CES evaluation units combine transponder evaluation and a safety relay in one deviceThe CES evaluation units have two enable paths and monitoring outputs for each read head connected. Depending on the series, the devices have additional monitoring outputs as well as connections for a monitored Start button and feedback loop. Start buttonEvaluation units with a connection for a Start button permit a monitored, manual start. The relay is started by actuating a button. The button is monitored for jamming or possible tampering (monitoring of the falling edge). Prior to starting the evaluation unit, the safe state of the safety components connected must be re-established. Feedback loopComponents connected downstream of the safety relay can be monitored for correct function. For this purpose normally closed contacts on these components are integrated into the feedback loop on the evaluation unit. Unicode evaluation unitsWith the unicode version, the actuators must be taught-in on the evaluation unit. During teach-in the actuator code is assigned to the evaluation unit. This code is saved in the evaluation unit. Whenever an actuator is read, the evaluation unit compares the code just read with the code saved. Only if the two bit patterns are identical, the actuator is recognized and the enable paths are closed. The number of possible teach-in operations is dependent of the evaluation unit used. Only the last actuator taught-in is detected. The unicode principle provides a high level of protection against tampering. Multicode evaluation unitsUnlike systems with unique code detection, with multicode evaluation units a specific actuator code is not requested, instead it is only checked whether the actuator is of a type from EUCHNER that can be detected by the system (multicode detection). There is no exact comparison of the actuator code with the code saved in the evaluation unit. As a result a teach-in operation is not necessary. Guard lock monitoring with the safety system CES-AZIn principle a read head with guard locking can be connected to each CES evaluation unit with standard read distance. Evaluation units in the system family CES-AZ-… monitor the guard locking function in accordance with EN 1088. For information on which device combination can be used as guard locking in accordance with EN 1088, please refer to the related product page and the combination tables. Evaluation units in the system family CES-A-… do not provide safe guard lock monitoring. |
 | Evaluation unit CES-AZ-AES-01B/ CES-AZ-UES-01B (for 1 read head) |
- 1 read head can be connected
- 2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
- Start button and feedback loop can be connected
- Plug-in connection terminals
- Category 4 / PL e according to EN ISO 13849-1
Unicode evaluationEach actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught-in by fitting a jumper. Multicode evaluationEvery suitable actuator is detected by the evaluation unit. Guard lock monitoringEvaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories Category according to EN ISO 13849-1Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for: - Category 4 / PL e according to EN ISO 13849-1
Each safety path is independently safe. LED indicator| STATE | Status LED | | DIA | Diagnostics LED | | OUT | Safety output status |
Additional connections| TST | Input for self-test | | O1 | Monitoring output (semiconductor) | | DIA | Diagnostics output | | Y1, Y2 | Feedback loop | | S | Start button connection (monitoring of the falling edge) |
Important:The plug-in connection terminals are not included and must be ordered separately. Order numbers:Unicode Multicode | Evaluation unit CES-AZ-AES-01B/ CES-AZ-UES-01B |
 | Evaluation unit CES-AZ-AES-01B ATEX (for 1 read head) |
- 1 read head can be connected
- 2 safety contacts (relay contacts) with 2 internally connected NO contacts per output)
- Plug-in connection terminals
- Start button and feedback loop can be connected
- Reset button
- Category 4 /PL e according to EN 13849-1
Unicode evaluationEach actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught-in by fitting a jumper. Guard lock monitoringEvaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories Category according to EN 13849-1Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for: - Category 4 /PL e according to EN 13849-1
Each safety path is independently safe. Operating distanceThe evaluation unit has the standard operating distance that, e. g., permits larger tolerances in the alignment of read head and actuator. LED indicator| STATE | Status LED | | DIA | Diagnostics LED | | OUT | Safety output status |
Additional connections| TST | Input for self-test | | O1 | Monitoring output (semiconductor) | | DIA | Diagnostics output | | Y1, Y2 | Feedback loop | | S | Start button connection (monitoring of the falling edge) |
ATEX ratingOrder numbers:Unicode - 105 142 CES-AZ-AES-01B-EX
Multicode - 106 724 CES-AZ-UES-01B-EX
| Evaluation unit CES-AZ-AES-01B |
 | Evaluation unit CES-AZ-AES-02B/ CES-AZ-UES-02B (for 2 read heads) |
- 2 read heads can be connected
- 2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
- Start button and feedback loop can be connected
