Your advantages

  • Safety switch with guard locking and safe guard lock monitoring
  • Integrated CES-AR electronics
    • A special evaluation unit is not required
    • Possible to connect up to 20 devices (CES-AR, CET-AR, MGB-AR,…) in series in an AR chain
  • Safety category 4 and PL e according to EN ISO 13849-1 in case of horizontal mounting, or head downward
  • Two safe semiconductor outputs and monitoring output OUT
  • Safety outputs with pulsing
  • Input (optional) for the connection of feedback loop and start button

Design and functionality

In the CET-AR-… the advantages of the CET-AR-… are combined with the guard locking function of the CET-AX-… The CET-AR-… forms a complete safety solution (PL e according to EN ISO 13849-1). Depending on the version a start button and feedback loop can be connected. As a result the CET-AR-… includes everything that is necessary to secure a safety guard. It could not be easier!

Non-contact safety switch CET-AR
+more information

Connection to safe control systems or safety relays

Do not use a control system or safety relay with pulsing for monitoring short circuits or switch off the pulsing function in these devices. The switch generates its own clock signals on the output lines OA/OB. A downstream device must tolerate these test pulses, which may have a length of up to 1ms.

The inputs on the downstream device must be suitable for positive-switching devices (pnp outputs), as the two outputs on the safety switch deliver a level of +24 V in the switched-on state.

OUT output

The semiconductor output OUT is switched if the safety guard is closed (actuator in the operating distance). It is not allowed to be used for safety functions. The OUT outputs on the individual switches can, however, not be polled if connected in series using a Y-distributor. Evaluation is only possible on parallel wiring to the control cabinet.

RST input

The switches in a chain in a fault state can be reset using the RST input. To do this, a voltage of 24 V is applied to the RST input for at least 3 seconds. It is not necessary to disconnect the supply of power to reset a fault.

Usage as individual switch or switch chain

The safety switch CET-AR can be operated as a compact individual switch or in a switch chain with max. 20 devices.

If a single CET-AR is used, connect the switch as shown in figure above. The OUT output can also be connected here to a control system as a monitoring output.

The switches are connected in series using plug connectors and Y-distributors. The first switch in the chain must always be fitted with a bridging plug. If a safety guard is opened or if a fault occurs on one of the switches, the system shuts down the machine. A higher level control system can, however, not detect which safety guard is open or on which switch a fault has occurred. A special AR evaluation unit is required.

+Non-contact safety switch CET-AR-..., M12, with double insertion slide
  • Read head with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With double insertion slide
  • With 2 plug connectors M12
Non-contact safety switch CET-AR-..., M12, with double insertion slide

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switches

The safety switch CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X.

Important:The actuator must be ordered separately.

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught by connecting the teach-in input to UB (only version with teach-in input).

Multicode evaluation unit

Every suitable actuator is detected by the evaluation unit.

Solenoid operating voltage

  • DC 24 V +10% -15%

Guard locking types

CET1Guard locking by spring force, release by applying voltage to the guard locking solenoid.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 redfreely configurable
LED 2 greenfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important:To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

The category is dependent on the installation position of the safety switch:

Plug connector (view of connection side)

PIN

Designation

Function

Wire color connection cable

2 x M12

S 1.1

IB

Enable input for channel 2

WH

S 1.2

UB

Operating voltage AR electronics, 24 V DC

BN

S 1.3

OA

Safety output, channel 1

GN

S 1.4

OB

Safety output, channel 2

YE

S 1.5

OUT

Door monitoring output

GY

S 1.6

IA

Enable input for channel 1

PK

S 1.7

0 V UB

Operating voltage AR electronics 0 V

BU

S 1.8

RST

Reset input

RD

     

S 2.1

O V UCM

Operating voltage, locking element O V

BN

Depending on version

S 2.2

 

LED 1

LED 1 red, freely configurable 2), 24 V DC

WH

OUT D

 

Door monitoring output (only CET3-AR and CET4-AR)

S 2.3

LED 1

LED 2

LED 1 red or LED 2 green, freely configurable 2), 24 V DC

BU

S 2.4

UCM

Operating voltage guard locking solenoid, 24 V DC

BK

S 2.5

J

Version with teach-in input: To teach-in a new actuator, connect to 24 V DC; in normal operation connect to 0 V.

GY

Y

Version with feedback loop: if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input: This connection must be connected to 0 V.

Order numbers:

Unicode

  • 106 275 CET1-AR-CDA-AH-50X-SG-106275

Multicode

  • 109 231 CET1-AR-CDA-CH-50X-SG-109231
Non-contact safety switch CET-AR...
with 2 plug connectors M12
Dimension drawing
Wiring diagrams
Connection example for separate operation, version with teach-in input
Connection example for separate operation, version without feedback loop and without teach-in input
+Non-contact safety switch CET-AR-..., M12, with escape release
  • Read head with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With escape release
  • With 2 plug connectors M12
Non-contact safety switch CET-AR-..., M12, with escape release

Escape release

Is used for the manual release of the guard locking from within the danger area without tools.

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switches

The safety switch CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X.

Important:The actuator must be ordered separately.

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught by connecting the teach-in input to UB (only version with teach-in input).

Multicode evaluation unit

Every suitable actuator is detected by the evaluation unit.

Solenoid operating voltage

  • DC 24 V +10% -15%

Guard locking types

CET1Guard locking by spring force, release by applying voltage to the guard locking solenoid.
CET2Guard locking by solenoid force, guard locking by applying voltage to the guard locking solenoid. Release by spring force.
CET3Guard locking by spring force with door monitoring output. Function as for CET1-AR, however here the door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator protrudes beyond the extended lift tappet (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 redfreely configurable
LED 2 greenfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important:To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

The category is dependent on the installation position of the safety switch:

Plug connector (view of connection side)

PIN

Designation

Function

Wire color connection cable

2 x M12

S 1.1

IB

Enable input for channel 2

WH

S 1.2

UB

Operating voltage AR electronics, 24 V DC

BN

S 1.3

OA

Safety output, channel 1

GN

S 1.4

OB

Safety output, channel 2

YE

S 1.5

OUT

Door monitoring output

GY

S 1.6

IA

Enable input for channel 1

PK

S 1.7

0 V UB

Operating voltage AR electronics 0 V

BU

S 1.8

RST

Reset input

RD

     

S 2.1

O V UCM

 

BN

Depending on version

S 2.2

 

LED 1

LED 1 red, freely configurable 2), 24 V DC

WH

OUT D

 

Door monitoring output (only CET3-AR and CET4-AR)

S 2.3

LED 1

LED 2

LED 1 red or LED 2 green, freely configurable 2), 24 V DC

BU

S 2.4

UCM

Operating voltage guard locking solenoid, 24 V DC

BK

S 2.5

J

Version with teach-in input: To teach-in a new actuator, connect to 24 V DC; in normal operation connect to 0 V.

GY

Y

Version with feedback loop: if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input: This connection must be connected to 0 V.

Order numbers:

Unicode

  • 106 616 CET1-AR-CRA-AH-50A-SG-106616
  • 106 159 CET1-AR-CRA-AH-50F-SG-106159

Multicode

  • 110 241 CET1-AR-CRA-CH-50F-SG-110241
  • 109 941 CET2-AR-CRA-CH-50F-SG-C2312-109941
  • 110 907 CET3-AR-CRA-CH-50F-SG-110907
Non-contact safety switch CET-AR...
with 2 plug connectors M12
Dimension drawing
Wiring diagrams
Connection example for separate operation, version with teach-in input
Connection example for separate operation, version with start button and feedback loop
Connection example for separate operation, version without feedback loop and without teach-in input
+Non-contact safety switch CET-AR-..., M12, with escape release and lockout bar
  • Read head with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • With escape release
  • With lockout mechanism
Non-contact safety switch CET-AR-..., M12, with escape release and lockout bar

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).

Escape release

Is used for the manual release of the guard locking from within the danger area without tools.

Approach direction

Horizontal

Can be adjusted in 90° steps

Lockout bar

The lockout mechanism can be used to prevent maintenance personnel from being unintentionally locked in the danger area, for example.

Important: The lockout mechanism is not a safety function.

