de-DEen-USfr-FR
Čeština (Česká republika)
Login
HomeSitemapImprint
  • Door monitoring outputs
  • Start button
  • Feedback loop
  • Unicode or multicode evaluation units
  • Guard lock monitoring
Evaluation unit CES-AZ
+more information

CES evaluation units combine transponder evaluation and a safety relay in one device

The CES evaluation units have two enable paths and monitoring outputs for each read head connected. Depending on the series, the devices have additional monitoring outputs as well as connections for a monitored Start button and feedback loop.

Start button

Evaluation units with a connection for a Start button permit a monitored, manual start. The relay is started by actuating a button. The button is monitored for jamming or possible tampering (monitoring of the falling edge). Prior to starting the evaluation unit, the safe state of the safety components connected must be re-established.

Feedback loop

Components connected downstream of the safety relay can be monitored for correct function. For this purpose normally closed contacts on these components are integrated into the feedback loop on the evaluation unit.

Unicode evaluation units

With the unicode version, the actuators must be taught-in on the evaluation unit. During teach-in the actuator code is assigned to the evaluation unit. This code is saved in the evaluation unit. Whenever an actuator is read, the evaluation unit compares the code just read with the code saved. Only if the two bit patterns are identical, the actuator is recognized and the enable paths are closed. The number of possible teach-in operations is dependent of the evaluation unit used. Only the last actuator taught-in is detected. The unicode principle provides a high level of protection against tampering.

Multicode evaluation units

Unlike systems with unique code detection, with multicode evaluation units a specific actuator code is not requested, instead it is only checked whether the actuator is of a type from EUCHNER that can be detected by the system (multicode detection). There is no exact comparison of the actuator code with the code saved in the evaluation unit. As a result a teach-in operation is not necessary.

Guard lock monitoring with the safety system CES-AZ

In principle a read head with guard locking can be connected to each CES evaluation unit with standard read distance. Evaluation units in the system family CES-AZ-… monitor the guard locking function in accordance with EN 1088. For information on which device combination can be used as guard locking in accordance with EN 1088, please refer to the related product page and the combination tables. Evaluation units in the system family CES-A-… do not provide safe guard lock monitoring.

+Evaluation unit CES-AZ-AES-01B/ CES-AZ-UES-01B (for 1 read head)
  • 1 read head can be connected
  • 2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
  • Start button and feedback loop can be connected
  • Plug-in connection terminals
  • Category 4 / PL e according to EN ISO 13849-1
Evaluation unit CES-AZ-AES-01B/ CES-AZ-UES-01B (for 1 read head)

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

New actuators are taught-in by fitting a jumper.

Multicode evaluation

Every suitable actuator is detected by the evaluation unit.

Guard lock monitoring

Evaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories

Category according to EN ISO 13849-1

Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Each safety path is independently safe.

LED indicator

STATEStatus LED
DIADiagnostics LED
OUTSafety output status

Additional connections

TSTInput for self-test
O1Monitoring output (semiconductor)
DIADiagnostics output
Y1, Y2Feedback loop
SStart button connection

Important:The plug-in connection terminals are not included and must be ordered separately.

Order numbers:

Unicode

  • 104 770 CES-AZ-AES-01B

Multicode

  • 105 139 CES-AZ-UES-01B
Evaluation unit CES-AZ-AES-01B/ CES-AZ-UES-01B
Dimension drawing
Block diagram
+Evaluation unit CES-AZ-AES-01B ATEX (for 1 read head)
  • 1 read head can be connected
  • 2 safety contacts (relay contacts) with 2 internally connected NO contacts per output)
  • Plug-in connection terminals
  • Start button and feedback loop can be connected
  • Reset button
  • Category 4 /PL e according to EN 13849-1
Evaluation unit CES-AZ-AES-01B ATEX (for 1 read head)

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

New actuators are taught-in by fitting a jumper.

Guard lock monitoring

Evaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories

Category according to EN 13849-1

Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:

  • Category 4 /PL e according to EN 13849-1

Each safety path is independently safe.