- Plug-in connection terminals
- Category 4 / PL e according to EN ISO 13849-1
Unicode evaluationEach actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught-in by fitting a jumper. Multicode evaluationEvery suitable actuator is detected by the evaluation unit. Guard lock monitoringEvaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories Category according to EN ISO 13849-1Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for: - Category 4 / PL e according to EN ISO 13849-1
Each safety path is independently safe. LED indicator| STATE | Status LED | | DIA | Diagnostics LED | | OUT | Safety output status |
Additional connections| TST | Input for self-test | | O1, O2 | Monitoring outputs (semiconductor) | | DIA | Diagnostics output | | Y1, Y2 | Feedback loop | | S | Start button connection (monitoring of the falling edge) |
Important:The plug-in connection terminals are not included and must be ordered separately. Order numbers:Unicode Multicode | Evaluation unit CES-AZ-AES-02B/ CES-AZ-UES-02B |
 | Evaluation unit CES-AZ-AES-04B/ CES-AZ-UES-04B (for 4 read heads) |
- 4 read heads can be connected
- 2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
- Start button and feedback loop can be connected
- Plug-in connection terminals
- Category 4 / PL e according to EN ISO 13849-1
Unicode evaluationEach actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught-in by fitting a jumper. Multicode evaluationEvery suitable actuator is detected by the evaluation unit. Guard lock monitoringEvaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories Category according to EN ISO 13849-1Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for: - Category 4 / PL e according to EN ISO 13849-1
Each safety path is independently safe. LED indicator| STATE | Status LED | | DIA | Diagnostics LED | | OUT | Safety output status |
Additional connections| TST | Input for self-test | | O1 ... O4 | Monitoring outputs (semiconductor) | | DIA | Diagnostics output | | Y1, Y2 | Feedback loop | | S | Start button connection (monitoring of the falling edge) |
Important:The plug-in connection terminals are not included and must be ordered separately. Order numbers:Unicode Multicode | Evaluation unit CES-AZ-AES-04B/ CES-AZ-UES-04B |
 | Evaluation unit CES-AZ-ABS.../-UBS... (replaced by CES-AZ-AES.../-UES...) |
Important:For new projects use if possible the devices: - CES-AZ-AES-01B (104 770)
- CES-AZ-UES-01B (105 139)
Unicode evaluation unitEach actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Max. 8 actuators can be taught-in. Only the last actuator taught-in is detected. Multicode evaluation unitEvery suitable actuator is detected by the evaluation unit. Guard lock monitoringEvaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories Category according to EN ISO 13849-1Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for: - Category 3 / PL e according to EN ISO 13849-1
Each safety path is independently safe. Operating distanceThe evaluation unit has the standard operating distance that, e. g., permits larger tolerances in the alignment of read head and actuator. Additional connections| TST | Input for self-test | | OUT | Monitoring output (semiconductor) | | ERR | Diagnostics output | | GND | Connected internally to 0V (not for high currents) |
Important: The plug-in connection terminals are not included and must be ordered separately. Order numbers:Unicode Multicode | Evaluation unit CES-AZ-ABS.../CES-AZ-UBS... |
Click on the product to view the available accessories!  | Evaluation unit CES-AZ-AES-01B/ CES-AZ-UES-01B (for 1 read head) |
Readhead - Read head CES-A-LNA..., hard-wired encapsulated cable, PVC
071 845 CES-A-LNA-05V071 846 CES-A-LNA-10V071 847 CES-A-LNA-15V071 975 CES-A-LNA-25V - Read head CES-A-LNA..., hard-wired encapsulated cable, PUR
077 806 CES-A-LNA-05P077 807 CES-A-LNA-10P084 682 CES-A-LNA-15P - Read head CES-A-LNA-SC, M8 plug connector
- Read head CES-A-LCA..., hard-wired encapsulated cable, PVC
- Read head CES-A-LQA-SC, M8 plug connector
- Read head CES-A-LMN-SC, M8 plug connector
- Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
- Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
- Read head CET1-AX-..., M12, with guard locking and guard lock monitoring
095 735 CET1-AX-LRA-00-50X-SA - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, 2 freely configurable LEDs
104 062 CET1-AX-LRA-00-50L-SA - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, double insertion slide
100 399 CET1-AX-LDA-00-50X-SE - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release
102 161 CET1-AX-LRA-00-50F-SA - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release, double insertion slide
103 750 CET1-AX-LDA-00-50F-SA - Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring
102 988 CET1-AX-LRA-00-50X-SC - Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring, double insertion slide
103 444 CET1-AX-LDA-00-50X-SC - Read head CES-A-LSP-..., hard-wired encapsulated cable, PVC
104 966 CES-A-LSP-05V-104966104 967 CES-A-LSP-10V-104967106 271 CES-A-LSP-15V-106271106 272 CES-A-LSP-20V-106272104 968 CES-A-LSP-25V-104968 - Read head CES-A-LSP-SB..., plug connector M5
104 969 CES-A-LSP-SB-104969 - Read head CES-A-LNN-...