Safety switches

The safety switch CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X.

Important:The actuator must be ordered separately.

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught by connecting the teach-in input to UB (only version with teach-in input).

Multicode evaluation unit

Every suitable actuator is detected by the evaluation unit.

Solenoid operating voltage

  • DC 24 V +10% -15%

Guard locking types

CET1Guard locking by spring force, release by applying voltage to the guard locking solenoid.
CET3Guard locking by spring force with door monitoring output. Function as for CET1-AR, however here the door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator protrudes beyond the extended lift tappet (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 redfreely configurable
LED 2 greenfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important:To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

The category is dependent on the installation position of the safety switch:

Plug connector (view of connection side)

PIN

Designation

Function

Wire color connection cable

2 x M12

S 1.1

IB

Enable input for channel 2

WH

S 1.2

UB

Operating voltage AR electronics, 24 V DC

BN

S 1.3

OA

Safety output, channel 1

GN

S 1.4

OB

Safety output, channel 2

YE

S 1.5

OUT

Door monitoring output

GY

S 1.6

IA

Enable input for channel 1

PK

S 1.7

0 V UB

Operating voltage AR electronics 0 V

BU

S 1.8

RST

Reset input

RD

     

S 2.1

O V UCM

 

BN

Depending on version

S 2.2

 

LED 1

LED 1 red, freely configurable 2), 24 V DC

WH

OUT D

 

Door monitoring output (only CET3-AR and CET4-AR)

S 2.3

LED 1

LED 2

LED 1 red or LED 2 green, freely configurable 2), 24 V DC

BU

S 2.4

UCM

Operating voltage guard locking solenoid, 24 V DC

BK

S 2.5

J

Version with teach-in input: To teach-in a new actuator, connect to 24 V DC; in normal operation connect to 0 V.

GY

Y

Version with feedback loop: if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input: This connection must be connected to 0 V.

Order numbers:

Unicode

  • 111 766 CET1-AR-CRA-AH-50F-SG-C2333-111766

Multicode

  • 112 921 CET3-AR-CRA-CH-50F-SG-C2333-112921
Non-contact safety switch CET-AR...
with 2 plug connectors M12
Dimension drawing
Wiring diagrams
Connection example for separate operation, version with teach-in input
Connection example for separate operation, version with start button and feedback loop
Connection example for separate operation, version without feedback loop and without teach-in input
+Non-contact safety switch CET-AR-..., M12
  • Read head with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
Non-contact safety switch CET-AR-..., M12

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switches

The safety switch CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X.

Important:The actuator must be ordered separately.

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught by connecting the teach-in input to UB (only version with teach-in input).

Multicode evaluation unit

Every suitable actuator is detected by the evaluation unit.

Solenoid operating voltage

  • DC 24 V +10% -15%

Guard locking types

CET1Guard locking by spring force, release by applying voltage to the guard locking solenoid.
CET2Guard locking by solenoid force, guard locking by applying voltage to the guard locking solenoid. Release by spring force.
CET3Guard locking by spring force with door monitoring output. Function as for CET1-AR, however here the door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator protrudes beyond the extended lift tappet (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 redfreely configurable
LED 2 greenfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important:To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

The category is dependent on the installation position of the safety switch:

Plug connector (view of connection side)

PIN

Designation

Function

Wire color connection cable

2 x M12

S 1.1

IB

Enable input for channel 2

WH

S 1.2

UB

Operating voltage AR electronics, 24 V DC

BN

S 1.3

OA

Safety output, channel 1

GN

S 1.4

OB

Safety output, channel 2

YE

S 1.5

OUT

Door monitoring output

GY

S 1.6

IA

Enable input for channel 1

PK

S 1.7

0 V UB

Operating voltage AR electronics 0 V

BU

S 1.8

RST

Reset input

RD

     

S 2.1

O V UCM

Operating voltage, locking element O V

BN

Depending on version

S 2.2

 

LED 1

LED 1 red, freely configurable 2), 24 V DC

WH

OUT D

 

Door monitoring output (only CET3-AR and CET4-AR)

S 2.3

LED 1

LED 2

LED 1 red or LED 2 green, freely configurable 2), 24 V DC

BU

S 2.4

UCM

Operating voltage guard locking solenoid, 24 V DC

BK

S 2.5

J

Version with teach-in input: To teach-in a new actuator, connect to 24 V DC; in normal operation connect to 0 V.

GY

Y

Version with feedback loop: if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input: This connection must be connected to 0 V.

Order numbers:

Unicode

  • 105 802 CET1-AR-CRA-AH-50S-SG-105802
  • 103 418 CET1-AR-CRA-AH-50X-SG-103418
  • 109 075 CET2-AR-CRA-AH-50S-SG-109075
  • 110 240 CET2-AR-CRA-AH-50X-SG-110240
  • 109 401 CET3-AR-CRA-AH-50X-SG-109401

Multicode

  • 105 764 CET1-AR-CRA-CH-50S-SG-105764
  • 105 763 CET1-AR-CRA-CH-50X-SG-105763
  • 110 082 CET2-AR-CRA-CH-50X-SG-110082
  • 110 906 CET3-AR-CRA-CH-50X-SG-110906
  • 112 992 CET3-AR-CRA-CH-50S-SG-112992
Non-contact safety switch CET-AR...
with 2 plug connectors M12
Dimension drawing
Wiring diagrams
Connection example for separate operation, version with teach-in input
Connection example for separate operation, version with start button and feedback loop
Connection example for separate operation, version without feedback loop and without teach-in input
+Non-contact safety switch CET-AR-..., M12, with lockout bar
  • Read head with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • With lockout mechanism
Non-contact safety switch CET-AR-..., M12, with lockout bar

Mechanical Release

Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).

Lockout bar

The lockout mechanism can be used to prevent maintenance personnel from being unintentionally locked in the danger area, for example.

Important: The lockout mechanism is not a safety function.

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switches

The safety switch CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X.

Important:The actuator must be ordered separately.

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught by connecting the teach-in input to UB (only version with teach-in input).

Solenoid operating voltage

  • DC 24 V +10% -15%

Guard locking types

CET1Guard locking by spring force, release by applying voltage to the guard locking solenoid.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 redfreely configurable
LED 2 greenfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important:To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

The category is dependent on the installation position of the safety switch:

Plug connector (view of connection side)

PIN

Designation

Function

Wire color connection cable

2 x M12

S 1.1

IB

Enable input for channel 2

WH

S 1.2

UB

Operating voltage AR electronics, 24 V DC

BN

S 1.3

OA

Safety output, channel 1

GN

S 1.4

OB

Safety output, channel 2

YE

S 1.5

OUT

Door monitoring output

GY

S 1.6

IA

Enable input for channel 1

PK

S 1.7

0 V UB

Operating voltage AR electronics 0 V

BU

S 1.8

RST

Reset input

RD

     

S 2.1

O V UCM

 

BN

Depending on version

S 2.2

 

LED 1

LED 1 red, freely configurable 2), 24 V DC

WH

OUT D

 

Door monitoring output (only CET3-AR and CET4-AR)

S 2.3

LED 1

LED 2

LED 1 red or LED 2 green, freely configurable 2), 24 V DC

BU

S 2.4

UCM

Operating voltage guard locking solenoid, 24 V DC

BK

S 2.5

J

Version with teach-in input: To teach-in a new actuator, connect to 24 V DC; in normal operation connect to 0 V.

GY

Y

Version with feedback loop: if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input: This connection must be connected to 0 V.

Order numbers:

Unicode

  • 112 121 CET1-AR-CRA-AH-50X-SG-C2333-112121
Non-contact safety switch CET-AR...
with 2 plug connectors M12
Dimension drawing
Wiring diagrams
Connection example for separate operation, version with teach-in input
Connection example for separate operation, version with start button and feedback loop
Connection example for separate operation, version without feedback loop and without teach-in input
+Non-contact safety switch CET-AR-..., M12, with Bowden wire
  • Read head with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • With front wire release
Non-contact safety switch CET-AR-..., M12, with Bowden wire

Front wire release (bowden)

The wire front release permits remote release of the guard locking via a pull rope. Flexible routing of the pull rope permits release of the guard locking in inaccessible installation situations.