Operating distance

The evaluation unit has the standard operating distance that, e. g., permits larger tolerances in the alignment of read head and actuator.

LED indicator

STATEStatus LED
DIADiagnostics LED
OUTSafety output status

Additional connections

TSTInput for self-test
O1Monitoring output (semiconductor)
DIADiagnostics output
Y1, Y2Feedback loop
SStart button connection (monitoring of the falling edge)

ATEX rating

EX II (3) G [Ex nL] IIC T5

Order numbers:

Unicode

  • 104 770 CES-AZ-AES-01B
  • 105 142 CES-AZ-AES-01B-EX

Multicode

  • 105 139 CES-AZ-UES-01B
  • 106 724 CES-AZ-UES-01B-EX

Connection kits for evaluation unit CES-AZ-.ES-01B

  • 104 756 CES-EA-TC-AK04-104756
  • 112 631 CES-EA-TC-KK04-112631
Evaluation unit CES-AZ-AES-01B
Dimension drawing
Block diagram
+Evaluation unit CES-AZ-AES-02B/ CES-AZ-UES-02B (for 2 read heads)
  • 2 read heads can be connected
  • 2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
  • Start button and feedback loop can be connected
  • Plug-in connection terminals
  • Category 4 / PL e according to EN ISO 13849-1
Evaluation unit CES-AZ-AES-02B/ CES-AZ-UES-02B (for 2 read heads)

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

New actuators are taught-in by fitting a jumper.

Multicode evaluation

Every suitable actuator is detected by the evaluation unit.

Guard lock monitoring

Evaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories

Category according to EN ISO 13849-1

Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Each safety path is independently safe.

LED indicator

STATEStatus LED
DIADiagnostics LED
OUTSafety output status

Additional connections

TSTInput for self-test
O1, O2Monitoring outputs (semiconductor)
DIADiagnostics output
Y1, Y2Feedback loop
SStart button connection (monitoring of the falling edge)

Important:The plug-in connection terminals are not included and must be ordered separately.

Order numbers:

Unicode

  • 104 775 CES-AZ-AES-02B

Multicode

  • 105 140 CES-AZ-UES-02B

Connection kits for evaluation unit CES-AZ-.ES-02B

  • 104 771 CES-EA-TC-AK06-104771
  • 112 630 CES-EA-TC-KK06-112630
Evaluation unit CES-AZ-AES-02B/ CES-AZ-UES-02B
Dimension drawing
Block diagram
+Evaluation unit CES-AZ-AES-04B/ CES-AZ-UES-04B (for 4 read heads)
  • 4 read heads can be connected
  • 2 safety outputs (relay contacts with 2 internally connected NO contacts per output)
  • Start button and feedback loop can be connected
  • Plug-in connection terminals
  • Category 4 / PL e according to EN ISO 13849-1
Evaluation unit CES-AZ-AES-04B/ CES-AZ-UES-04B (for 4 read heads)

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

New actuators are taught-in by fitting a jumper.

Multicode evaluation

Every suitable actuator is detected by the evaluation unit.

Guard lock monitoring

Evaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories

Category according to EN ISO 13849-1

Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Each safety path is independently safe.

LED indicator

STATEStatus LED
DIADiagnostics LED
OUTSafety output status

Additional connections

TSTInput for self-test
O1 ... O4Monitoring outputs (semiconductor)
DIADiagnostics output
Y1, Y2Feedback loop
SStart button connection (monitoring of the falling edge)

Important:The plug-in connection terminals are not included and must be ordered separately.

Order numbers:

Unicode

  • 104 780 CES-AZ-AES-04B

Multicode

  • 105 141 CES-AZ-UES-04B

Connection kits for evaluation unit CES-AZ-.ES-04B

  • 104 776 CES-EA-TC-AK08-104776
  • 112 629 CES-EA-TC-KK08-112629
Evaluation unit CES-AZ-AES-04B/ CES-AZ-UES-04B
Dimension drawing
Block diagram
+Evaluation unit CES-AZ-ABS.../-UBS... (replaced by CES-AZ-AES.../-UES...)
Evaluation unit CES-AZ-ABS.../-UBS... (replaced by CES-AZ-AES.../-UES...)

