de-DEen-USfr-FR
Čeština (Česká republika)
Login
HomeSitemapImprint
  • PLe/category 4 for all safety functions
  • Handle, bolt and guard locking in one
  • Integrated PROFINET-RT switch
Multifunctional Gate Box MGB-PN (Profinet)
+more information

Seamless integration by means of bus connection

In the PROFINET version we now also make the wiring easier for you. You define which element is to be integrated and the related function. The MGB supplies the protocol frame with the necessary PROFINET input and output bytes required. Comprehensive diagnostics information in the form of PROFINET messages makes troubleshooting quick and specific. Due the typical ease with which parameters can be set in PROFINET, even the replacement of the system in case of service is a simple matter and can be undertaken in a few minutes.

Interlocking or guard locking? Functions of the versions MGB-L0, MGB-L1 and MGB-L2 compared

Interlocking (MGB-L0, without guard locking)

Together with a handle module, the interlocking module makes it possible to interlock the control of moveable safety guards. The combination also serves as a mechanical door stop at the same time.

The following switch-on condition applies for the safety outputs OA and OB:

  • Safety guard closed (however can be opened at any time)
  • Bolt tongue inserted in the interlocking module

The interlocking module detects the position of the safety guard and the position of the bolt tongue. The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle.

Guard locking (MGB-L1 and MGB-L2)

Together with a handle module, the locking module makes it possible to lock moveable safety guards. The combination also serves as a mechanical door stop at the same time.

The following switch-on condition applies for the safety outputs OA and OB:

  • Safety guard closed
  • Bolt tongue inserted in the locking module
  • Locking arm in locking position (the door cannot be opened)

The locking module detects the position of the safety guard and the position of the bolt tongue. The position of the guard locking is also monitored. The bolt tongue in the handle module is moved into and out of the locking module by actuating the door handle. When the bolt tongue is fully inserted in the locking module, the locking arm locks the bolt tongue in this position. Depending on the version, this locking is by spring force or solenoid force.

  • Version MGB-L1: The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle, mechanically locked).
  • Version MGB-L2: The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle, electrically locked).
+Locking sets MGB-L1...-PN... (guard locking by spring force) with 3 controls or indicators
  • Guard locking with guard lock monitoring in accordance with EN 1088
  • Integrated controls and indicators
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
Locking sets MGB-L1...-PN... (guard locking by spring force) with 3 controls or indicatorsLocking sets MGB-L1...-PN... (guard locking by spring force) with 3 controls or indicatorsLocking sets MGB-L1...-PN... (guard locking by spring force) with 3 controls or indicators

Profinet connection

Connection via plug connector according to IEC 61076- 3-117, type 14 (AIDA standard)

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

Flexible usage as interlocking or guard locking

By means of the corresponding evaluation of the safe device data by the control system, usage can be either as interlocking or guard locking (with or without monitoring).

Order numbers:

  • 110 648 MGB-L1HB-PNA-L-110648
  • 110 649 MGB-L1HB-PNA-R-110649
Dimension drawings
MGB-...-PN...
+Locking sets MGB-L2...-PN... (guard locking by solenoid force) with three controls or indicators
  • Guard locking with guard lock monitoring in accordance with EN 1088
  • Integrated controls and indicators
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
Locking sets MGB-L2...-PN... (guard locking by solenoid force) with three controls or indicatorsLocking sets MGB-L2...-PN... (guard locking by solenoid force) with three controls or indicatorsLocking sets MGB-L2...-PN... (guard locking by solenoid force) with three controls or indicators

Profinet connection

Connection via plug connector according to IEC 61076- 3-117, type 14 (AIDA standard)

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

Flexible usage as interlocking or guard locking

By means of the corresponding evaluation of the safe device data by the control system, usage can be either as interlocking or guard locking (with or without monitoring).

Order numbers:

  • 110 000 MGB-L2HB-PNA-L-110000
  • 110 001 MGB-L2HB-PNA-R-110001
Dimension drawings
MGB-...-PN...

Click on the product to view the available accessories!

+Locking sets MGB-L1...-PN... (guard locking by spring force) with 3 controls or indicators
Add-On
  • Escape release module MGB-E...
    100 465 MGB-E-A-100465
Spare part
  • Evaluation module and bus module MGB-L1...-PN, 2 push buttons and emergency stop
    110 739 MGB-L1B-PNA-R-110739
    110 740 MGB-L1B-PNA-L-110740
  • Handle module MGB-H... with automatically extending lockout mechanism
    111 157 MGB-H-AA1A3-R-111157
    111 158 MGB-H-AA1A3-L-111158
+Locking sets MGB-L2...-PN... (guard locking by solenoid force) with three controls or indicators
Add-On
  • Escape release module MGB-E...
    100 465 MGB-E-A-100465
Spare part
  • Handle module MGB-H... with automatically extending lockout mechanism
    111 157 MGB-H-AA1A3-R-111157
    111 158 MGB-H-AA1A3-L-111158
+Manuals
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Operating Instructions Safety System MGB-L.B-PN.-... (PROFINET)110542
02
11/10
DEENPDF 502 KB
System Manual Safety System MGB-L1B-PNA-.../MGB-L2B-PNA-... (PROFINET) Unicode110543
02
12/10
DEPDF 2294 KB
ENPDF 2251 KB
+Catalogs
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Multifunctional Gate Box MGB106108
04
08/11
DEPDF 26651 KB
Multifunctional Gate Box MGB106109
04
08/11
ENPDF 26595 KB
Multifunctional Gate Box MGB109155
04
08/11
FRPDF 26596 KB
+Declarations of conformity
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Title109337
05
PDF 221 KB
+CAD data
Search
+Search Tips:

Product search:

You can also look for parts of article descriptions. Example: NZ*538* or CES-AR*

Document search:

Search directly with the six-digit order number or document number.