Important: The wire front release is not a safety function.

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switches

The safety switch CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X.

Important:The actuator must be ordered separately.

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught by connecting the teach-in input to UB (only version with teach-in input).

Multicode evaluation unit

Every suitable actuator is detected by the evaluation unit.

Solenoid operating voltage

  • DC 24 V +10% -15%

Guard locking types

CET1Guard locking by spring force, release by applying voltage to the guard locking solenoid.
CET3Guard locking by spring force with door monitoring output. Function as for CET1-AR, however here the door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator protrudes beyond the extended lift tappet (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 redfreely configurable
LED 2 greenfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important:To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

The category is dependent on the installation position of the safety switch:

Plug connector (view of connection side)

PIN

Designation

Function

Wire color connection cable

2 x M12

S 1.1

IB

Enable input for channel 2

WH

S 1.2

UB

Operating voltage AR electronics, 24 V DC

BN

S 1.3

OA

Safety output, channel 1

GN

S 1.4

OB

Safety output, channel 2

YE

S 1.5

OUT

Door monitoring output

GY

S 1.6

IA

Enable input for channel 1

PK

S 1.7

0 V UB

Operating voltage AR electronics 0 V

BU

S 1.8

RST

Reset input

RD

     

S 2.1

O V UCM

 

BN

Depending on version

S 2.2

 

LED 1

LED 1 red, freely configurable 2), 24 V DC

WH

OUT D

 

Door monitoring output (only CET3-AR and CET4-AR)

S 2.3

LED 1

LED 2

LED 1 red or LED 2 green, freely configurable 2), 24 V DC

BU

S 2.4

UCM

Operating voltage guard locking solenoid, 24 V DC

BK

S 2.5

J

Version with teach-in input: To teach-in a new actuator, connect to 24 V DC; in normal operation connect to 0 V.

GY

Y

Version with feedback loop: if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input: This connection must be connected to 0 V.

Order numbers:

Unicode

  • 113 139 CET3-AR-CRA-AH-50X-SG-C2290-113139

Multicode

  • 109 015 CET1-AR-CRA-CH-50X-SG-C2290-109015
  • 110 114 CET3-AR-CRA-CH-50X-SG-C2290-110114
Non-contact safety switch CET-AR...
with 2 plug connectors M12
Dimension drawing
Wiring diagrams
Connection example for separate operation, version with teach-in input
Connection example for separate operation, version without feedback loop and without teach-in input
+Non-contact safety switch CET-AR-..., M12, with Bowden wire and escape release
  • Read head with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • With front wire release
  • With escape release
Non-contact safety switch CET-AR-..., M12, with Bowden wire and escape release

Front wire release (bowden)

The wire front release permits remote release of the guard locking via a pull rope. Flexible routing of the pull rope permits release of the guard locking in inaccessible installation situations.

Important: The wire front release is not a safety function.

Escape release

Is used for the manual release of the guard locking from within the danger area without tools.

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switches

The safety switch CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X.

Important:The actuator must be ordered separately.

Multicode evaluation unit

Every suitable actuator is detected by the evaluation unit.

Solenoid operating voltage

  • DC 24 V +10% -15%

Guard locking type

CET3Guard locking by spring force with door monitoring output. Function as for CET1-AR, however here the door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator protrudes beyond the extended lift tappet (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 redfreely configurable
LED 2 greenfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important:To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

The category is dependent on the installation position of the safety switch:

Plug connector (view of connection side)

PIN

Designation

Function

Wire color connection cable

2 x M12

S 1.1

IB

Enable input for channel 2

WH

S 1.2

UB

Operating voltage AR electronics, 24 V DC

BN

S 1.3

OA

Safety output, channel 1

GN

S 1.4

OB

Safety output, channel 2

YE

S 1.5

OUT

Door monitoring output

GY

S 1.6

IA

Enable input for channel 1

PK

S 1.7

0 V UB

Operating voltage AR electronics 0 V

BU

S 1.8

RST

Reset input

RD

     

S 2.1

O V UCM

 

BN

Depending on version

S 2.2

 

LED 1

LED 1 red, freely configurable 2), 24 V DC

WH

OUT D

 

Door monitoring output (only CET3-AR and CET4-AR)

S 2.3

LED 1

LED 2

LED 1 red or LED 2 green, freely configurable 2), 24 V DC

BU

S 2.4

UCM

Operating voltage guard locking solenoid, 24 V DC

BK

S 2.5

J

Version with teach-in input: To teach-in a new actuator, connect to 24 V DC; in normal operation connect to 0 V.

GY

Y

Version with feedback loop: if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input: This connection must be connected to 0 V.

Order numbers:

Multicode

  • 110 905 CET3-AR-CRA-CH-50F-SG-C2290-110905
Non-contact safety switch CET3-AR...
with 2 plug connectors M12
Dimension drawing
Wiring diagrams
Connection example for separate operation, version without feedback loop and without teach-in input
+Non-contact safety switch CET-AR-..., RC18
  • Read head with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With plug connector RC18
Non-contact safety switch CET-AR-..., RC18

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switches

The safety switch CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X.

Important:The actuator must be ordered separately.

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught by connecting the teach-in input to UB (only version with teach-in input).

Multicode evaluation unit

Every suitable actuator is detected by the evaluation unit.

Solenoid operating voltage

  • DC 24 V +10% -15%

Guard locking types

CET1Guard locking by spring force, release by applying voltage to the guard locking solenoid.
CET2Guard locking by solenoid force, guard locking by applying voltage to the guard locking solenoid. Release by spring force.
CET3Guard locking by spring force with door monitoring output. Function as for CET1-AR, however here the door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator protrudes beyond the extended lift tappet (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 redfreely configurable
LED 2 greenfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important:To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

The category is dependent on the installation position of the safety switch:

Plug connector (view of connection side)

PIN

Designation

Function

RC18

1

UCM

Operating voltage guard locking solenoid, DC 24 V

2

IA

Enable input for channel 1

3

IB

Enable input for channel 2

4

OA

Safety output, channel 1

5

OB

Safety output, channel 2

6

UB

Operating voltage AR electronics, DC 24 V

7

RST

Reset input

8

OUT D

Door monitoring output (only CET3-AR and CET4-AR)

 

9

-

n.c.

10

OUT

Door monitoring output

Depending on version

11

-

n.c.

12

FE

Function earth

13

J

Version with teach-in input: To teach-in a new actuator, connect to 24 V DC; in normal operation connect to 0 V.

Y

Version with feedback loop: if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input: This connection must be connected to 0 V.

14

-

n.c.

15

LED 1

LED 1 red, freely configurable, 24 V DC

16

LED 2

LED 2 green, freely configurable, 24 V DC

17

-

n.c.

18

0V UCM

Operating voltage guard locking solenoid 0 V

19

0V UB

Operating voltage AR electronics 0 V

Order numbers:

Unicode

  • 110 203 CET1-AR-CRA-AH-50X-SH-110203
  • 110 205 CET2-AR-CRA-AH-50X-SH-110205
  • 110 103 CET3-AR-CRA-AH-50X-SH-110103

Multicode

  • 110 204 CET1-AR-CRA-CH-50X-SH-110204
  • 110 206 CET2-AR-CRA-CH-50X-SH-110206
  • 110 104 CET3-AR-CRA-CH-50X-SH-110104
Non-contact safety switch CET-AR...
with plug connector RC18
Dimension drawing
Wiring diagrams
Connection example for separate operation, version with teach-in input
Connection example for separate operation, version without feedback loop and without teach-in input
+Non-contact safety switch CET-AR-..., RC18, with Bowden wire
  • Read head with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • Plug connector RC18
  • With front wire release
Non-contact safety switch CET-AR-..., RC18, with Bowden wire

Front wire release (bowden)

The wire front release permits remote release of the guard locking via a pull rope. Flexible routing of the pull rope permits release of the guard locking in inaccessible installation situations.

Important: The wire front release is not a safety function.

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switches

The safety switch CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X.

Important:The actuator must be ordered separately.

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught by connecting the teach-in input to UB (only version with teach-in input).

