Read heads CET-AX- Read head with guard locking and guard lock monitoring
- Up to category 4
- High locking forces up to 6500 N
- Integrated transponder coding
- Metal housing
Design and functionalityWith the read head CET-AX, EUCHNER provides monitored guard locking based on non-contact transponder technology. This means that the switch can also be used on systems with overtravelling machine movements for the personal protection. When closing the safety guard (hinged or sliding door), the spring-loaded transponder in the actuator is inserted into the recess on the read head. The read head detects the closed safety guard in its guard locked position. The CES evaluation electronics enables the safety circuit when the safety guard is locked. When the moving parts of the machine come to a standstill, the solenoid integrated into the read head can be activated by a safe standstill monitor or by a timer relay. The solenoid's plunger then raises the spring-loaded transponder, which allows the safety guard to be opened. |  |  | more information |
Use of the read head even in extremely harsh environmentsDue to the extremely robust metal housing, the switch is suitable for the harshest ambient conditions and when guard locked achieves a locking force of 6500 N - a characteristic that is advantageous particularly for heavy doors. With the safety guard closed, the CET-AX provides around ± 5 mm of freedom of movement in all 3 directions (x, y, z direction) – even if the safety door drops over time it will not be necessary to re-adjust the actuator. The insertion slide can be rotated in 90° steps. As a result the switch is suitable for doors hinged on the right and left. Different versionsAlong with the standard version with a single insertion slide, there is also the CET-AX with a double insertion slide that is perfectly suited to swing doors and rotary tables. That is, wherever the approach is from two sides and where the read head must also be "passed over". As an option, EUCHNER also offers versions with escape release. This feature enables people locked in to open the locked safety guard from the inside in an emergency. The range is supplemented by versions with different plug variants and freely configurable LED control. Your advantages- Robust die-cast zinc housing for harsh environments
- Suitable for heavy doors
- High protection against tampering
- Actuator with large freedom of movement
- No precise door adjustment necessary
- Low wiring effort
- High degree of protection IP67
- Suitable for the highest safety requirements
|
 | Read head CET1-AX-..., M12, with guard locking and guard lock monitoring |
- Read head with guard locking
- Locking force up to 6,500 N
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- 2 LEDs (1 freely configurable)
Mechanical release
Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer)
Approach direction
Horizontal
Can be adjusted in 90° steps
Solenoid operating voltage
Guard locking types
| CET1 | Closed-circuit current principle, release by applying voltage to the guard locking solenoid. |
LED function display
| Red LED | Illuminates when solenoid switched on | | Green LED | freely configurable |
Category according to EN ISO 13849-1
Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position.
Notes
- Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
- The read head CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X. The actuator must be ordered separately.
Plug connector (view of connection side)
|
PIN
|
Function
|
Wire color connection cable
|
|---|
With plug connector M12
|
1
|
H1, read head data wire
|
WH
| |
|
2
|
H2, read head data wire
|
BN
| |
3
|
SH, data wire screen
|
(Screen)
| |
4
|
LED 2 freely configurable, 24 V
|
YE
| |
5
|
0V
|
GY
| |
6
|
M+, UB/24 V solenoid
|
PK
| |
7
|
M-, 0 V/GND solenoid
|
BU
| |
8
|
Housing
|
RD
|
Order numbers:- 095 735 CET1-AX-LRA-00-50X-SA
- 104 051 CET1-AX-LRA-00-50X-SF
| Read head CET... with plug connector M12 Terminal assignment With plug connector M12  |
 | Read head CET1-AX-... M12, with guard locking and guard lock monitoring, 2 freely configurable LEDs |
- Read head with guard locking
- Locking force up to 6,500 N
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- 2 freely configurable LEDs
Mechanical release
Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer)
Approach direction
Horizontal
Can be adjusted in 90° steps
Solenoid operating voltage
Guard locking types
| CET1 | Closed-circuit current principle, release by applying voltage to the guard locking solenoid. |
LED function display
| Red LED | illuminates when solenoid is switched on or freely configurable | | Green LED | freely configurable |
Category according to EN ISO 13849-1
Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position.
Notes
- Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
- The read head CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X. The actuator must be ordered separately.
Plug connector (view of connection side)
|
PIN
|
Function
|
Wire color connection cable
|
With plug connector M12 and 2 freely configurable LEDs
|
1
|
H1, read head data wire
|
BN
| |
|
2
|
H2, read head data wire
|
WH
| |
3
|
SH, data wire screen
|
(Screen)
| |
4
|
LED 2 freely configurable, 24 V
|
YE
| |
5
|
LED 1 freely configurable, 24 V
|
GY
| |
6
|
UCM, UB/24 V solenoid
|
PK
| |
7
|
0 V/GND solenoid and LEDs
|
BU
| |
8
|
Housing
|
RD
|
Order numbers:- 104 062 CET1-AX-LRA-00-50L-SA
| Read head CET... with plug connector M12 Terminal assignment With plug connector M12 and 2 freely configurable LEDs  |
 | Read head CET2-AX-... M12, with guard locking and guard lock monitoring |
- Read head with guard locking
- Locking force up to 6,500 N
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
Mechanical release
Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer)
Approach direction
Horizontal
Can be adjusted in 90° steps
Solenoid operating voltage
Guard locking types
| CET2 | Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force. |
LED function display
| Red LED | Illuminates when solenoid switched on | | Green LED | freely configurable |
Category according to EN ISO 13849-1
Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position.