106 602 CES-A-LNN-05V-106602 - Read head CES-A-LNN-SC...
106 601 CES-A-LNN-SC-106601
Connection material - Connection set for evaluation unit CES-AZ-.ES-01B
104 756 CES-EA-TC-AK04-104756
 | Evaluation unit CES-AZ-AES-01B ATEX (for 1 read head) |
Readhead - Read head CES-A-LNA-SC-EX, M8 plug connector
- Read head CES-A-LMN-SC-EX, M8 plug connector
- Read head CEM-A-LE05...-EX with guard locking without guard lock monitoring with remanence
097 174 CEM-A-LE05K-S2-EX
Connection material - Connection set for evaluation unit CES-AZ-.ES-01B
104 756 CES-EA-TC-AK04-104756
 | Evaluation unit CES-AZ-AES-02B/ CES-AZ-UES-02B (for 2 read heads) |
Readhead - Read head CES-A-LNA..., hard-wired encapsulated cable, PVC
071 845 CES-A-LNA-05V071 846 CES-A-LNA-10V071 847 CES-A-LNA-15V071 975 CES-A-LNA-25V - Read head CES-A-LNA..., hard-wired encapsulated cable, PUR
077 806 CES-A-LNA-05P077 807 CES-A-LNA-10P084 682 CES-A-LNA-15P - Read head CES-A-LNA-SC, M8 plug connector
- Read head CES-A-LCA..., hard-wired encapsulated cable, PVC
- Read head CES-A-LQA-SC, M8 plug connector
- Read head CES-A-LMN-SC, M8 plug connector
- Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
- Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
- Read head CET1-AX-..., M12, with guard locking and guard lock monitoring
095 735 CET1-AX-LRA-00-50X-SA - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, 2 freely configurable LEDs
104 062 CET1-AX-LRA-00-50L-SA - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, double insertion slide
100 399 CET1-AX-LDA-00-50X-SE - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release
102 161 CET1-AX-LRA-00-50F-SA - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release, double insertion slide
103 750 CET1-AX-LDA-00-50F-SA - Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring
102 988 CET1-AX-LRA-00-50X-SC - Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring, double insertion slide
103 444 CET1-AX-LDA-00-50X-SC - Read head CES-A-LSP-..., hard-wired encapsulated cable, PVC
104 966 CES-A-LSP-05V-104966104 967 CES-A-LSP-10V-104967106 271 CES-A-LSP-15V-106271106 272 CES-A-LSP-20V-106272104 968 CES-A-LSP-25V-104968 - Read head CES-A-LSP-SB..., plug connector M5
104 969 CES-A-LSP-SB-104969 - Read head CES-A-LNN-...
106 602 CES-A-LNN-05V-106602 - Read head CES-A-LNN-SC...