Solenoid operating voltage

  • DC 24 V +10% -15%

Guard locking types

CET1Guard locking by spring force, release by applying voltage to the guard locking solenoid.
CET3Guard locking by spring force with door monitoring output. Function as for CET1-AR, however here the door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator protrudes beyond the extended lift tappet (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 redfreely configurable
LED 2 greenfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important:To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

The category is dependent on the installation position of the safety switch:

Plug connector (view of connection side)

PIN

Designation

Function

RC18

1

UCM

Operating voltage guard locking solenoid, DC 24 V

2

IA

Enable input for channel 1

3

IB

Enable input for channel 2

4

OA

Safety output, channel 1

5

OB

Safety output, channel 2

6

UB

Operating voltage AR electronics, DC 24 V

7

RST

Reset input

8

OUT D

Door monitoring output (only CET3-AR and CET4-AR)

 

9

-

n.c.

10

OUT

Door monitoring output

Depending on version

11

-

n.c.

12

FE

Function earth

13

J

Version with teach-in input: To teach-in a new actuator, connect to 24 V DC; in normal operation connect to 0 V.

Y

Version with feedback loop: if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input: This connection must be connected to 0 V.

14

-

n.c.

15

LED 1

LED 1 red, freely configurable, 24 V DC

16

LED 2

LED 2 green, freely configurable, 24 V DC

17

-

n.c.

18

0V UCM

Operating voltage guard locking solenoid 0 V

19

0V UB

Operating voltage AR electronics 0 V

Order numbers:

Unicode

  • 113 022 CET1-AR-CRA-AH-50X-SH-C2290-113022
  • 113 024 CET3-AR-CRA-AH-50X-SH-C2290-113024
Non-contact safety switch CET-AR...
with plug connector RC18
Dimension drawing
Wiring diagrams
Connection example for separate operation, version with teach-in input
Connection example for separate operation, version without feedback loop and without teach-in input
+Non-contact safety switch CET-AR-..., RC18, with escape release
  • Read head with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With plug connector RC18
  • With escape release
Non-contact safety switch CET-AR-..., RC18, with escape release

Escape release

Is used for the manual release of the guard locking from within the danger area without tools.

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switches

The safety switch CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X.

Important:The actuator must be ordered separately.

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught by connecting the teach-in input to UB (only version with teach-in input).

Solenoid operating voltage

  • DC 24 V +10% -15%

Guard locking types

CET1Guard locking by spring force, release by applying voltage to the guard locking solenoid.
CET3Guard locking by spring force with door monitoring output. Function as for CET1-AR, however here the door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator protrudes beyond the extended lift tappet (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 redfreely configurable
LED 2 greenfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important:To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

The category is dependent on the installation position of the safety switch:

Plug connector (view of connection side)

PIN

Designation

Function

RC18

1

UCM

Operating voltage guard locking solenoid, DC 24 V

2

IA

Enable input for channel 1

3

IB

Enable input for channel 2

4

OA

Safety output, channel 1

5

OB

Safety output, channel 2

6

UB

Operating voltage AR electronics, DC 24 V

7

RST

Reset input

8

OUT D

Door monitoring output (only CET3-AR and CET4-AR)

 

9

-

n.c.

10

OUT

Door monitoring output

Depending on version

11

-

n.c.

12

FE

Function earth

13

J

Version with teach-in input: To teach-in a new actuator, connect to 24 V DC; in normal operation connect to 0 V.

Y

Version with feedback loop: if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input: This connection must be connected to 0 V.

14

-

n.c.

15

LED 1

LED 1 red, freely configurable, 24 V DC

16

LED 2

LED 2 green, freely configurable, 24 V DC

17

-

n.c.

18

0V UCM

Operating voltage guard locking solenoid 0 V

19

0V UB

Operating voltage AR electronics 0 V

Order numbers:

Unicode

  • 110 943 CET1-AR-CRA-AH-50F-SH-C2312-110943
  • 111 725 CET3-AR-CRA-AH-50X-SH-111725
  • 113 148 CET3-AR-CRA-AH-50F-SH-113148
Non-contact safety switch CET-AR...
with plug connector RC18
Dimension drawing
Wiring diagrams
Connection example for separate operation, version with teach-in input
+Non-contact safety switch CET-AR-..., RC18, with Bowden wire and escape release
  • Read head with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • Plug connector RC18
  • With front wire release
  • With escape release
Non-contact safety switch CET-AR-..., RC18, with Bowden wire and escape release

Front wire release (bowden)

The wire front release permits remote release of the guard locking via a pull rope. Flexible routing of the pull rope permits release of the guard locking in inaccessible installation situations.

Important: The wire front release is not a safety function.

Escape release

Is used for the manual release of the guard locking from within the danger area without tools.

Approach direction

Horizontal

Can be adjusted in 90° steps

Safety switches

The safety switch CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X.

Important:The actuator must be ordered separately.

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught by connecting the teach-in input to UB (only version with teach-in input).

Solenoid operating voltage

  • DC 24 V +10% -15%

Guard locking types

CET1Guard locking by spring force, release by applying voltage to the guard locking solenoid.
CET3Guard locking by spring force with door monitoring output. Function as for CET1-AR, however here the door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator protrudes beyond the extended lift tappet (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 redfreely configurable
LED 2 greenfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important:To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

The category is dependent on the installation position of the safety switch:

Plug connector (view of connection side)

PIN

Designation

Function

RC18

1

UCM

Operating voltage guard locking solenoid, DC 24 V

2

IA

Enable input for channel 1

3

IB

Enable input for channel 2

4

OA

Safety output, channel 1

5

OB

Safety output, channel 2

6

UB

Operating voltage AR electronics, DC 24 V

7

RST

Reset input

8

OUT D

Door monitoring output (only CET3-AR and CET4-AR)

 

9

-

n.c.

10

OUT

Door monitoring output

Depending on version

11

-

n.c.

12

FE

Function earth

13

J

Version with teach-in input: To teach-in a new actuator, connect to 24 V DC; in normal operation connect to 0 V.

Y

Version with feedback loop: if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input: This connection must be connected to 0 V.

14

-

n.c.

15

LED 1

LED 1 red, freely configurable, 24 V DC

16

LED 2

LED 2 green, freely configurable, 24 V DC

17

-

n.c.

18

0V UCM

Operating voltage guard locking solenoid 0 V

19

0V UB

Operating voltage AR electronics 0 V

Order numbers:

Unicode

  • 113 021 CET1-AR-CRA-AH-50F-SH-C2312-110943
  • 113 023 CET3-AR-CRA-AH-50F-SH-C2353-113023
Non-contact safety switch CET-AR...
with plug connector RC18
Dimension drawing
Wiring diagrams
Connection example for separate operation, version with teach-in input
+Non-contact safety switch CET-AR-..., RC18, with lockout bar
  • Read head with guard locking and integrated evaluation electronics
  • Locking force up to 6500 N
  • Up to 20 switches in series
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • Plug connector RC18
  • With lockout mechanism
Non-contact safety switch CET-AR-..., RC18, with lockout bar

Approach direction

Horizontal

Can be adjusted in 90° steps

Lockout bar

The lockout mechanism can be used to prevent maintenance personnel from being unintentionally locked in the danger area, for example.

Important: The lockout mechanism is not a safety function.

Safety switches

The safety switch CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X.

Important:The actuator must be ordered separately.

Unicode evaluation

Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught by connecting the teach-in input to UB (only version with teach-in input).

Solenoid operating voltage

  • DC 24 V +10% -15%

Guard locking types

CET3Guard locking by spring force with door monitoring output. Function as for CET1-AR, however here the door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator protrudes beyond the extended lift tappet (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active.

LED function display

State LEDStatus LED
DIA LEDDiagnostics LED
LED 1 redfreely configurable
LED 2 greenfreely configurable

Additional connections

OUTMonitoring output (semiconductor)
RSTReset input

Category according to EN ISO 13849-1

Due to two redundant design semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN ISO 13849-1

Important:To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

The category is dependent on the installation position of the safety switch:

Plug connector (view of connection side)

PIN

Designation

Function

RC18

1

UCM

Operating voltage guard locking solenoid, DC 24 V

2

IA

Enable input for channel 1

3

IB

Enable input for channel 2

4

OA

Safety output, channel 1

5

OB

Safety output, channel 2

6

UB

Operating voltage AR electronics, DC 24 V

7

RST

Reset input

8

OUT D

Door monitoring output (only CET3-AR and CET4-AR)

 

9

-

n.c.