Notes
- Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
- The read head CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X. The actuator must be ordered separately.
Plug connector (view of connection side)
|
PIN
|
Function
|
Wire color connection cable
|
|---|
With plug connector M12
|
1
|
H1, read head data wire
|
WH
| |
|
2
|
H2, read head data wire
|
BN
| |
3
|
SH, data wire screen
|
(Screen)
| |
4
|
LED 2 freely configurable, 24 V
|
YE
| |
5
|
0V
|
GY
| |
6
|
UCM, UB/24 V solenoid
|
PK
| |
7
|
0 V/GND solenoid and LEDs
|
BU
| |
8
|
Housing
|
RD
|
Order numbers:- 106 039 CET2-AX-LRA-00-50X-SA
| Read head CET2... with plug connector M12 Terminal assignment With plug connector M12 and 2 LEDs, of these 1 freely configurable LED  |
 | Read head CET1-AX-... M12, with guard locking and guard lock monitoring, double insertion slide |
- Read head with guard locking
- Locking force up to 6,500 N
- Up to category 4/PL e according to EN ISO 13849-1
- With double insertion slide
- With plug connector M12
Mechanical release
Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).
Approach direction
Horizontal
Can be adjusted in 90° steps
Solenoid operating voltage
Guard locking types
| CET1 | Closed-circuit current principle, release by applying voltage to the guard locking solenoid. |
LED function display
| Red LED | Illuminates when solenoid switched on | | Green LED | freely configurable |
Category according to EN ISO 13849-1
Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position.
Notes
- Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
- The read head CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X. The actuator must be ordered separately.
Plug connector (view of connection side)
|
PIN
|
Function
|
Wire color connection cable
|
|---|
With plug connector M12
|
1
|
H1, read head data wire
|
WH
| |
|
2
|
H2, read head data wire
|
BN
| |
3
|
SH, data wire screen
|
(Screen)
| |
4
|
LED 2 freely configurable, 24 V
|
YE
| |
5
|
0V
|
GY
| |
6
|
UCM, UB/24 V solenoid
|
PK
| |
7
|
0 V/GND solenoid and LEDs
|
BU
| |
8
|
Housing
|
RD
|
Order numbers:- 100 399 CET1-AX-LDA-00-50X-SE
| Read head CET... with plug connector M12 Terminal assignment Plug connector M12  |
 | Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release |
- Read head with guard locking
- Locking force up to 6,500 N
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- With escape release
Mechanical release
Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).
Escape release
Is used for the manual release of the guard locking from within the danger area without tools.
Approach direction
Horizontal
Can be adjusted in 90° steps
Solenoid operating voltage
Guard locking types
| CET1 | Closed-circuit current principle, release by applying voltage to the guard locking solenoid. |
LED function display
| Red LED | Illuminates when solenoid switched on | | Green LED | freely configurable |
Category according to EN ISO 13849-1
Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position.
Notes
- Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
- The read head CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X. The actuator must be ordered separately.
Plug connector (view of connection side)
|
PIN
|
Function
|
Wire color connection cable
|
|---|
With plug connector M12
|
1
|
H1, read head data wire
|
WH
| |
|
2
|
H2, read head data wire
|
BN
| |
3
|
SH, data wire screen
|
(Screen)
| |
4
|
LED 2 freely configurable, 24 V
|
YE
| |
5
|
0V
|
GY
| |
6
|
UCM, UB/24 V solenoid
|
PK
| |
7
|
0 V/GND solenoid and LEDs
|
BU
| |
8
|
Housing
|
RD
|
Order numbers:- 102 161 CET1-AX-LRA-00-50F-SA
| Read head CET... With plug connector M12 and escape release Terminal assignment Plug connector M12  |
 | Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release, double insertion slide |
- Read head with guard locking
- Locking force up to 6,500 N
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- With escape release
Mechanical release
Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).
Escape release
Is used for the manual release of the guard locking from within the danger area without tools.
Similar to figure
Approach direction
Horizontal
Can be adjusted in 90° steps
Solenoid operating voltage
Guard locking types
| CET1 | Closed-circuit current principle, release by applying voltage to the guard locking solenoid. |
LED function display
| Red LED | Illuminates when solenoid switched on | | Green LED | freely configurable |
Category according to EN ISO 13849-1
Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position.
Notes
- Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
- The read head CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X. The actuator must be ordered separately.