Important:

Whenever possible, use the following units for new projects:

  • CES-AZ-AES-01B (104 770)
  • CES-AZ-UES-01B (105 139)

Unicode evaluation unit

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Max. 8 actuators can be taught-in.

Only the last actuator taught-in is detected.

Multicode evaluation unit

Every suitable actuator is detected by the evaluation unit.

Guard lock monitoring

Evaluation units in the series CES-AZ make it possible to use read heads with integrated guard locking for the protection of personnel during overtraveling machine movements. You will find suitable read heads in the accessories

Category according to EN ISO 13849-1

Due to two redundant safety paths (relay contacts) with 2 internal, monitored normally open contacts per safety path, suitable for:

  • Category 3 / PL e according to EN ISO 13849-1

Each safety path is independently safe.

Operating distance

The evaluation unit has the standard operating distance that, e.g., permits larger tolerances in the alignment of read head and actuator.

Additional connections

TSTInput for self-test
OUTMonitoring output (semiconductor)
ERRDiagnostics output
GNDConnected internally to 0V (not for high currents)

Important: The plug-in connection terminals are not included and must be ordered separately.

Order numbers:

Unicode

  • 100 064 CES-AZ-ABS-01B

Multicode

  • 100 412 CES-AZ-UBS-01B
Evaluation unit CES-AZ-ABS.../CES-AZ-UBS...
Dimension drawing
Block diagram

Click on the product to view the available accessories!