10

OUT

Door monitoring output

Depending on version

11

-

n.c.

12

FE

Function earth

13

J

Version with teach-in input: To teach-in a new actuator, connect to 24 V DC; in normal operation connect to 0 V.

Y

Version with feedback loop: if the feedback loop is not used, connect to 24 V DC

-

Version without feedback loop and without teach-in input: This connection must be connected to 0 V.

14

-

n.c.

15

LED 1

LED 1 red, freely configurable, 24 V DC

16

LED 2

LED 2 green, freely configurable, 24 V DC

17

-

n.c.

18

0V UCM

Operating voltage guard locking solenoid 0 V

19

0V UB

Operating voltage AR electronics 0 V

Order numbers:

Unicode

  • 113 151 CET3-AR-CRA-AH-50X-SH-C2333-113151
Non-contact safety switch CET-AR...
with plug connector RC18
Dimension drawing
Wiring diagrams
Connection example for separate operation, version with teach-in input

Click on the product to view the available accessories!

+Non-contact safety switch CET-AR-..., M12, with double insertion slide
Actuator
  • Actuator CET-A-BWK-50X
    096 327 CET-A-BWK-50X
Bolt
  • Bolt CET-A-C
    104 309 Bolt CET-A-C
  • Bolt CET-A-C/F with escape release
    106 172 Bolt CET-A-C/F
Fastening
  • Mounting plate EMP-L-... for safety switches CET
    106 695 EMP-L-CET
  • Mounting plate EMP-B-... for actuator CET
    106 694 EMP-B-CET
  • Safety screws M5 x 16 for actuator CET-A-BWK-50X
    073 456 M5x16/V100
  • Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...
    074 063 M4x14/V100
Add-On
  • Mechanical key release for read head CET
    098 850 Schlüsselhilfsentriegelung
    099 434 Ersatzschlüssel
  • Emergency unlocking for read head CET
    103 714 Emergency unlocking CET
  • Cover for read head and actuator CET
    098 808 CET Abdeckung rechts
    098 807 CET Abdeckung links
  • Wire front release (bowden) for non-contact safety switches CET-AR
    109 352 BW-CET-C-3000-F-109352
  • Handle for wire front release (Bowden)
    099 795 BW-Griff
  • Lock for emergency unlocking with manual return for safety switches TP/STP
    099 434 Ersatzschlüssel TP gleichschließend
Connection material
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-AR/CES-AP-C01
    100 177 C-M12F08-08X025PV05,0-ZN-100177
    100 178 C-M12F08-08X025PV10,0-ZN-100178
    100 179 C-M12F08-08X025PV20,0-ZN-100179
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-ART/CES-AP
    100 183 C-M12F05-05X034PV05,0-ZN-100183
    100 184 C-M12F05-05X034PV10,0-ZN-100184
    100 185 C-M12F05-05X034PV20,0-ZN-100185
  • Connection cables with 2 plug connectors M12 for safety switch CES-AR/CET-AR
    100 180 C-M12F05-05X034PV05,0-M12M05-100180
    100 181 C-M12F05-05X034PV10,0-M12M05-100181
    100 182 C-M12F05-05X034PV20,0-M12M05-100182
  • Bridging plug M12
    097 645 Bridging plug
  • Y-distributor M12
    097 627 Y-distributor M12
  • Connection cables with female plug M8 and flying lead for CES-AR-C.2
    106 671 C-M08F08-08X014PU05,0-ES-106671
    106 672 C-M08F08-08X014PU10,0-ES-106672
    106 673 C-M08F08-08X014PU20,0-ES-106673
    110 933 C-M08F08-08X014PV205,0-ES-110933
    110 934 C-M08F08-08X014PV210,0-ES-110934
    110 935 C-M08F08-08X014PV210,0-ES-110935
    111 603 C-M08F08-08X014PV220,0-ES-111603
  • Y-distributor M12 with connection cable
    111 696 Y-Verteiler M12 mit Anschlussleitung
+Non-contact safety switch CET-AR-..., M12, with escape release
Actuator
  • Actuator CET-A-BWK-50X
    096 327 CET-A-BWK-50X
Bolt
  • Bolt CET-A-C
    104 309 Bolt CET-A-C
  • Bolt CET-A-C/F with escape release
    106 172 Bolt CET-A-C/F
Fastening
  • Mounting plate EMP-L-... for safety switches CET
    106 695 EMP-L-CET
  • Mounting plate EMP-B-... for actuator CET
    106 694 EMP-B-CET
  • Safety screws M5 x 16 for actuator CET-A-BWK-50X
    073 456 M5x16/V100
  • Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...
    074 063 M4x14/V100
Add-On
  • Mechanical key release for read head CET
    098 850 Schlüsselhilfsentriegelung
    099 434 Ersatzschlüssel
  • Emergency unlocking for read head CET
    103 714 Emergency unlocking CET
  • Cover for read head and actuator CET
    098 808 CET Abdeckung rechts
    098 807 CET Abdeckung links
  • Wire front release (bowden) for non-contact safety switches CET-AR
    109 352 BW-CET-C-3000-F-109352
  • Handle for wire front release (Bowden)
    099 795 BW-Griff
  • Lock for emergency unlocking with manual return for safety switches TP/STP
    099 434 Ersatzschlüssel TP gleichschließend
Connection material
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-AR/CES-AP-C01
    100 177 C-M12F08-08X025PV05,0-ZN-100177
    100 178 C-M12F08-08X025PV10,0-ZN-100178
    100 179 C-M12F08-08X025PV20,0-ZN-100179
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-ART/CES-AP
    100 183 C-M12F05-05X034PV05,0-ZN-100183
    100 184 C-M12F05-05X034PV10,0-ZN-100184
    100 185 C-M12F05-05X034PV20,0-ZN-100185
  • Connection cables with 2 plug connectors M12 for safety switch CES-AR/CET-AR
    100 180 C-M12F05-05X034PV05,0-M12M05-100180
    100 181 C-M12F05-05X034PV10,0-M12M05-100181
    100 182 C-M12F05-05X034PV20,0-M12M05-100182
  • Bridging plug M12
    097 645 Bridging plug
  • Y-distributor M12
    097 627 Y-distributor M12
  • Connection cables with female plug M8 and flying lead for CES-AR-C.2
    106 671 C-M08F08-08X014PU05,0-ES-106671
    106 672 C-M08F08-08X014PU10,0-ES-106672
    106 673 C-M08F08-08X014PU20,0-ES-106673
    110 933 C-M08F08-08X014PV205,0-ES-110933
    110 934 C-M08F08-08X014PV210,0-ES-110934
    110 935 C-M08F08-08X014PV210,0-ES-110935
    111 603 C-M08F08-08X014PV220,0-ES-111603
  • Y-distributor M12 with connection cable
    111 696 Y-Verteiler M12 mit Anschlussleitung
+Non-contact safety switch CET-AR-..., M12, with escape release and lockout bar
Actuator
  • Actuator CET-A-BWK-50X
    096 327 CET-A-BWK-50X
Bolt
  • Bolt CET-A-C
    104 309 Bolt CET-A-C
  • Bolt CET-A-C/F with escape release
    106 172 Bolt CET-A-C/F
Fastening
  • Mounting plate EMP-L-... for safety switches CET
    106 695 EMP-L-CET
  • Mounting plate EMP-B-... for actuator CET
    106 694 EMP-B-CET
  • Safety screws M5 x 16 for actuator CET-A-BWK-50X
    073 456 M5x16/V100
  • Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...
    074 063 M4x14/V100
Add-On
  • Mechanical key release for read head CET
    098 850 Schlüsselhilfsentriegelung
    099 434 Ersatzschlüssel
  • Emergency unlocking for read head CET
    103 714 Emergency unlocking CET
  • Cover for read head and actuator CET