Plug connector (view of connection side)
|
PIN
|
Function
|
Wire color connection cable
|
|---|
With plug connector M12
|
1
|
H1, read head data wire
|
WH
| |
|
2
|
H2, read head data wire
|
BN
| |
3
|
SH, data wire screen
|
(Screen)
| |
4
|
LED 2 freely configurable, 24 V
|
YE
| |
5
|
0V
|
GY
| |
6
|
UCM, UB/24 V solenoid
|
PK
| |
7
|
0 V/GND solenoid and LEDs
|
BU
| |
8
|
Housing
|
RD
|
Order numbers:- 103 750 CET1-AX-LDA-00-50F-SA
| Read head CET... With plug connector M12 and escape release Terminal assignment Plug connector M12  |
 | Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release and lockout mechanism |
- Read head with guard locking
- Locking force up to 6,500 N
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- With escape release
- With lockout mechanism
Mechanical release
Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).
Escape release
Is used for the manual release of the guard locking from within the danger area without tools.
Similar to figure
Approach direction
Horizontal
Can be adjusted in 90° steps
Solenoid operating voltage
Guard locking types
| CET1 | Closed-circuit current principle, release by applying voltage to the guard locking solenoid. |
LED function display
| Red LED | Illuminates when solenoid switched on | | Green LED | freely configurable |
Category according to EN ISO 13849-1
Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position.
Notes
- Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
- The read head CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X. The actuator must be ordered separately.
Plug connector (view of connection side)
|
PIN
|
Function
|
Wire color connection cable
|
|---|
With plug connector M12
|
1
|
H1, read head data wire
|
WH
| |
|
2
|
H2, read head data wire
|
BN
| |
3
|
SH, data wire screen
|
(Screen)
| |
4
|
LED 2 freely configurable, 24 V
|
YE
| |
5
|
0V
|
GY
| |
6
|
UCM, UB/24 V solenoid
|
PK
| |
7
|
0 V/GND solenoid and LEDs
|
BU
| |
8
|
Housing
|
RD
|
Order numbers:- 111 918 CET1-AX-LRA-00-50F-SA-C2333-111918
| Read head CET... with plug connector M12, escape release and lockout mechanism Terminal assignment Plug connector M12  |
 | Read head CET1-AX-... M12, with guard locking and guard lock monitoring and lockout mechanism |
- Read head with guard locking
- Locking force up to 6,500 N
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M12
- With lockout mechanism
Mechanical release
Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).
Similar to figure
Approach direction
Horizontal
Can be adjusted in 90° steps
Lockout mechanism
The lockout mechanism can be used to prevent maintenance personnel from being unintentionally locked in the danger area, for example.
Important: The lockout mechanism is not a safety function.
Solenoid operating voltage
Guard locking types
| CET1 | Closed-circuit current principle, release by applying voltage to the guard locking solenoid. |
LED function display
| Red LED | Illuminates when solenoid switched on | | Green LED | freely configurable |
Category according to EN ISO 13849-1
Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position.
Notes
- Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
- The read head CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X. The actuator must be ordered separately.
Plug connector (view of connection side)
|
PIN
|
Function
|
Wire color connection cable
|
|---|
With plug connector M12
|
1
|
H1, read head data wire
|
WH
| |
|
2
|
H2, read head data wire
|
BN
| |
3
|
SH, data wire screen
|
(Screen)
| |
4
|
LED 2 freely configurable, 24 V
|
YE
| |
5
|
0V
|
GY
| |
6
|
UCM, UB/24 V solenoid
|
PK
| |
7
|
0 V/GND solenoid and LEDs
|
BU
| |
8
|
Housing
|
RD
|
Order numbers:- 111 917 CET1-AX-LRA-00-50X-SA-C2333-111917
| Read head CET... with plug connector M12 and lockout mechanism Terminal assignment Plug connector M12  |
 | Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring |
- Read head with guard locking
- Locking force up to 6,500 N
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M8
Mechanical release
Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).
Similar to figure
Approach direction
Horizontal
Can be adjusted in 90° steps
Solenoid operating voltage
Guard locking types
| CET1 | Closed-circuit current principle, release by applying voltage to the guard locking solenoid. |
LED function display
| Red LED | Illuminates when solenoid switched on | | Green LED | freely configurable |
Category according to EN ISO 13849-1
Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position.
Notes
- Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
- The read head CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X. The actuator must be ordered separately.
Plug connector (view of connection side)
|
PIN
|
Function
|
Wire color connection cable
|
|---|
With 2 plug connectors M8
|
S 1.1
|
H1, read head data wire
|
BN
| |
|
S 1.3
|
H2, read head data wire
|
WH
| |
S 1.4
|
SH, data wire screen
|
BU
| |
|
|
| |
S 2.1
|
UCM, UB/24 V solenoid
|
BN
| |
S 2.2
|
0V
|
WH
| |
S 2.3
|
0 V/GND solenoid
|
BU
| |
S 2.4
|
LED 2 freely configurable, 24 V
|
BK
|
Order numbers:- 102 988 CET1-AX-LRA-00-50X-SC
| Read head CET... with 2 plug connectors M8 Terminal assignment With 2 plug connectors M8  |
 | Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring, double insertion slide |
- Read head with guard locking
- Locking force up to 6,500 N
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M8
- With double insertion slide
Mechanical release
Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).
