hinged actuator top/bottom for safety switch NX/TX
    097 906 HINGED ACTUATOR-X-OU-N
Bolt
  • Bolt TX-AF/TX-CF with escape release for safety switch TX...C1991
    085 392 Bolt TX-AF
    085 393 Bolt TX-CF
Fastening
  • Mounting plates EMP-SB for safety switches TP...A, STA, STP and TX
    093 456 EMP-SB
  • Mounting plates EMP-B1 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 457 EMP-B1
  • Mounting plates EMP-B2 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 458 EMP-B2
Add-On
  • Lockout mechanism NX/TX
    096 098 Sperreinsatz TX
  • Emergency unlocking with manual return for safety switches TX
    094 771 Notentsperrung TX
  • Release with automatic reset for safety switch TX
    094 773 Entriegelung rückstellend TX
  • Lock for emergency unlocking with manual return for safety switches TX
    079 796 Schloss TX verschiedenschließend
    079 795 Schloss TX gleichschließend
Connector Type: SR11
+Safety switch TX, plug connector SR11
Actuator
  • Bent actuator for safety switches NX/TX
    079 740 ACTUATOR-X-WQ
  • Actuator for safety switches NX/TX
    079 739 ACTUATOR-X-GQ
  • Actuator for safety switches NX/TX, increased overtravel
    079 741 ACTUATOR-X-GNQ
  • Bend actuator for safety switches NX/TX, increased overtravel
    079 742 ACTUATOR-X-WNQ
  • Hinged actuator left/right for safety switch NX/TX
    098 082 HINGED ACTUATOR-X-LR-N
  • Hinged actuator top/bottom for safety switch NX/TX
    097 906 HINGED ACTUATOR-X-OU-N
Bolt
  • Bolt TX-A/TX-C for safety switches TX and NX
    082 990 Bolt TX-A
    082 991 Bolt TX-C
Fastening
  • Mounting plates EMP-SB for safety switches TP...A, STA, STP and TX
    093 456 EMP-SB
  • Mounting plates EMP-B1 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 457 EMP-B1
  • Mounting plates EMP-B2 for actuators for safety switches TP...A, STA, STP, TX and TZ
    093 458 EMP-B2
Add-On
  • Lockout mechanism NX/TX
    096 098 Sperreinsatz TX
  • Emergency unlocking with manual return for safety switches TX
    094 771 Notentsperrung TX
  • Release with automatic reset for safety switch TX
    094 773 Entriegelung rückstellend TX
  • Lock for emergency unlocking with manual return for safety switches TX
    079 796 Schloss TX verschiedenschließend
    079 795 Schloss TX gleichschließend
+Manuals
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Operating Instructions Safety Switches TX...079777
05
06/11
DEENFR
IT
PDF 931 KB
Operating Instructions Safety Switches TX...AS1094632
04
10/11
DEENPDF 302 KB
+Catalogs
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Busfähige Sicherheitstechnik092164
07
08/11
DEPDF 4544 KB
Sicherheitsschalter mit Metallgehäuse100319
07
08/11
DEPDF 11788 KB
Safety Products with Integrated Bus Interface092332
07
08/11
ENPDF 4511 KB
Safety Switches with Metal Housing100369
07
08/11
ENPDF 11701 KB
Technique de sécurité compatible avec les bus112564
07
08/11
FRPDF 4593 KB
Interrupteurs de sécurité avec boîtier métallique 100676
07
08/11
FRPDF 11875 KB
Interruptores de seguridad con carcasa metálica104856
07
08/11
ESPDF 12558 KB
Finecorsa di sicurezza con custodia metallica102282
02
02/08
ITPDF 10016 KB
+Declarations of conformity
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Title077153
21
PDF 183 KB
Title111196
03
PDF 906 KB
+CAD data
Search
+Search Tips:

Product search:

You can also look for parts of article descriptions. Example: NZ*538* or CES-AR*

Document search:

Search directly with the six-digit order number or document number.