    098 808 CET Abdeckung rechts
    098 807 CET Abdeckung links
  • Wire front release (bowden) for non-contact safety switches CET-AR
    109 352 BW-CET-C-3000-F-109352
  • Handle for wire front release (Bowden)
    099 795 BW-Griff
  • Lock for emergency unlocking with manual return for safety switches TP/STP
    099 434 Ersatzschlüssel TP gleichschließend
Connection material
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-AR/CES-AP-C01
    100 177 C-M12F08-08X025PV05,0-ZN-100177
    100 178 C-M12F08-08X025PV10,0-ZN-100178
    100 179 C-M12F08-08X025PV20,0-ZN-100179
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-ART/CES-AP
    100 183 C-M12F05-05X034PV05,0-ZN-100183
    100 184 C-M12F05-05X034PV10,0-ZN-100184
    100 185 C-M12F05-05X034PV20,0-ZN-100185
  • Connection cables with 2 plug connectors M12 for safety switch CES-AR/CET-AR
    100 180 C-M12F05-05X034PV05,0-M12M05-100180
    100 181 C-M12F05-05X034PV10,0-M12M05-100181
    100 182 C-M12F05-05X034PV20,0-M12M05-100182
  • Bridging plug M12
    097 645 Bridging plug
  • Y-distributor M12
    097 627 Y-distributor M12
  • Connection cables with female plug M8 and flying lead for CES-AR-C.2
    106 671 C-M08F08-08X014PU05,0-ES-106671
    106 672 C-M08F08-08X014PU10,0-ES-106672
    106 673 C-M08F08-08X014PU20,0-ES-106673
    110 933 C-M08F08-08X014PV205,0-ES-110933
    110 934 C-M08F08-08X014PV210,0-ES-110934
    110 935 C-M08F08-08X014PV210,0-ES-110935
    111 603 C-M08F08-08X014PV220,0-ES-111603
  • Y-distributor M12 with connection cable
    111 696 Y-Verteiler M12 mit Anschlussleitung
+Non-contact safety switch CET-AR-..., M12
Actuator
  • Actuator CET-A-BWK-50X
    096 327 CET-A-BWK-50X
Bolt
  • Bolt CET-A-C
    104 309 Bolt CET-A-C
  • Bolt CET-A-C/F with escape release
    106 172 Bolt CET-A-C/F
Fastening
  • Mounting plate EMP-L-... for safety switches CET
    106 695 EMP-L-CET
  • Mounting plate EMP-B-... for actuator CET
    106 694 EMP-B-CET
  • Safety screws M5 x 16 for actuator CET-A-BWK-50X
    073 456 M5x16/V100
  • Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...
    074 063 M4x14/V100
Add-On
  • Mechanical key release for read head CET
    098 850 Schlüsselhilfsentriegelung
    099 434 Ersatzschlüssel
  • Emergency unlocking for read head CET
    103 714 Emergency unlocking CET
  • Cover for read head and actuator CET
    098 808 CET Abdeckung rechts
    098 807 CET Abdeckung links
  • Wire front release (bowden) for non-contact safety switches CET-AR
    109 352 BW-CET-C-3000-F-109352
  • Handle for wire front release (Bowden)
    099 795 BW-Griff
  • Lock for emergency unlocking with manual return for safety switches TP/STP
    099 434 Ersatzschlüssel TP gleichschließend
Connection material
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-AR/CES-AP-C01
    100 177 C-M12F08-08X025PV05,0-ZN-100177
    100 178 C-M12F08-08X025PV10,0-ZN-100178
    100 179 C-M12F08-08X025PV20,0-ZN-100179
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-ART/CES-AP
    100 183 C-M12F05-05X034PV05,0-ZN-100183
    100 184 C-M12F05-05X034PV10,0-ZN-100184
    100 185 C-M12F05-05X034PV20,0-ZN-100185
  • Connection cables with 2 plug connectors M12 for safety switch CES-AR/CET-AR
    100 180 C-M12F05-05X034PV05,0-M12M05-100180
    100 181 C-M12F05-05X034PV10,0-M12M05-100181
    100 182 C-M12F05-05X034PV20,0-M12M05-100182
  • Bridging plug M12
    097 645 Bridging plug
  • Y-distributor M12
    097 627 Y-distributor M12
  • Connection cables with female plug M8 and flying lead for CES-AR-C.2
    106 671 C-M08F08-08X014PU05,0-ES-106671
    106 672 C-M08F08-08X014PU10,0-ES-106672
    106 673 C-M08F08-08X014PU20,0-ES-106673
    110 933 C-M08F08-08X014PV205,0-ES-110933
    110 934 C-M08F08-08X014PV210,0-ES-110934
    110 935 C-M08F08-08X014PV210,0-ES-110935
    111 603 C-M08F08-08X014PV220,0-ES-111603
  • Y-distributor M12 with connection cable
    111 696 Y-Verteiler M12 mit Anschlussleitung
+Non-contact safety switch CET-AR-..., M12, with lockout bar
Actuator
  • Actuator CET-A-BWK-50X
    096 327 CET-A-BWK-50X
Bolt
  • Bolt CET-A-C
    104 309 Bolt CET-A-C
  • Bolt CET-A-C/F with escape release
    106 172 Bolt CET-A-C/F
Fastening
  • Mounting plate EMP-L-... for safety switches CET
    106 695 EMP-L-CET
  • Mounting plate EMP-B-... for actuator CET
    106 694 EMP-B-CET
  • Safety screws M5 x 16 for actuator CET-A-BWK-50X
    073 456 M5x16/V100
  • Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...
    074 063 M4x14/V100
Add-On
  • Mechanical key release for read head CET
    098 850 Schlüsselhilfsentriegelung
    099 434 Ersatzschlüssel
  • Emergency unlocking for read head CET
    103 714 Emergency unlocking CET
  • Cover for read head and actuator CET
    098 808 CET Abdeckung rechts
    098 807 CET Abdeckung links
  • Wire front release (bowden) for non-contact safety switches CET-AR
    109 352 BW-CET-C-3000-F-109352
  • Handle for wire front release (Bowden)
    099 795 BW-Griff
  • Lock for emergency unlocking with manual return for safety switches TP/STP
    099 434 Ersatzschlüssel TP gleichschließend
Connection material
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-AR/CES-AP-C01
    100 177 C-M12F08-08X025PV05,0-ZN-100177
    100 178 C-M12F08-08X025PV10,0-ZN-100178
    100 179 C-M12F08-08X025PV20,0-ZN-100179
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-ART/CES-AP
    100 183 C-M12F05-05X034PV05,0-ZN-100183
    100 184 C-M12F05-05X034PV10,0-ZN-100184
    100 185 C-M12F05-05X034PV20,0-ZN-100185
  • Connection cables with 2 plug connectors M12 for safety switch CES-AR/CET-AR
    100 180 C-M12F05-05X034PV05,0-M12M05-100180
    100 181 C-M12F05-05X034PV10,0-M12M05-100181
    100 182 C-M12F05-05X034PV20,0-M12M05-100182
  • Bridging plug M12
    097 645 Bridging plug
  • Y-distributor M12
    097 627 Y-distributor M12
  • Connection cables with female plug M8 and flying lead for CES-AR-C.2
    106 671 C-M08F08-08X014PU05,0-ES-106671
    106 672 C-M08F08-08X014PU10,0-ES-106672
    106 673 C-M08F08-08X014PU20,0-ES-106673
    110 933 C-M08F08-08X014PV205,0-ES-110933
    110 934 C-M08F08-08X014PV210,0-ES-110934
    110 935 C-M08F08-08X014PV210,0-ES-110935
    111 603 C-M08F08-08X014PV220,0-ES-111603
  • Y-distributor M12 with connection cable
    111 696 Y-Verteiler M12 mit Anschlussleitung
+Non-contact safety switch CET-AR-..., M12, with Bowden wire
Actuator
  • Actuator CET-A-BWK-50X
    096 327 CET-A-BWK-50X
Bolt
  • Bolt CET-A-C
    104 309 Bolt CET-A-C
  • Bolt CET-A-C/F with escape release