Similar to figure
Approach direction
Horizontal
Can be adjusted in 90° steps
Solenoid operating voltage
Guard locking types
| CET1 | Closed-circuit current principle, release by applying voltage to the guard locking solenoid. |
LED function display
| Red LED | Illuminates when solenoid switched on | | Green LED | freely configurable |
Category according to EN ISO 13849-1
Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position.
Notes
- Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
- The read head CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X. The actuator must be ordered separately.
Plug connector (view of connection side)
|
PIN
|
Function
|
Wire color connection cable
|
|---|
With 2 plug connectors M8
|
S 1.1
|
Read head data wire
|
BN
| |
|
S 1.3
|
Read head data wire
|
WH
| |
S 1.4
|
SH, data wire screen
|
BU
| |
|
|
| |
S 2.1
|
UCM, UB/24 V solenoid
|
BN
| |
S 2.2
|
0V
|
WH
| |
S 2.3
|
0 V/GND solenoid
|
BU
| |
S 2.4
|
LED 2 freely configurable, 24 V
|
BK
|
Order numbers:- 103 444 CET1-AX-LDA-00-50X-SC
| Read head CET... with 2 plug connectors M8 Terminal assignment With 2 plug connectors M8  |
 | Read head CET2-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring |
- Read head with guard locking
- Locking force up to 6,500 N
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M8
Mechanical release
Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer).
Similar to figure
Approach direction
Horizontal
Can be adjusted in 90° steps
Wire front release (optional)
The wire front release (bowden) permits remote release of the guard locking via a pull rope. Flexible routing of the pull wire permits release of the guard locking in inaccessible installation situations.
Solenoid operating voltage
Guard locking types
| CET2 | Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force. |
LED function display
| Red LED | Illuminates when solenoid switched on | | Green LED | freely configurable |
Category according to EN ISO 13849-1
Important: The category in accordance with EN ISO 13849-1 is dependent on the evaluation unit used and on the installation position.
Notes
- Special connection cables from EUCHNER are required for the connection. Please take into account in the order!
- The read head CET is only allowed to be operated in conjunction with the actuator CET-A-BWK-50X. The actuator must be ordered separately.
Plug connector (view of connection side)
|
PIN
|
Function
|
Wire color connection cable
|
|---|
With 2 plug connectors M8
|
S 1.1
|
Read head data wire
|
BN
| |
|
S 1.3
|
Read head data wire
|
WH
| |
S 1.4
|
SH, data wire screen
|
BU
| |
|
|
| |
S 2.1
|
UCM, UB/24 V solenoid
|
BN
| |
S 2.2
|
0V
|
WH
| |
S 2.3
|
0 V/GND solenoid
|
BU
| |
S 2.4
|
LED 2 freely configurable, 24 V
|
BK
|
Order numbers:- 109 932 CET2-AX-LRA-00-50X-SC
| Read head CET2... with 2 plug connectors M8 Terminal assignment With 2 plug connectors M8  |
Click on the product to view the available accessories!  | Read head CET1-AX-..., M12, with guard locking and guard lock monitoring |
Actuator Bolt Fastening - Mounting plate EMP-L-... for safety switches CET
- Mounting plate EMP-B-... for actuator CET
- Safety screws M5 x 16 for actuator CET-A-BWK-50X
Add-On - Mechanical key release for read head CET
098 850 Mechanical key release - Emergency unlocking for read head CET
103 714 Emergency unlocking CET - Cover for read head and actuator CET
098 808 CET Abdeckung rechts098 807 CET Abdeckung links
Connection material - Connection cables with plug connector M12 for CET...
099 633 C-M12F08-07X025PV10,0-MA-099633099 634 C-M12F08-07X025PV20,0-MA-099634103 115 C-M12F08-07X025PV25,0-MA-103115100 456 C-M12F08-07X025PV10,0-MA-100456105 071 C-M12F08-07X025PV20,0-MA-105071102 218 C-M12F08-07X025PU10,0-MA-102218103 782 C-M12F08-07X025PU25,0-MA-103782 - Connection cables for read heads CES, CEM, CET with 2 plug connectors M8 and M12
095 005 C-M08F03-02X025PU02,0-M12M04-095005095 357 C-M08F03-02X025PU05,0-M12M04-095357099 167 C-M08F03-02X025PU10,0-M12M04-099167099 168 C-M08F03-02X025PU30,0-M12M04-099168 - Connection cables for the control of the CEM or CET guard locking with 2 plug connectors M8 and M12
100 818 C-M08F04-04X025PV02,0-M12M05100 817 C-M08F04-04X025PV05,0-M12M05
 | Read head CET1-AX-... M12, with guard locking and guard lock monitoring, 2 freely configurable LEDs |
Actuator Bolt Fastening - Mounting plate EMP-L-... for safety switches CET
- Mounting plate EMP-B-... for actuator CET
- Safety screws M5 x 16 for actuator CET-A-BWK-50X
Add-On - Mechanical key release for read head CET
098 850 Mechanical key release - Emergency unlocking for read head CET
103 714 Emergency unlocking CET - Cover for read head and actuator CET
098 808 CET Abdeckung rechts098 807 CET Abdeckung links
Connection material - Connection cables with plug connector M12 for CET...