+Evaluation unit CES-AZ-AES-01B/ CES-AZ-UES-01B (for 1 read head)
Readhead
  • Read head CES-A-LNA...
    071 845 CES-A-LNA-05V
    071 846 CES-A-LNA-10V
    071 847 CES-A-LNA-15V
    071 975 CES-A-LNA-25V
    077 806 CES-A-LNA-05P
    077 807 CES-A-LNA-10P
    084 682 CES-A-LNA-15P
  • Read head CES-A-LNA-SC
    077 715 CES-A-LNA-SC
  • Read head CES-A-LCA...
    088 785 CES-A-LCA-10V
  • Read head CES-A-LQA-SC
    095 650 CES-A-LQA-SC
  • Read head CES-A-LMN-SC
    077 790 CES-A-LMN-SC
  • Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
    094 800 CEM-A-LE05K-S2
  • Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
    095 792 CEM-A-LE05R-S2
  • Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
    095 170 CEM-A-LH10K-S3
  • Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
    095 793 CEM-A-LH10R-S3
  • Read head CET-AX-... with guard locking and guard lock monitoring
    095 735 CET1-AX-LRA-00-50X-SA
    104 062 CET1-AX-LRA-00-50L-SA
  • Read head CET-AX... with guard locking and guard lock monitoring, double insertion slide
    100 399 CET1-AX-LDA-00-50X-SE
  • Read head CET-AX... with guard locking and guard lock monitoring, escape release
    102 161 CET1-AX-LRA-00-50F-SA
  • Read head CET-AX... with guard locking and guard lock monitoring, escape release, double insertion slide
    103 750 CET1-AX-LDA-00-50F-SA
  • Read head CET-AX... with guard locking and guard lock monitoring, 2 plug connectors M8
    102 988 CET1-AX-LRA-00-50X-SC
  • Read head CET-AX... with guard locking and guard lock monitoring, 2 plug connectors M8, double insertion slide
    103 444 CET1-AX-LDA-00-50X-SC
  • Read head CES-A-LSP-...
    104 966 CES-A-LSP-05V-104966
    104 967 CES-A-LSP-10V-104967
    106 271 CES-A-LSP-15V-106271
    106 272 CES-A-LSP-20V-106272
    104 968 CES-A-LSP-25V-104968
  • Read head CES-A-LSP-SB...
    104 969 CES-A-LSP-SB-104969
  • Read head CES-A-LNN-...
    106 602 CES-A-LNN-05V-106602
  • Read head CES-A-LNN-SC...
    106 601 CES-A-LNN-SC-106601
Evaluation Unit
  • Evaluation unit CES-AZ-AES-01B ATEX (for 1 read head)
    104 756 CES-EA-TC-AK04-104756
Connection material
  • Connection set for evaluation unit CES-AZ-.ES-01B
    104 756 CES-EA-TC-AK04-104756
+Evaluation unit CES-AZ-AES-01B ATEX (for 1 read head)
Readhead
  • Read head CES-A-LNA-SC-EX
    098 156 CES-A-LNA-SC-EX
  • Read head CES-A-LMN-SC-EX
    098 157 CES-A-LMN-SC-EX
  • Read head CEM-A-LE05...-EX with guard locking without guard lock monitoring with remanence
    097 174 CEM-A-LE05K-S2-EX
Evaluation Unit
  • Evaluation unit CES-AZ-AES-01B ATEX (for 1 read head)
    104 756 CES-EA-TC-AK04-104756
Connection material
  • Connection set for evaluation unit CES-AZ-.ES-01B
    104 756 CES-EA-TC-AK04-104756
+Evaluation unit CES-AZ-AES-02B/ CES-AZ-UES-02B (for 2 read heads)
Readhead
  • Read head CES-A-LNA...
    071 845 CES-A-LNA-05V
    071 846 CES-A-LNA-10V
    071 847 CES-A-LNA-15V
    071 975 CES-A-LNA-25V
    077 806 CES-A-LNA-05P
    077 807 CES-A-LNA-10P
    084 682 CES-A-LNA-15P
  • Read head CES-A-LNA-SC
    077 715 CES-A-LNA-SC
  • Read head CES-A-LCA...
    088 785 CES-A-LCA-10V
  • Read head CES-A-LQA-SC
    095 650 CES-A-LQA-SC
  • Read head CES-A-LMN-SC
    077 790 CES-A-LMN-SC
  • Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
    094 800 CEM-A-LE05K-S2
  • Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
    095 792 CEM-A-LE05R-S2
  • Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
    095 170 CEM-A-LH10K-S3
  • Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
    095 793 CEM-A-LH10R-S3
  • Read head CET-AX-... with guard locking and guard lock monitoring
    095 735 CET1-AX-LRA-00-50X-SA
    104 062 CET1-AX-LRA-00-50L-SA
  • Read head CET-AX... with guard locking and guard lock monitoring, double insertion slide
