- With integrated gateway to the Profibus
- One AS-i master
- Display and buttons for diagnostics and adjustment
- Memory card for different operating modes
- Adjustable time-delay
Gateway to ProfibusFor connection to a Profibus DP as a slave and as a master for an AS-i bus according to specification 3.0. Detection of ground shunt, double addressing and EMC problems. Rapid commissioning with the display without PC. Direct display of faults with plain-text messages. Comprehensive AS-i diagnostics integrated. AS-i configuration software is available. OSSDs (Output Signal Switching Devices)Two OSSDs with two redundant normally closed contacts each InputsOne start input per channel and one feedback loop per channel, also freely selectable. Logic functionsProgrammable with AsiMon software. All safety components can be programmed with different functions as inputs. The inputs can be linked with AND or OR gates or via logic functions such as FlipFlop, switch-on delay, turn-off delay or pulses. Programs can be stored for different operating modes on one memory card. Display and buttonsThe display is used to operate the gateway functionality as well as the monitor at the same time. The diagnostics and maintenance functions are considerably expanded compared to the SFM monitors. They can also be launched on the display without a PC monitor. Incorporated security functions allow the programmed functionality to be protected and monitored. Important: One connection kit must be ordered for each safety monitor Order numbers: |