099 633 C-M12F08-07X025PV10,0-MA-099633099 634 C-M12F08-07X025PV20,0-MA-099634103 115 C-M12F08-07X025PV25,0-MA-103115100 456 C-M12F08-07X025PV10,0-MA-100456105 071 C-M12F08-07X025PV20,0-MA-105071102 218 C-M12F08-07X025PU10,0-MA-102218103 782 C-M12F08-07X025PU25,0-MA-103782 - Connection cables for read heads CES, CEM, CET with 2 plug connectors M8 and M12
095 005 C-M08F03-02X025PU02,0-M12M04-095005095 357 C-M08F03-02X025PU05,0-M12M04-095357099 167 C-M08F03-02X025PU10,0-M12M04-099167099 168 C-M08F03-02X025PU30,0-M12M04-099168 - Connection cables for the control of the CEM or CET guard locking with 2 plug connectors M8 and M12
100 818 C-M08F04-04X025PV02,0-M12M05100 817 C-M08F04-04X025PV05,0-M12M05
 | Read head CET2-AX-... M12, with guard locking and guard lock monitoring |
Actuator Bolt Fastening - Mounting plate EMP-L-... for safety switches CET
- Mounting plate EMP-B-... for actuator CET
- Safety screws M5 x 16 for actuator CET-A-BWK-50X
Add-On - Mechanical key release for read head CET
098 850 Mechanical key release - Emergency unlocking for read head CET
103 714 Emergency unlocking CET - Cover for read head and actuator CET
098 808 CET Abdeckung rechts098 807 CET Abdeckung links
Connection material - Connection cables with plug connector M12 for CET...
099 633 C-M12F08-07X025PV10,0-MA-099633099 634 C-M12F08-07X025PV20,0-MA-099634103 115 C-M12F08-07X025PV25,0-MA-103115100 456 C-M12F08-07X025PV10,0-MA-100456105 071 C-M12F08-07X025PV20,0-MA-105071102 218 C-M12F08-07X025PU10,0-MA-102218103 782 C-M12F08-07X025PU25,0-MA-103782 - Connection cables for read heads CES, CEM, CET with 2 plug connectors M8 and M12
095 005 C-M08F03-02X025PU02,0-M12M04-095005095 357 C-M08F03-02X025PU05,0-M12M04-095357099 167 C-M08F03-02X025PU10,0-M12M04-099167099 168 C-M08F03-02X025PU30,0-M12M04-099168 - Connection cables for the control of the CEM or CET guard locking with 2 plug connectors M8 and M12
100 818 C-M08F04-04X025PV02,0-M12M05100 817 C-M08F04-04X025PV05,0-M12M05
 | Read head CET1-AX-... M12, with guard locking and guard lock monitoring, double insertion slide |
Actuator Fastening - Mounting plate EMP-L-... for safety switches CET
- Mounting plate EMP-B-... for actuator CET
- Safety screws M5 x 16 for actuator CET-A-BWK-50X
Add-On - Mechanical key release for read head CET
098 850 Mechanical key release - Emergency unlocking for read head CET
103 714 Emergency unlocking CET - Cover for read head and actuator CET
098 808 CET Abdeckung rechts098 807 CET Abdeckung links
Connection material - Connection cables with plug connector M12 for CET...
099 633 C-M12F08-07X025PV10,0-MA-099633099 634 C-M12F08-07X025PV20,0-MA-099634103 115 C-M12F08-07X025PV25,0-MA-103115100 456 C-M12F08-07X025PV10,0-MA-100456105 071 C-M12F08-07X025PV20,0-MA-105071102 218 C-M12F08-07X025PU10,0-MA-102218103 782 C-M12F08-07X025PU25,0-MA-103782 - Connection cables for read heads CES, CEM, CET with 2 plug connectors M8 and M12
095 005 C-M08F03-02X025PU02,0-M12M04-095005095 357 C-M08F03-02X025PU05,0-M12M04-095357099 167 C-M08F03-02X025PU10,0-M12M04-099167099 168 C-M08F03-02X025PU30,0-M12M04-099168 - Connection cables for the control of the CEM or CET guard locking with 2 plug connectors M8 and M12
100 818 C-M08F04-04X025PV02,0-M12M05100 817 C-M08F04-04X025PV05,0-M12M05
 | Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release |
Actuator Bolt - Bolt CET-A-C/F with escape release
Fastening - Mounting plate EMP-L-... for safety switches CET
- Mounting plate EMP-B-... for actuator CET
- Safety screws M5 x 16 for actuator CET-A-BWK-50X
Add-On - Mechanical key release for read head CET
098 850 Mechanical key release - Emergency unlocking for read head CET
103 714 Emergency unlocking CET - Cover for read head and actuator CET
098 808 CET Abdeckung rechts098 807 CET Abdeckung links
Connection material - Connection cables with plug connector M12 for CET...