    100 399 CET1-AX-LDA-00-50X-SE
  • Read head CET-AX... with guard locking and guard lock monitoring, escape release
    102 161 CET1-AX-LRA-00-50F-SA
  • Read head CET-AX... with guard locking and guard lock monitoring, escape release, double insertion slide
    103 750 CET1-AX-LDA-00-50F-SA
  • Read head CET-AX... with guard locking and guard lock monitoring, 2 plug connectors M8
    102 988 CET1-AX-LRA-00-50X-SC
  • Read head CET-AX... with guard locking and guard lock monitoring, 2 plug connectors M8, double insertion slide
    103 444 CET1-AX-LDA-00-50X-SC
  • Read head CES-A-LSP-...
    104 966 CES-A-LSP-05V-104966
    104 967 CES-A-LSP-10V-104967
    106 271 CES-A-LSP-15V-106271
    106 272 CES-A-LSP-20V-106272
    104 968 CES-A-LSP-25V-104968
  • Read head CES-A-LSP-SB...
    104 969 CES-A-LSP-SB-104969
  • Read head CES-A-LNN-...
    106 602 CES-A-LNN-05V-106602
  • Read head CES-A-LNN-SC...
    106 601 CES-A-LNN-SC-106601
Evaluation Unit
  • Evaluation unit CES-AZ-AES-02B/ CES-AZ-UES-02B (for 2 read heads)
    104 771 CES-EA-TC-AK06-104771
Connection material
  • Connection set for evaluation unit CES-AZ-.ES-02B
    104 771 CES-EA-TC-AK06-104771
+Evaluation unit CES-AZ-AES-04B/ CES-AZ-UES-04B (for 4 read heads)
Readhead
  • Read head CES-A-LNA...
    071 845 CES-A-LNA-05V
    071 846 CES-A-LNA-10V
    071 847 CES-A-LNA-15V
    071 975 CES-A-LNA-25V
    077 806 CES-A-LNA-05P
    077 807 CES-A-LNA-10P
    084 682 CES-A-LNA-15P
  • Read head CES-A-LNA-SC
    077 715 CES-A-LNA-SC
  • Read head CES-A-LCA...
    088 785 CES-A-LCA-10V
  • Read head CES-A-LQA-SC
    095 650 CES-A-LQA-SC
  • Read head CES-A-LMN-SC
    077 790 CES-A-LMN-SC
  • Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
    094 800 CEM-A-LE05K-S2
  • Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
    095 792 CEM-A-LE05R-S2
  • Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
    095 170 CEM-A-LH10K-S3
  • Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
    095 793 CEM-A-LH10R-S3
  • Read head CET-AX-... with guard locking and guard lock monitoring
    095 735 CET1-AX-LRA-00-50X-SA
    104 062 CET1-AX-LRA-00-50L-SA
  • Read head CET-AX... with guard locking and guard lock monitoring, double insertion slide
    100 399 CET1-AX-LDA-00-50X-SE
  • Read head CET-AX... with guard locking and guard lock monitoring, escape release
    102 161 CET1-AX-LRA-00-50F-SA
  • Read head CET-AX... with guard locking and guard lock monitoring, escape release, double insertion slide
    103 750 CET1-AX-LDA-00-50F-SA
  • Read head CET-AX... with guard locking and guard lock monitoring, 2 plug connectors M8
    102 988 CET1-AX-LRA-00-50X-SC
  • Read head CET-AX... with guard locking and guard lock monitoring, 2 plug connectors M8, double insertion slide
    103 444 CET1-AX-LDA-00-50X-SC
  • Read head CES-A-LSP-...
    104 966 CES-A-LSP-05V-104966
    104 967 CES-A-LSP-10V-104967
    106 271 CES-A-LSP-15V-106271
    106 272 CES-A-LSP-20V-106272
    104 968 CES-A-LSP-25V-104968
  • Read head CES-A-LSP-SB...
    104 969 CES-A-LSP-SB-104969
  • Read head CES-A-LNN-...
    106 602 CES-A-LNN-05V-106602
  • Read head CES-A-LNN-SC...
    106 601 CES-A-LNN-SC-106601
Evaluation Unit
  • Evaluation unit CES-AZ-AES-04B/ CES-AZ-UES-04B (for 4 read heads)
    104 776 CES-EA-TC-AK08-104776
Connection material
  • Connection kit for evaluation unit CES-AZ-.ES-04B and CES-AR-AES-12
    104 776 CES-EA-TC-AK08-104776
+Evaluation unit CES-AZ-ABS.../-UBS... (replaced by CES-AZ-AES.../-UES...)
Readhead
  • Read head CES-A-LNA...
    071 845 CES-A-LNA-05V
    071 846 CES-A-LNA-10V
    071 847 CES-A-LNA-15V
    071 975 CES-A-LNA-25V
    077 806 CES-A-LNA-05P
    077 807 CES-A-LNA-10P
    084 682 CES-A-LNA-15P