    106 172 Bolt CET-A-C/F
Fastening
  • Mounting plate EMP-L-... for safety switches CET
    106 695 EMP-L-CET
  • Mounting plate EMP-B-... for actuator CET
    106 694 EMP-B-CET
  • Safety screws M5 x 16 for actuator CET-A-BWK-50X
    073 456 M5x16/V100
  • Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...
    074 063 M4x14/V100
Add-On
  • Mechanical key release for read head CET
    098 850 Schlüsselhilfsentriegelung
    099 434 Ersatzschlüssel
  • Emergency unlocking for read head CET
    103 714 Emergency unlocking CET
  • Cover for read head and actuator CET
    098 808 CET Abdeckung rechts
    098 807 CET Abdeckung links
  • Wire front release (bowden) for non-contact safety switches CET-AR
    109 352 BW-CET-C-3000-F-109352
  • Handle for wire front release (Bowden)
    099 795 BW-Griff
  • Lock for emergency unlocking with manual return for safety switches TP/STP
    099 434 Ersatzschlüssel TP gleichschließend
Connection material
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-AR/CES-AP-C01
    100 177 C-M12F08-08X025PV05,0-ZN-100177
    100 178 C-M12F08-08X025PV10,0-ZN-100178
    100 179 C-M12F08-08X025PV20,0-ZN-100179
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-ART/CES-AP
    100 183 C-M12F05-05X034PV05,0-ZN-100183
    100 184 C-M12F05-05X034PV10,0-ZN-100184
    100 185 C-M12F05-05X034PV20,0-ZN-100185
  • Connection cables with 2 plug connectors M12 for safety switch CES-AR/CET-AR
    100 180 C-M12F05-05X034PV05,0-M12M05-100180
    100 181 C-M12F05-05X034PV10,0-M12M05-100181
    100 182 C-M12F05-05X034PV20,0-M12M05-100182
  • Bridging plug M12
    097 645 Bridging plug
  • Y-distributor M12
    097 627 Y-distributor M12
  • Connection cables with female plug M8 and flying lead for CES-AR-C.2
    106 671 C-M08F08-08X014PU05,0-ES-106671
    106 672 C-M08F08-08X014PU10,0-ES-106672
    106 673 C-M08F08-08X014PU20,0-ES-106673
    110 933 C-M08F08-08X014PV205,0-ES-110933
    110 934 C-M08F08-08X014PV210,0-ES-110934
    110 935 C-M08F08-08X014PV210,0-ES-110935
    111 603 C-M08F08-08X014PV220,0-ES-111603
  • Y-distributor M12 with connection cable
    111 696 Y-Verteiler M12 mit Anschlussleitung
+Non-contact safety switch CET-AR-..., M12, with Bowden wire and escape release
Actuator
  • Actuator CET-A-BWK-50X
    096 327 CET-A-BWK-50X
Bolt
  • Bolt CET-A-C
    104 309 Bolt CET-A-C
  • Bolt CET-A-C/F with escape release
    106 172 Bolt CET-A-C/F
Fastening
  • Mounting plate EMP-L-... for safety switches CET
    106 695 EMP-L-CET
  • Mounting plate EMP-B-... for actuator CET
    106 694 EMP-B-CET
  • Safety screws M5 x 16 for actuator CET-A-BWK-50X
    073 456 M5x16/V100
  • Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...
    074 063 M4x14/V100
Add-On
  • Mechanical key release for read head CET
    098 850 Schlüsselhilfsentriegelung
    099 434 Ersatzschlüssel
  • Emergency unlocking for read head CET
    103 714 Emergency unlocking CET
  • Cover for read head and actuator CET
    098 808 CET Abdeckung rechts
    098 807 CET Abdeckung links
  • Wire front release (bowden) for non-contact safety switches CET-AR
    109 352 BW-CET-C-3000-F-109352
  • Handle for wire front release (Bowden)
    099 795 BW-Griff
  • Lock for emergency unlocking with manual return for safety switches TP/STP
    099 434 Ersatzschlüssel TP gleichschließend
Connection material
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-AR/CES-AP-C01
    100 177 C-M12F08-08X025PV05,0-ZN-100177
    100 178 C-M12F08-08X025PV10,0-ZN-100178
    100 179 C-M12F08-08X025PV20,0-ZN-100179
  • Connection cables with plug connector M12 for safety switch CES-AR/CET-ART/CES-AP
    100 183 C-M12F05-05X034PV05,0-ZN-100183
    100 184 C-M12F05-05X034PV10,0-ZN-100184
    100 185 C-M12F05-05X034PV20,0-ZN-100185
  • Connection cables with 2 plug connectors M12 for safety switch CES-AR/CET-AR
    100 180 C-M12F05-05X034PV05,0-M12M05-100180
    100 181 C-M12F05-05X034PV10,0-M12M05-100181
    100 182 C-M12F05-05X034PV20,0-M12M05-100182
  • Bridging plug M12
    097 645 Bridging plug
  • Y-distributor M12
    097 627 Y-distributor M12
  • Connection cables with female plug M8 and flying lead for CES-AR-C.2
    106 671 C-M08F08-08X014PU05,0-ES-106671
    106 672 C-M08F08-08X014PU10,0-ES-106672
    106 673 C-M08F08-08X014PU20,0-ES-106673
    110 933 C-M08F08-08X014PV205,0-ES-110933
    110 934 C-M08F08-08X014PV210,0-ES-110934
    110 935 C-M08F08-08X014PV210,0-ES-110935
    111 603 C-M08F08-08X014PV220,0-ES-111603
  • Y-distributor M12 with connection cable
    111 696 Y-Verteiler M12 mit Anschlussleitung
+Non-contact safety switch CET-AR-..., RC18
Actuator
  • Actuator CET-A-BWK-50X
    096 327 CET-A-BWK-50X
Bolt
  • Bolt CET-A-C
    104 309 Bolt CET-A-C
  • Bolt CET-A-C/F with escape release
    106 172 Bolt CET-A-C/F
Fastening
  • Mounting plate EMP-L-... for safety switches CET
    106 695 EMP-L-CET
  • Mounting plate EMP-B-... for actuator CET
    106 694 EMP-B-CET
  • Safety screws M5 x 16 for actuator CET-A-BWK-50X
    073 456 M5x16/V100
  • Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...
    074 063 M4x14/V100
Add-On
  • Mechanical key release for read head CET
    098 850 Schlüsselhilfsentriegelung
    099 434 Ersatzschlüssel
  • Emergency unlocking for read head CET
    103 714 Emergency unlocking CET
  • Cover for read head and actuator CET
    098 808 CET Abdeckung rechts
    098 807 CET Abdeckung links
  • Wire front release (bowden) for non-contact safety switches CET-AR
    109 352 BW-CET-C-3000-F-109352
  • Handle for wire front release (Bowden)
    099 795 BW-Griff
  • Lock for emergency unlocking with manual return for safety switches TP/STP
    099 434 Ersatzschlüssel TP gleichschließend
Connection material
+Non-contact safety switch CET-AR-..., RC18, with Bowden wire
Actuator
  • Actuator CET-A-BWK-50X
    096 327 CET-A-BWK-50X
Bolt
  • Bolt CET-A-C
    104 309 Bolt CET-A-C
  • Bolt CET-A-C/F with escape release
    106 172 Bolt CET-A-C/F
Fastening
  • Mounting plate EMP-L-... for safety switches CET
    106 695 EMP-L-CET
  • Mounting plate EMP-B-... for actuator CET
    106 694 EMP-B-CET
  • Safety screws M5 x 16 for actuator CET-A-BWK-50X
    073 456 M5x16/V100
  • Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...
    074 063 M4x14/V100
Add-On
  • Mechanical key release for read head CET
    098 850 Schlüsselhilfsentriegelung
    099 434 Ersatzschlüssel
  • Emergency unlocking for read head CET
    103 714 Emergency unlocking CET
  • Cover for read head and actuator CET