099 633 C-M12F08-07X025PV10,0-MA-099633099 634 C-M12F08-07X025PV20,0-MA-099634103 115 C-M12F08-07X025PV25,0-MA-103115100 456 C-M12F08-07X025PV10,0-MA-100456105 071 C-M12F08-07X025PV20,0-MA-105071102 218 C-M12F08-07X025PU10,0-MA-102218103 782 C-M12F08-07X025PU25,0-MA-103782 - Connection cables for read heads CES, CEM, CET with 2 plug connectors M8 and M12
095 005 C-M08F03-02X025PU02,0-M12M04-095005095 357 C-M08F03-02X025PU05,0-M12M04-095357099 167 C-M08F03-02X025PU10,0-M12M04-099167099 168 C-M08F03-02X025PU30,0-M12M04-099168 - Connection cables for the control of the CEM or CET guard locking with 2 plug connectors M8 and M12
100 818 C-M08F04-04X025PV02,0-M12M05100 817 C-M08F04-04X025PV05,0-M12M05
 | Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release, double insertion slide |
Actuator Fastening - Mounting plate EMP-L-... for safety switches CET
- Mounting plate EMP-B-... for actuator CET
- Safety screws M5 x 16 for actuator CET-A-BWK-50X
Add-On - Mechanical key release for read head CET
098 850 Mechanical key release - Emergency unlocking for read head CET
103 714 Emergency unlocking CET - Cover for read head and actuator CET
098 808 CET Abdeckung rechts098 807 CET Abdeckung links
Connection material - Connection cables with plug connector M12 for CET...
099 633 C-M12F08-07X025PV10,0-MA-099633099 634 C-M12F08-07X025PV20,0-MA-099634103 115 C-M12F08-07X025PV25,0-MA-103115100 456 C-M12F08-07X025PV10,0-MA-100456105 071 C-M12F08-07X025PV20,0-MA-105071102 218 C-M12F08-07X025PU10,0-MA-102218103 782 C-M12F08-07X025PU25,0-MA-103782 - Connection cables for read heads CES, CEM, CET with 2 plug connectors M8 and M12
095 005 C-M08F03-02X025PU02,0-M12M04-095005095 357 C-M08F03-02X025PU05,0-M12M04-095357099 167 C-M08F03-02X025PU10,0-M12M04-099167099 168 C-M08F03-02X025PU30,0-M12M04-099168 - Connection cables for the control of the CEM or CET guard locking with 2 plug connectors M8 and M12
100 818 C-M08F04-04X025PV02,0-M12M05100 817 C-M08F04-04X025PV05,0-M12M05
 | Read head CET1-AX-... M12, with guard locking and guard lock monitoring, escape release and lockout mechanism |
Actuator Bolt - Bolt CET-A-C/F with escape release
Fastening - Mounting plate EMP-L-... for safety switches CET
- Mounting plate EMP-B-... for actuator CET
- Safety screws M5 x 16 for actuator CET-A-BWK-50X
Add-On - Mechanical key release for read head CET
098 850 Mechanical key release - Emergency unlocking for read head CET
103 714 Emergency unlocking CET - Cover for read head and actuator CET
098 808 CET Abdeckung rechts098 807 CET Abdeckung links
Connection material - Connection cables with plug connector M12 for CET...
099 633 C-M12F08-07X025PV10,0-MA-099633099 634 C-M12F08-07X025PV20,0-MA-099634103 115 C-M12F08-07X025PV25,0-MA-103115100 456 C-M12F08-07X025PV10,0-MA-100456105 071 C-M12F08-07X025PV20,0-MA-105071102 218 C-M12F08-07X025PU10,0-MA-102218103 782 C-M12F08-07X025PU25,0-MA-103782 - Connection cables for read heads CES, CEM, CET with 2 plug connectors M8 and M12
095 005 C-M08F03-02X025PU02,0-M12M04-095005095 357 C-M08F03-02X025PU05,0-M12M04-095357099 167 C-M08F03-02X025PU10,0-M12M04-099167099 168 C-M08F03-02X025PU30,0-M12M04-099168 - Connection cables for the control of the CEM or CET guard locking with 2 plug connectors M8 and M12
100 818 C-M08F04-04X025PV02,0-M12M05100 817 C-M08F04-04X025PV05,0-M12M05
 | Read head CET1-AX-... M12, with guard locking and guard lock monitoring and lockout mechanism |
Actuator Bolt - Bolt CET-A-C/F with escape release
Fastening - Mounting plate EMP-L-... for safety switches CET
- Mounting plate EMP-B-... for actuator CET
- Safety screws M5 x 16 for actuator CET-A-BWK-50X
Add-On - Mechanical key release for read head CET
098 850 Mechanical key release - Emergency unlocking for read head CET
103 714 Emergency unlocking CET - Cover for read head and actuator CET
098 808 CET Abdeckung rechts098 807 CET Abdeckung links
Connection material - Connection cables with plug connector M12 for CET...