106 601 CES-A-LNN-SC-106601
Connection material - Connection set for evaluation unit CES-AZ-.ES-02B
104 771 CES-EA-TC-AK06-104771
 | Evaluation unit CES-AZ-AES-04B/ CES-AZ-UES-04B (for 4 read heads) |
Readhead - Read head CES-A-LNA..., hard-wired encapsulated cable, PVC
071 845 CES-A-LNA-05V071 846 CES-A-LNA-10V071 847 CES-A-LNA-15V071 975 CES-A-LNA-25V - Read head CES-A-LNA..., hard-wired encapsulated cable, PUR
077 806 CES-A-LNA-05P077 807 CES-A-LNA-10P084 682 CES-A-LNA-15P - Read head CES-A-LNA-SC, M8 plug connector
- Read head CES-A-LCA..., hard-wired encapsulated cable, PVC
- Read head CES-A-LQA-SC, M8 plug connector
- Read head CES-A-LMN-SC, M8 plug connector
- Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
- Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
- Read head CET1-AX-..., M12, with guard locking and guard lock monitoring
095 735 CET1-AX-LRA-00-50X-SA - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, 2 freely configurable LEDs
104 062 CET1-AX-LRA-00-50L-SA - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, double insertion slide
100 399 CET1-AX-LDA-00-50X-SE - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release
102 161 CET1-AX-LRA-00-50F-SA - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release, double insertion slide
103 750 CET1-AX-LDA-00-50F-SA - Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring
102 988 CET1-AX-LRA-00-50X-SC - Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring, double insertion slide
103 444 CET1-AX-LDA-00-50X-SC - Read head CES-A-LSP-..., hard-wired encapsulated cable, PVC
104 966 CES-A-LSP-05V-104966104 967 CES-A-LSP-10V-104967106 271 CES-A-LSP-15V-106271106 272 CES-A-LSP-20V-106272104 968 CES-A-LSP-25V-104968 - Read head CES-A-LSP-SB..., plug connector M5
104 969 CES-A-LSP-SB-104969 - Read head CES-A-LNN-...
106 602 CES-A-LNN-05V-106602 - Read head CES-A-LNN-SC...
106 601 CES-A-LNN-SC-106601
Connection material - Connection kit for evaluation unit CES-AZ-.ES-04B and CES-AR-AES-12
104 776 CES-EA-TC-AK08-104776 - Connection kit for evaluation unit CES-AR-AES-12
112 629 CES-EA-TC-KK08-112629
 | Evaluation unit CES-AZ-ABS.../-UBS... (replaced by CES-AZ-AES.../-UES...) |
Readhead - Read head CES-A-LNA..., hard-wired encapsulated cable, PVC
071 845 CES-A-LNA-05V071 846 CES-A-LNA-10V071 847 CES-A-LNA-15V071 975 CES-A-LNA-25V - Read head CES-A-LNA..., hard-wired encapsulated cable, PUR
077 806 CES-A-LNA-05P077 807 CES-A-LNA-10P084 682 CES-A-LNA-15P - Read head CES-A-LNA-SC, M8 plug connector
- Read head CES-A-LCA..., hard-wired encapsulated cable, PVC
- Read head CES-A-LQA-SC, M8 plug connector
- Read head CES-A-LMN-SC, M8 plug connector
- Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
- Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
- Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
- Read head CET1-AX-..., M12, with guard locking and guard lock monitoring
095 735 CET1-AX-LRA-00-50X-SA - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, 2 freely configurable LEDs
104 062 CET1-AX-LRA-00-50L-SA - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, double insertion slide
100 399 CET1-AX-LDA-00-50X-SE - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release
102 161 CET1-AX-LRA-00-50F-SA - Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release, double insertion slide
103 750 CET1-AX-LDA-00-50F-SA - Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring
102 988 CET1-AX-LRA-00-50X-SC - Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring, double insertion slide
103 444 CET1-AX-LDA-00-50X-SC - Read head CES-A-LSP-..., hard-wired encapsulated cable, PVC
104 966 CES-A-LSP-05V-104966104 967 CES-A-LSP-10V-104967106 271 CES-A-LSP-15V-106271106 272 CES-A-LSP-20V-106272104 968 CES-A-LSP-25V-104968 - Read head CES-A-LSP-SB..., plug connector M5
104 969 CES-A-LSP-SB-104969 - Read head CES-A-LNN-...
106 602 CES-A-LNN-05V-106602 - Read head CES-A-LNN-SC...
106 601 CES-A-LNN-SC-106601
 | Manuals |
 | Catalogs |
| Title | Doc. nr. Edition Date | Languages | Document (Downloads) |
|---|
| Berührungsloses Sicherheitssystem CES | 076609 15 09/11 |  | 25865 KB | | Non-Contact Safety System CES | 076649 15 09/11 |  | 25794 KB | | Système de sécurité sans contact CES | 086818 15 09/11 |  | 25835 KB | | Sistema de seguridad sin contacto CES | 086819 15 09/11 |  | 26530 KB | | Sistema di sicurezza senza contatto CES | 076704 08 09/08 |  | 13279 KB |