    098 808 CET Abdeckung rechts
    098 807 CET Abdeckung links
  • Wire front release (bowden) for non-contact safety switches CET-AR
    109 352 BW-CET-C-3000-F-109352
  • Handle for wire front release (Bowden)
    099 795 BW-Griff
  • Lock for emergency unlocking with manual return for safety switches TP/STP
    099 434 Ersatzschlüssel TP gleichschließend
Connection material
+Non-contact safety switch CET-AR-..., RC18, with escape release
Actuator
  • Actuator CET-A-BWK-50X
    096 327 CET-A-BWK-50X
Bolt
  • Bolt CET-A-C
    104 309 Bolt CET-A-C
  • Bolt CET-A-C/F with escape release
    106 172 Bolt CET-A-C/F
Fastening
  • Mounting plate EMP-L-... for safety switches CET
    106 695 EMP-L-CET
  • Mounting plate EMP-B-... for actuator CET
    106 694 EMP-B-CET
  • Safety screws M5 x 16 for actuator CET-A-BWK-50X
    073 456 M5x16/V100
  • Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...
    074 063 M4x14/V100
Add-On
  • Mechanical key release for read head CET
    098 850 Schlüsselhilfsentriegelung
    099 434 Ersatzschlüssel
  • Emergency unlocking for read head CET
    103 714 Emergency unlocking CET
  • Cover for read head and actuator CET
    098 808 CET Abdeckung rechts
    098 807 CET Abdeckung links
  • Wire front release (bowden) for non-contact safety switches CET-AR
    109 352 BW-CET-C-3000-F-109352
  • Handle for wire front release (Bowden)
    099 795 BW-Griff
  • Lock for emergency unlocking with manual return for safety switches TP/STP
    099 434 Ersatzschlüssel TP gleichschließend
Connection material
+Non-contact safety switch CET-AR-..., RC18, with Bowden wire and escape release
Actuator
  • Actuator CET-A-BWK-50X
    096 327 CET-A-BWK-50X
Bolt
  • Bolt CET-A-C
    104 309 Bolt CET-A-C
  • Bolt CET-A-C/F with escape release
    106 172 Bolt CET-A-C/F
Fastening
  • Mounting plate EMP-L-... for safety switches CET
    106 695 EMP-L-CET
  • Mounting plate EMP-B-... for actuator CET
    106 694 EMP-B-CET
  • Safety screws M5 x 16 for actuator CET-A-BWK-50X
    073 456 M5x16/V100
  • Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...
    074 063 M4x14/V100
Add-On
  • Mechanical key release for read head CET
    098 850 Schlüsselhilfsentriegelung
    099 434 Ersatzschlüssel
  • Emergency unlocking for read head CET
    103 714 Emergency unlocking CET
  • Cover for read head and actuator CET
    098 808 CET Abdeckung rechts
    098 807 CET Abdeckung links
  • Wire front release (bowden) for non-contact safety switches CET-AR
    109 352 BW-CET-C-3000-F-109352
  • Handle for wire front release (Bowden)
    099 795 BW-Griff
  • Lock for emergency unlocking with manual return for safety switches TP/STP
    099 434 Ersatzschlüssel TP gleichschließend
Connection material
+Non-contact safety switch CET-AR-..., RC18, with lockout bar
Actuator
  • Actuator CET-A-BWK-50X
    096 327 CET-A-BWK-50X
Bolt
  • Bolt CET-A-C
    104 309 Bolt CET-A-C
  • Bolt CET-A-C/F with escape release
    106 172 Bolt CET-A-C/F
Fastening
  • Mounting plate EMP-L-... for safety switches CET
    106 695 EMP-L-CET
  • Mounting plate EMP-B-... for actuator CET
    106 694 EMP-B-CET
  • Safety screws M5 x 16 for actuator CET-A-BWK-50X
    073 456 M5x16/V100
  • Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...
    074 063 M4x14/V100
Add-On
  • Mechanical key release for read head CET
    098 850 Schlüsselhilfsentriegelung
    099 434 Ersatzschlüssel
  • Emergency unlocking for read head CET
    103 714 Emergency unlocking CET
  • Cover for read head and actuator CET
    098 808 CET Abdeckung rechts
    098 807 CET Abdeckung links
  • Wire front release (bowden) for non-contact safety switches CET-AR
    109 352 BW-CET-C-3000-F-109352
  • Handle for wire front release (Bowden)
    099 795 BW-Griff
  • Lock for emergency unlocking with manual return for safety switches TP/STP
    099 434 Ersatzschlüssel TP gleichschließend
Connection material
+Manuals
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Safety Information and Maintenance CET-AR/CET-AP105517
07
03/12
DEENFR
ESIT
PDF 183 KB
Operating Instructions Safety Switch CET.-AR-...-CH-... (Multicode)110789
05
03/12
DEPDF 2950 KB
ENPDF 2939 KB
FRPDF 2956 KB
ESPDF 2958 KB
ITPDF 2947 KB
Operating Instructions Safety Switch CET.-AR-...-AH-... (Unicode)110788
05
03/12
DEPDF 3144 KB
ENPDF 3123 KB
FRPDF 3122 KB
ESPDF 3127 KB
ITPDF 3128 KB
+Catalogs
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Berührungsloses Sicherheitssystem CES076609
15
09/11
DEPDF 25865 KB
Non-Contact Safety System CES076649
15
09/11
ENPDF 25794 KB
Système de sécurité sans contact CES086818
15
09/11
FRPDF 25835 KB
Sistema de seguridad sin contacto CES086819
15
09/11
ESPDF 26530 KB
Sistema di sicurezza senza contatto CES076704
08
09/08
ITPDF 13279 KB
+Declarations of conformity
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Title110802
04
PDF 232 KB
+CAD data
  • 103 418 CET1-AR-CRA-AH-50X-SG-103418
  • 105 763 CET1-AR-CRA-CH-50X-SG-105763
  • 105 764 CET1-AR-CRA-CH-50S-SG-105764
  • 105 802 CET1-AR-CRA-AH-50S-SG-105802
  • 106 159 CET1-AR-CRA-AH-50F-SG-106159
  • 106 275 CET1-AR-CDA-AH-50X-SG-106275
  • 106 616 CET1-AR-CRA-AH-50A-SG-106616
  • 109 015 CET1-AR-CRA-CH-50X-SG-C2290-109015
  • 109 075 CET2-AR-CRA-AH-50S-SG-109075
  • 109 231 CET1-AR-CDA-CH-50X-SG-109231
  • 109 401 CET3-AR-CRA-AH-50X-SG-109401
  • 109 941 CET2-AR-CRA-CH-50F-SG-C2312-109941
  • 110 082 CET2-AR-CRA-CH-50X-SG-110082
  • 110 103 CET3-AR-CRA-AH-50X-SH-110103
  • 110 104 CET3-AR-CRA-CH-50X-SH-110104
  • 110 114 CET3-AR-CRA-CH-50X-SG-C2290-110114
  • 110 203 CET1-AR-CRA-AH-50X-SH-110203
  • 110 204 CET1-AR-CRA-CH-50X-SH-110204
  • 110 205 CET2-AR-CRA-AH-50X-SH-110205
  • 110 206 CET2-AR-CRA-CH-50X-SH-110206
  • 110 240 CET2-AR-CRA-AH-50X-SG-110240
  • 110 241 CET1-AR-CRA-CH-50F-SG-110241
  • 110 905 CET3-AR-CRA-CH-50F-SG-C2290-110905
  • 110 906 CET3-AR-CRA-CH-50X-SG-110906
  • 110 907 CET3-AR-CRA-CH-50F-SG-110907
  • 110 943 CET1-AR-CRA-AH-50F-SH-C2312-110943
  • 111 725 CET3-AR-CRA-AH-50X-SH-111725
  • 111 766 CET1-AR-CRA-AH-50F-SG-C2333-111766
  • 112 121 CET1-AR-CRA-AH-50X-SG-C2333-112121
  • 112 921 CET3-AR-CRA-CH-50F-SG-C2333-112921
  • 112 992 CET3-AR-CRA-CH-50S-SG-112992
  • 113 021 CET1-AR-CRA-AH-50F-SH-C2312-110943
  • 113 022 CET1-AR-CRA-AH-50X-SH-C2290-113022
  • 113 023 CET3-AR-CRA-AH-50F-SH-C2353-113023
  • 113 024 CET3-AR-CRA-AH-50X-SH-C2290-113024
  • 113 139 CET3-AR-CRA-AH-50X-SG-C2290-113139
  • 113 148 CET3-AR-CRA-AH-50F-SH-113148
  • 113 151 CET3-AR-CRA-AH-50X-SH-C2333-113151