099 633 C-M12F08-07X025PV10,0-MA-099633099 634 C-M12F08-07X025PV20,0-MA-099634103 115 C-M12F08-07X025PV25,0-MA-103115100 456 C-M12F08-07X025PV10,0-MA-100456105 071 C-M12F08-07X025PV20,0-MA-105071102 218 C-M12F08-07X025PU10,0-MA-102218103 782 C-M12F08-07X025PU25,0-MA-103782 - Connection cables for read heads CES, CEM, CET with 2 plug connectors M8 and M12
095 005 C-M08F03-02X025PU02,0-M12M04-095005095 357 C-M08F03-02X025PU05,0-M12M04-095357099 167 C-M08F03-02X025PU10,0-M12M04-099167099 168 C-M08F03-02X025PU30,0-M12M04-099168 - Connection cables for the control of the CEM or CET guard locking with 2 plug connectors M8 and M12
100 818 C-M08F04-04X025PV02,0-M12M05100 817 C-M08F04-04X025PV05,0-M12M05
 | Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring |
Actuator Bolt Fastening - Mounting plate EMP-L-... for safety switches CET
- Mounting plate EMP-B-... for actuator CET
- Safety screws M5 x 16 for actuator CET-A-BWK-50X
Add-On - Mechanical key release for read head CET
098 850 Mechanical key release - Emergency unlocking for read head CET
103 714 Emergency unlocking CET - Cover for read head and actuator CET
098 808 CET Abdeckung rechts098 807 CET Abdeckung links - Handle for wire front release (Bowden)
Connection material - Connection cables with plug connectors M8 for CES-A-L.../CEM-A-L.../CET-AX straight
077 935 C-M08F03-02X025PV03,0-ES-077935077 793 C-M08F03-02X025PV05,0-ES-077793077 767 C-M08F03-02X025PV10,0-ES-077767077 716 C-M08F03-02X025PV20,0-ES-077716077 717 C-M08F03-02X025PV25,0-ES-077717084 762 C-M08F03-02X025PU05,0-ES-084762084 763 C-M08F03-02X025PU10,0-ES-084763084 764 C-M08F03-02X025PU15,0-ES-084764084 765 C-M08F03-02X025PU20,0-ES-084765084 766 C-M08F03-02X025PU25,0-ES-084766 - Connection cables with plug connectors M8 for CES-A-L.../CEM-A-L.../CET-AX angled
084 701 C-M08F03-02X025PV10,0-ES-084701099 998 C-M08F03-02X025PV25,0-ES-099998098 590 C-M08F03-02X025PU10,0-ES-098590 - Connection cables with plug connector M8 for solenoid operating voltage read head CEM/CET-AX straight
088 813 C-M08F04-04X025PV05,0-ZN-088813088 814 C-M08F04-04X025PV10,0-ZN-088814088 815 C-M08F04-04X025PV15,0-ZN-088815095 035 C-M08F04-04X025PV25,0-ZN-095035097 100 C-M08F04-04X025PV50,0-ZN-097100 - Connection cables with plug connector M8 for solenoid operating voltage read head CEM/CET-AX angled
084 703 C-M08F04-04X025PV10,0-ZN-084703 - Connection cables for read heads CES, CEM, CET with 2 plug connectors M8 and M12
095 005 C-M08F03-02X025PU02,0-M12M04-095005095 357 C-M08F03-02X025PU05,0-M12M04-095357099 167 C-M08F03-02X025PU10,0-M12M04-099167099 168 C-M08F03-02X025PU30,0-M12M04-099168 - Connection cables for the control of the CEM or CET guard locking with 2 plug connectors M8 and M12
100 818 C-M08F04-04X025PV02,0-M12M05100 817 C-M08F04-04X025PV05,0-M12M05
 | Read head CET1-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring, double insertion slide |
Actuator Fastening - Mounting plate EMP-L-... for safety switches CET
- Mounting plate EMP-B-... for actuator CET
- Safety screws M5 x 16 for actuator CET-A-BWK-50X
Add-On - Mechanical key release for read head CET
098 850 Mechanical key release - Emergency unlocking for read head CET
103 714 Emergency unlocking CET - Cover for read head and actuator CET
098 808 CET Abdeckung rechts098 807 CET Abdeckung links - Handle for wire front release (Bowden)
Connection material - Connection cables with plug connectors M8 for CES-A-L.../CEM-A-L.../CET-AX straight
077 935 C-M08F03-02X025PV03,0-ES-077935077 793 C-M08F03-02X025PV05,0-ES-077793077 767 C-M08F03-02X025PV10,0-ES-077767077 716 C-M08F03-02X025PV20,0-ES-077716077 717 C-M08F03-02X025PV25,0-ES-077717084 762 C-M08F03-02X025PU05,0-ES-084762084 763 C-M08F03-02X025PU10,0-ES-084763084 764 C-M08F03-02X025PU15,0-ES-084764084 765 C-M08F03-02X025PU20,0-ES-084765084 766 C-M08F03-02X025PU25,0-ES-084766 - Connection cables with plug connectors M8 for CES-A-L.../CEM-A-L.../CET-AX angled
