CES evaluation units combine transponder evaluation and a safety relay in one deviceThe CES evaluation units have two enable paths and monitoring outputs for each read head connected. Depending on the series, the devices have additional monitoring outputs as well as connections for a monitored Start button and feedback loop. Start buttonEvaluation units with a connection for a Start button permit a monitored, manual start. The relay is started by actuating a button. The button is monitored for jamming or possible tampering (monitoring of the falling edge). Prior to starting the evaluation unit, the safe state of the safety components connected must be re-established. Feedback loopComponents connected downstream of the safety relay can be monitored for correct function. For this purpose normally closed contacts on these components are integrated into the feedback loop on the evaluation unit. Unicode evaluation unitsWith the unicode version, the actuators must be taught-in on the evaluation unit. During teach-in the actuator code is assigned to the evaluation unit. This code is saved in the evaluation unit. Whenever an actuator is read, the evaluation unit compares the code just read with the code saved. Only if the two bit patterns are identical, the actuator is recognized and the enable paths are closed. The number of possible teach-in operations is dependent of the evaluation unit used. Only the last actuator taught-in is detected. The unicode principle provides a high level of protection against tampering. Multicode evaluation unitsUnlike systems with unique code detection, with multicode evaluation units a specific actuator code is not requested, instead it is only checked whether the actuator is of a type from EUCHNER that can be detected by the system (multicode detection). There is no exact comparison of the actuator code with the code saved in the evaluation unit. As a result a teach-in operation is not necessary. |
 | Evaluation unit CES-A-ABA.../CES-A-UBA... (for 1 read head) |
- 1 read head can be connected
- 2 safety contacts (relay contacts)
- 1 internal normally open contact per safety contact
- Unicode and multicode evaluation unit
- Category 3 / PL e according to EN ISO 13849-1
Unicode evaluation unitEach actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Max. 8 actuators can be taught-in. Only the last actuator taught-in is detected. Multicode evaluation unitEvery suitable actuator is detected by the evaluation unit. Category according to EN ISO 13849-1Due to two redundant relay outputs (safety outputs) with internally monitored contacts, suitable for: - Category 3 / PL e according to EN ISO 13849-1
To achieve the stated category, both safety contacts must always be evaluated. Operating distanceThe standard version of the evaluation unit (CES-A-…-01B) has a large operating distance that, e. g., permits larger tolerances in the alignment of read head and actuator. Wherever a smaller operating distance is required, the version with reduced operating distance (CES-A-…-01) can be used. | TST | Input for self-test | | OUT | Monitoring output (semiconductor) | | ERR | Diagnostics output | | GND | Connected internally to 0V (not for high currents) |
Order numbers:Unicode - 071 850 CES-A-ABA-01
- 083 513 CES-A-ABA-01B
Multicode - 096 960 CES-A-UBA-01
- 096 961 CES-A-UBA-01B
| Evaluation unit CES-A-ABA.../CES-A-UBA... |
 | Evaluation unit CES-A-ABA... ATEX (for 1 read head) |
- 1 read head can be connected
- 2 safety contacts (relay contacts)
- 1 internal normally open contact per safety contact
- Unicode evaluation unit
- Category 3 / PL e according to EN ISO 13849-1
Unicode evaluation unitEach actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Max. 8 actuators can be taught-in. Only the last actuator taught-in is detected. Category according to EN ISO 13849-1Due to two redundant relay outputs (safety outputs) with internally monitored contacts, suitable for: - Category 3 / PL e according to EN ISO 13849-1
To achieve the stated category, both safety contacts must always be evaluated. ATEX ratingOperating distanceThe standard version of the evaluation unit (CES-A-…-01B) has a large operating distance that, e. g., permits larger tolerances in the alignment of read head and actuator. | TST | Input for self-test | | OUT | Monitoring output (semiconductor) | | ERR | Diagnostics output | | GND | Connected internally to 0V (not for high currents) |
Order numbers:Unicode | Evaluation unit CES-A-ABA... |
 | Evaluation unit CES-A-AEA-02B/CES-A-UEA-02B (for 2 read heads) |
- 2 read heads can be connected
- 2 safety contacts (relay contacts)
- 1 internal normally open contact per safety contact
- Start button and feedback loop can be connected