  • Read head CES-A-LNA-SC
    077 715 CES-A-LNA-SC
  • Read head CES-A-LCA...
    088 785 CES-A-LCA-10V
  • Read head CES-A-LQA-SC
    095 650 CES-A-LQA-SC
  • Read head CES-A-LMN-SC
    077 790 CES-A-LMN-SC
  • Read head CEM-A-LE05... with guard locking without guard lock monitoring with remanence
    094 800 CEM-A-LE05K-S2
  • Read head CEM-A-LE05... with guard locking without guard lock monitoring without remanence
    095 792 CEM-A-LE05R-S2
  • Read head CEM-A-LH10K-S3 with guard locking without guard lock monitoring with remanence
    095 170 CEM-A-LH10K-S3
  • Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence
    095 793 CEM-A-LH10R-S3
  • Read head CET-AX-... with guard locking and guard lock monitoring
    095 735 CET1-AX-LRA-00-50X-SA
    104 062 CET1-AX-LRA-00-50L-SA
  • Read head CET-AX... with guard locking and guard lock monitoring, double insertion slide
    100 399 CET1-AX-LDA-00-50X-SE
  • Read head CET-AX... with guard locking and guard lock monitoring, escape release
    102 161 CET1-AX-LRA-00-50F-SA
  • Read head CET-AX... with guard locking and guard lock monitoring, escape release, double insertion slide
    103 750 CET1-AX-LDA-00-50F-SA
  • Read head CET-AX... with guard locking and guard lock monitoring, 2 plug connectors M8
    102 988 CET1-AX-LRA-00-50X-SC
  • Read head CET-AX... with guard locking and guard lock monitoring, 2 plug connectors M8, double insertion slide
    103 444 CET1-AX-LDA-00-50X-SC
  • Read head CES-A-LSP-...
    104 966 CES-A-LSP-05V-104966
    104 967 CES-A-LSP-10V-104967
    106 271 CES-A-LSP-15V-106271
    106 272 CES-A-LSP-20V-106272
    104 968 CES-A-LSP-25V-104968
  • Read head CES-A-LSP-SB...
    104 969 CES-A-LSP-SB-104969
  • Read head CES-A-LNN-...
    106 602 CES-A-LNN-05V-106602
  • Read head CES-A-LNN-SC...
    106 601 CES-A-LNN-SC-106601
+Manuals and data sheets
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Operating Instructions Safety System CES-A-A.../CES-A-U.../CES-AZ109083
03
06/10
DEENFR
ESIT
PDF 113 KB
System Manual Non-contact safety system CES-AZ-ABS-01B (Unicode)100063
09
08/11
DEPDF 2471 KB
ENPDF 2455 KB
FRPDF 2462 KB
ESPDF 2461 KB
ITPDF 2473 KB
System Manual Non-contact safety system CES-AZ-UBS-01B (Multicode)100414
08
08/11
DEPDF 2069 KB
ENPDF 2054 KB
FRPDF 2061 KB
ESPDF 2059 KB
ITPDF 2070 KB
System Manual Non-contact safety system CES-AZ-AES-... (Unicode)104766
03
12/10
DEPDF 3239 KB
ENPDF 3214 KB
FRPDF 3223 KB
ESPDF 3223 KB
ITPDF 3244 KB
System Manual Non-contact safety system CES-AZ-UES-... (Multicode)105274
03
12/10
DEPDF 3239 KB
ENPDF 3214 KB
FRPDF 3223 KB
ESPDF 3222 KB
ITPDF 3241 KB
System Manual Non-contact safety system CES-AZ-AES-01B-EX (Unicode)105313
03
12/10
DEPDF 1967 KB
ENPDF 1949 KB
System Manual Non-contact safety system CES-AZ-UES-01B-EX (Multicode)106728
02
12/10
DEPDF 1968 KB
ENPDF 1949 KB
+Catalogs
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Evaluation Unit CES-AR-AES – All Safety Doors at a Glance!110640
02
03/11
DEENPDF 122 KB
Berührungsloses Sicherheitssystem CES076609
15
09/11
DEPDF 25865 KB
Non-Contact Safety System CES076649
15
09/11
ENPDF 25794 KB
Système de sécurité sans contact CES086818
15
09/11
FRPDF 25835 KB
Sistema de seguridad sin contacto CES086819
15
09/11
ESPDF 26530 KB
Sistema di sicurezza senza contatto CES076704
08
09/08
ITPDF 13279 KB
+Declarations of conformity
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Title077154
23
PDF 274 KB
+CAD data
Search
+Search Tips:

Product search:

You can also look for parts of article descriptions. Example: NZ*538* or CES-AR*

Document search:

Search directly with the six-digit order number or document number.
Technical Support

Technischer Support

Multifunctional Gate Box

MGB microsite

Interactive presentation of the MGB