084 701 C-M08F03-02X025PV10,0-ES-084701099 998 C-M08F03-02X025PV25,0-ES-099998098 590 C-M08F03-02X025PU10,0-ES-098590 - Connection cables with plug connector M8 for solenoid operating voltage read head CEM/CET-AX straight
088 813 C-M08F04-04X025PV05,0-ZN-088813088 814 C-M08F04-04X025PV10,0-ZN-088814088 815 C-M08F04-04X025PV15,0-ZN-088815095 035 C-M08F04-04X025PV25,0-ZN-095035097 100 C-M08F04-04X025PV50,0-ZN-097100 - Connection cables with plug connector M8 for solenoid operating voltage read head CEM/CET-AX angled
084 703 C-M08F04-04X025PV10,0-ZN-084703 - Connection cables for read heads CES, CEM, CET with 2 plug connectors M8 and M12
095 005 C-M08F03-02X025PU02,0-M12M04-095005095 357 C-M08F03-02X025PU05,0-M12M04-095357099 167 C-M08F03-02X025PU10,0-M12M04-099167099 168 C-M08F03-02X025PU30,0-M12M04-099168 - Connection cables for the control of the CEM or CET guard locking with 2 plug connectors M8 and M12
100 818 C-M08F04-04X025PV02,0-M12M05100 817 C-M08F04-04X025PV05,0-M12M05
 | Read head CET2-AX-..., 2 plug connectors M8, with guard locking and guard lock monitoring |
Actuator Bolt Fastening - Mounting plate EMP-L-... for safety switches CET
- Mounting plate EMP-B-... for actuator CET
- Safety screws M5 x 16 for actuator CET-A-BWK-50X
Add-On - Mechanical key release for read head CET
098 850 Mechanical key release - Emergency unlocking for read head CET
103 714 Emergency unlocking CET - Cover for read head and actuator CET
098 808 CET Abdeckung rechts098 807 CET Abdeckung links - Handle for wire front release (Bowden)
Connection material - Connection cables with plug connectors M8 for CES-A-L.../CEM-A-L.../CET-AX straight
077 935 C-M08F03-02X025PV03,0-ES-077935077 793 C-M08F03-02X025PV05,0-ES-077793077 767 C-M08F03-02X025PV10,0-ES-077767077 716 C-M08F03-02X025PV20,0-ES-077716077 717 C-M08F03-02X025PV25,0-ES-077717084 762 C-M08F03-02X025PU05,0-ES-084762084 763 C-M08F03-02X025PU10,0-ES-084763084 764 C-M08F03-02X025PU15,0-ES-084764084 765 C-M08F03-02X025PU20,0-ES-084765084 766 C-M08F03-02X025PU25,0-ES-084766 - Connection cables with plug connectors M8 for CES-A-L.../CEM-A-L.../CET-AX angled
084 701 C-M08F03-02X025PV10,0-ES-084701099 998 C-M08F03-02X025PV25,0-ES-099998098 590 C-M08F03-02X025PU10,0-ES-098590 - Connection cables with plug connector M8 for solenoid operating voltage read head CEM/CET-AX straight
088 813 C-M08F04-04X025PV05,0-ZN-088813088 814 C-M08F04-04X025PV10,0-ZN-088814088 815 C-M08F04-04X025PV15,0-ZN-088815095 035 C-M08F04-04X025PV25,0-ZN-095035097 100 C-M08F04-04X025PV50,0-ZN-097100 - Connection cables with plug connector M8 for solenoid operating voltage read head CEM/CET-AX angled
084 703 C-M08F04-04X025PV10,0-ZN-084703 - Connection cables for read heads CES, CEM, CET with 2 plug connectors M8 and M12
095 005 C-M08F03-02X025PU02,0-M12M04-095005095 357 C-M08F03-02X025PU05,0-M12M04-095357099 167 C-M08F03-02X025PU10,0-M12M04-099167099 168 C-M08F03-02X025PU30,0-M12M04-099168 - Connection cables for the control of the CEM or CET guard locking with 2 plug connectors M8 and M12
100 818 C-M08F04-04X025PV02,0-M12M05100 817 C-M08F04-04X025PV05,0-M12M05
 | Manuals |
| Title | Doc. nr. Edition Date | Languages | Document (Downloads) |
|---|
| Operating Instructions Read Head CET-AX with Guard Locking and Guard Locking Monitoring | 098069 16 11/12 |  | 1508 KB |  | 1501 KB |  | 1512 KB |  | 1554 KB |  | 1508 KB |
 | Catalogs |
| Title | Doc. nr. Edition Date | Languages | Document (Downloads) |
|---|
| Berührungsloses Sicherheitssystem CES | 076609 15 09/11 |  | 25865 KB | | Non-Contact Safety System CES | 076649 15 09/11 |  | 25794 KB | | Système de sécurité sans contact CES | 086818 15 09/11 |  | 25835 KB | | Sistema de seguridad sin contacto CES | 086819 15 09/11 |  | 26530 KB |
 | CAD data |
|
|
|
|
|