- Unicode and multicode evaluation unit
- Category 4 / PL e according to EN ISO 13849-1
Unicode evaluation unitEach actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Max. 8 actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught-in by fitting a jumper. Multicode evaluation unitEvery suitable actuator is detected by the evaluation unit. Category according to EN ISO 13849-1Due to two redundant relay outputs (safety outputs) with internally monitored contacts, suitable for: - Category 4 / PL e according to EN ISO 13849-1
Operating distanceThe evaluation unit has the standard operating distance that, e. g., permits larger tolerances in the alignment of read head and actuator. | TST | Input for self-test | | DIA | Diagnostics output | | O1,O2 | Monitoring outputs (semiconductor) | | Y1,Y2 | Feedback loop | | S | Start button connection |
Order numbers:Unicode Multicode | Evaluation unit CES-A-AEA-02B/CES-A-UEA-02B |
 | Evaluation unit CES-A-AEA-04B/CES-A-UEA-04B (for 4 read heads) |
- 4 read heads can be connected
- 2 safety contacts (relay contacts)
- 1 internal normally open contact per safety contact
- Start button and feedback loop can be connected
- Unicode and multicode evaluation unit
- Category 4 / PL e according to EN ISO 13849-1
Unicode evaluation unitEach actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught-in by fitting a jumper. Multicode evaluation unitEvery suitable actuator is detected by the evaluation unit. Category according to EN ISO 13849-1Due to two redundant relay outputs (safety outputs) with internally monitored contacts, suitable for: - Category 4 / PL e according to EN ISO 13849-1
Operating distanceThe evaluation unit has the standard operating distance that, e. g., permits larger tolerances in the alignment of read head and actuator. | TST | Input for self-test | | DIA | Diagnostics output | | O1...O4 | Monitoring outputs (semiconductor) | | Y1,Y2 | Feedback loop | | S | Start button connection |
Order numbers:Unicode Multicode | Evaluation unit CES-A-AEA-04B/CES-A-UEA-04B |
 | Evaluation unit CES-A-.1B-01B-AS1 for connection to AS-Interface (for 1 read head) |
- Evaluation unit for direct connection of a CES read head
- Connection of a CEM solenoid
- LED diagnostic displays
- Connection of CET guard locking
Connection of a read head CESThe CES series read head can be connected to the evaluation unit using an M12 plug connector. The read head is not included with the evaluation unit. Connection of a read head CEM or CETThe read heads are connected using two M12 plug connectors. Connection cables with M12 plug connectors are required for the evaluation unit, and connection cables with M8 plug connectors are needed for the read head. Connection cables and read head are not included with the evaluation unit.
Note: The separate auxiliary power must also be connected. versions| Unicode: | Only the actuator that undergoes a teach-in operation in the device is recognized. | | Multicode: | All EUCHNER actuators are recognized without a teach-in operation. |
ActuatorAn actuator with programmed code to suit the read head selected is needed. AS-Interface inputs| D0 - D3 | Input IN for read head |
Evaluation is performed via a safety monitor. AS-Interface outputs| D0 | Output OUT to control CEM or CET |
Operating principleThe non-contact safety systems CES operate on the basis of a uniquely electronically coded actuator (transponder). The transponder (actuator) receives and processes the electromagnetic field from a transceiver (read head), and the data signals are then sent back to the read head as a response depending on the transponder coding. Power is supplied and data transmitted to the coded actuator by induction using a read head. Order numbers:Unicode - 094 230 CES-A-F1B-01B-AS1
Multicode - 096 631 CES-A-V1B-01B-AS1
| Evaluation unit CES-A-.1B-01B-AS1 |
 | Evaluation unit CES-A-.1B-04B-AS1 for connection to AS-Interface (for 4 read heads) |
- Evaluation unit for connection of up to four CES read heads
- LED diagnostic displays
Connection of a read head CESThe CES series read head can be connected to the evaluation unit using an M12 plug connector. The read heads are not included with the evaluation unit. Connection of a read head CEM or CETAn additional standard AS-Interface module with outputs (DO) is required for connection of these read heads. versions| Unicode: | Only the actuator that undergoes a teach-in operation in the device is recognized. | | Multicode: | All EUCHNER actuators are recognized without a teach-in operation. |
ActuatorAn actuator with programmed code to suit the read head selected is needed. AS-Interface inputs| D0 - D3 | Input IN for CES read head |
Evaluation is performed via a safety monitor. Operating principleThe non-contact safety systems CES operate on the basis of a uniquely electronically coded actuator (transponder). The transponder (actuator) receives and processes the electromagnetic field from a transceiver (read head), and the data signals are then sent back to the read head as a response depending on the transponder coding. Power is supplied and data transmitted to the coded actuator by induction using a read head. Order numbers:Unicode - 097 660 CES-A-F1B-04B-AS1
Multicode - 100 206 CES-A-V1B-04B-AS1
| Evaluation unit CES-A-F1B-04B-AS1 |
Click on the product to view the available accessories!  | Evaluation unit CES-A-ABA.../CES-A-UBA... (for 1 read head) |
Readhead - Read head CES-A-LNA..., hard-wired encapsulated cable, PVC
071 845 CES-A-LNA-05V071 846 CES-A-LNA-10V071 847 CES-A-LNA-15V071 975 CES-A-LNA-25V - Read head CES-A-LNA..., hard-wired encapsulated cable, PUR
077 806 CES-A-LNA-05P077 807 CES-A-LNA-10P084 682 CES-A-LNA-15P - Read head CES-A-LNA-SC, M8 plug connector
- Read head CES-A-LCA..., hard-wired encapsulated cable, PVC
- Read head CES-A-LQA-SC, M8 plug connector
- Read head CES-A-LMN-SC, M8 plug connector
- Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
- Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
 | Evaluation unit CES-A-ABA... ATEX (for 1 read head) |
Readhead - Read head CES-A-LNA-SC-EX, M8 plug connector
- Read head CES-A-LMN-SC-EX, M8 plug connector
- Read head CEM-A-LE05...-EX with guard locking without guard lock monitoring with remanence
097 174 CEM-A-LE05K-S2-EX
 | Evaluation unit CES-A-AEA-02B/CES-A-UEA-02B (for 2 read heads) |
Readhead - Read head CES-A-LNA..., hard-wired encapsulated cable, PVC
071 845 CES-A-LNA-05V071 846 CES-A-LNA-10V071 847 CES-A-LNA-15V071 975 CES-A-LNA-25V - Read head CES-A-LNA..., hard-wired encapsulated cable, PUR
077 806 CES-A-LNA-05P077 807 CES-A-LNA-10P084 682 CES-A-LNA-15P - Read head CES-A-LNA-SC, M8 plug connector
- Read head CES-A-LCA..., hard-wired encapsulated cable, PVC
- Read head CES-A-LQA-SC, M8 plug connector
- Read head CES-A-LMN-SC, M8 plug connector
- Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
- Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
 | Evaluation unit CES-A-AEA-04B/CES-A-UEA-04B (for 4 read heads) |
Readhead - Read head CES-A-LNA..., hard-wired encapsulated cable, PVC
071 845 CES-A-LNA-05V071 846 CES-A-LNA-10V071 847 CES-A-LNA-15V071 975 CES-A-LNA-25V - Read head CES-A-LNA..., hard-wired encapsulated cable, PUR
077 806 CES-A-LNA-05P077 807 CES-A-LNA-10P084 682 CES-A-LNA-15P - Read head CES-A-LNA-SC, M8 plug connector
- Read head CES-A-LCA..., hard-wired encapsulated cable, PVC
- Read head CES-A-LQA-SC, M8 plug connector
- Read head CES-A-LMN-SC, M8 plug connector
- Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
- Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
 | Evaluation unit CES-A-.1B-01B-AS1 for connection to AS-Interface (for 1 read head) |
Readhead - Read head CES-A-LNA..., hard-wired encapsulated cable, PVC
071 845 CES-A-LNA-05V071 846 CES-A-LNA-10V071 847 CES-A-LNA-15V071 975 CES-A-LNA-25V - Read head CES-A-LNA..., hard-wired encapsulated cable, PUR
077 806 CES-A-LNA-05P077 807 CES-A-LNA-10P084 682 CES-A-LNA-15P - Read head CES-A-LNA-SC, M8 plug connector
- Read head CES-A-LCA..., hard-wired encapsulated cable, PVC
- Read head CES-A-LQA-SC, M8 plug connector
- Read head CES-A-LMN-SC, M8 plug connector
- Read head CES-A-LNA...-AS1
094 031 CES-A-LNA-01V-AS1094 032 CES-A-LNA-02V-AS1 - Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
- Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
 | Evaluation unit CES-A-.1B-04B-AS1 for connection to AS-Interface (for 4 read heads) |
Readhead - Read head CES-A-LNA..., hard-wired encapsulated cable, PVC
071 845 CES-A-LNA-05V071 846 CES-A-LNA-10V071 847 CES-A-LNA-15V071 975 CES-A-LNA-25V - Read head CES-A-LNA..., hard-wired encapsulated cable, PUR
077 806 CES-A-LNA-05P077 807 CES-A-LNA-10P084 682 CES-A-LNA-15P - Read head CES-A-LNA-SC, M8 plug connector
- Read head CES-A-LCA..., hard-wired encapsulated cable, PVC
- Read head CES-A-LQA-SC, M8 plug connector
- Read head CES-A-LMN-SC, M8 plug connector
- Read head CES-A-LNA...-AS1
094 031 CES-A-LNA-01V-AS1094 032 CES-A-LNA-02V-AS1 - Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
- Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
 | Manuals |
 | Catalogs |
| Title | Doc. nr. Edition Date | Languages | Document (Downloads) |
|---|
| Busfähige Sicherheitstechnik | 092164 07 08/11 |  | 4544 KB | | Safety Products with Integrated Bus Interface | 092332 07 08/11 |  | 4511 KB | | Technique de sécurité compatible avec les bus | 112564 07 08/11 |  | 4593 KB |
 | CAD data |
|
|
|
|
|