de-DEen-USfr-FRes-ES
Čeština (Česká republika)
Login
HomeSitemapImprint

If your EUCHNER product should be faulty at some point, here you can find the related spare parts.

Spare parts
+more information

Find more information in our product catalog.

+Interlocking module MGB-L0-AR..., without control or indicator
  • Solid door stop
  • LED indicator
  • With cable entry
Interlocking module MGB-L0-AR..., without control or indicator

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 105 331 MGB-L0-AR-AA1A1-M-105331
Interlocking module MGB-L0-AR-...
Without controls
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Interlocking module MGB-L0-ARA..., without control or indicator, RC18
  • Solid door stop
  • LED indicator
  • With plug connector RC18
Interlocking module MGB-L0-ARA..., without control or indicator, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 111 937 MGB-L0-ARA-AA1A1-S1-R-111937
  • 111 941 MGB-L0-ARA-AA1A1-S1-L-111941
Interlocking module MGB-L0-ARA-..., RC18
MGB-...-AR without additional controls and indicators with escape release
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Interlocking module MGB-L0-ARA..., without controls or indicators, RC18
  • Solid door stop
  • LED indicator
  • With plug connector RC18
Interlocking module MGB-L0-ARA..., without controls or indicators, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 110 950 MGB-L0-ARA-AA1A1-S1-R-110950
  • 110 953 MGB-L0-ARA-AA1A1-S1-L-110953
Interlocking module MGB-L0-ARA..., RC18
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Interlocking module MGB-L0-AR..., with 2 push buttons
  • Solid door stop
  • LED indicator
  • 2 pushbuttons (illuminated)
Interlocking module MGB-L0-AR..., with 2 push buttons

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Button

S21 NO contact, white, illuminated
S31 NO contact, blue, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 109 843 MGB-L0-AR-AB5A1-M-109843
Interlocking module MGB-L0-AR-...
With 2 push buttons
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Interlocking module MGB-L0-AR..., 2 push buttons and emergency stop
  • Solid door stop
  • LED indicator
  • Emergency stop according to ISO 13850
  • 2 pushbuttons (illuminated)
Interlocking module MGB-L0-AR..., 2 push buttons and emergency stop

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, yellow, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 106 106 MGB-L0-AR-AA2A1-M-106106
Interlocking module MGB-L0...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
+Interlocking module MGB-L0-AR..., 2 push buttons and emergency stop
  • Solid door stop
  • LED indicator
  • With cable entry
  • Emergency stop according to ISO 13850
  • 2 pushbuttons (illuminated)
Interlocking module MGB-L0-AR..., 2 push buttons and emergency stop

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, yellow, illuminated
S31 NO contact, blue, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 109 001 MGB-L0-AR-AA7A1-M-109001
Interlocking module MGB-L0-AR-...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Interlocking module MGB-L0-ARA..., 2 push buttons and emergency stop, RC18
  • Solid door stop
  • LED indicator
  • With plug connector RC18
  • Emergency stop according to ISO 13850
  • 2 pushbuttons (illuminated)
  • incl. label carrier
Interlocking module MGB-L0-ARA..., 2 push buttons and emergency stop, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

EMERGENCY STOP device

S12 positively driven NC contacts, EMERGENCY stop with turn-to-reset, non-illuminated

Button

S21 NO contact, yellow, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 110 687 MGB-L0-ARA-AA2A1-S1-R-110687
  • 110 688 MGB-L0-ARA-AA2A1-S1-L-110688
Interlocking module MGB-L0-ARA...
With 2 buttons and EMERGENCY STOP device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., without controls or indicators
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
Locking module MGB-L1-AR..., without controls or indicators

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 104 302 MGB-L1-AR-AA1A1-M-104302
Locking module MGB-L1-AR...
Without controls
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-ARA..., without controls or indicators, M12
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With plug connector M12
Locking module MGB-L1-ARA..., without controls or indicators, M12

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 111 521 MGB-L1-ARA-AA1A1-S1-R-111939
  • 111 533 MGB-L1-ARA-AA1A1-S1-L-111943
Locking module MGB-L1-ARA...
Without controls
Dimension drawing
Plug connector M12
(Diagram shows door hinged on the right)
Block diagram
Plug connector M12
+Locking module MGB-L1-ARA..., without controls or indicators, RC18
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With plug connector RC18
Locking module MGB-L1-ARA..., without controls or indicators, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 111 071 MGB-L1-ARA-AA1A1-S1-R-111071
  • 111 074 MGB-L1-ARA-AA1A1-S1-L-111074
Locking module MGB-L1-ARA..., RC18
Without controls
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Locking module MGB-L1-ARA..., without controls or indicators, RC18
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With plug connector RC18
Locking module MGB-L1-ARA..., without controls or indicators, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 111 939 MGB-L1-ARA-AA1A1-S1-R-111939
  • 111 943 MGB-L1-ARA-AA1A1-S1-L-111943
Locking module MGB-L1-ARA...
Without controls
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Locking module MGB-L1-APA.., with 3 push buttons, incl. label carrier, M12 for enabling switch, RC18
  • Solid door stop
  • LED indicator
  • With plug connector R18
  • With plug connector M12 for enabling switch
  • 3 pushbuttons (illuminated)
  • incl. label carrier
Locking module MGB-L1-APA.., with 3 push buttons, incl. label carrier, M12 for enabling switch, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Connection for enabling switch

The devices have an M12 plug connector for the direct connection of an enabling button (e. g. ZSA, order no. 110560).

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Button

S21 NO contact, white, illuminated
S31 NO contact, yellow, illuminated
S41 NO contact, blue, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 114 235 MGB-L1-APA-AA6A1-S5-R-114235
  • 114 237 MGB-L1-APA-AA6A1-S5-L-114237
Dimension drawings
MGB-...-AP with additional controls and indicators, plug connector RC18 and plug connector M12
Plug connector M12
Plug connector RC18
Block diagram and wiring diagram for controls and indicators
Plug connector RC 18
+Locking module MGB-L1-ARA..., 1 push button, IP65
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 1 pushbutton (illuminated)
  • Degree of protection IP65
Locking module MGB-L1-ARA..., 1 push button, IP65

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking type

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Degree of protection IP 65

By using special control and indicators, degree of protection IP 65 is achieved.

Key

S11 NO contact, green, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 110 780 MGB-L1-ARA-AD2A3-M-110780
Locking module MGB-L1-ARA... IP65
With 1 button (illuminated)
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., 1 push button, IP65
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 1 pushbutton (illuminated)
  • Degree of protection IP65
Locking module MGB-L1-AR..., 1 push button, IP65

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking type

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Degree of protection IP 65

By using special control and indicators, degree of protection IP 65 is achieved.

Key

S11 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 974 MGB-L1-AR-AB9A3-M-109974
Locking module MGB-L1-AR... IP65
With 1 button (illuminated)
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., 1 push button, RC18
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With plug connector RC18
  • 1 pushbutton (illuminated)
Locking module MGB-L1-AR..., 1 push button, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking type

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Key

S11 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 887 MGB-L1-AR-AB9A1-S1-R-109887
Locking module MGB-L1-AR...
With 1 button (illuminated)
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Locking module MGB-L1-AR..., 1 push button, RC18
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With plug connector RC18
  • 1 pushbutton (illuminated)
Locking module MGB-L1-AR..., 1 push button, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking type

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Key

S11 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 895 MGB-L1-AR-AB9A1-S1-L-109895
Locking module MGB-L1-AR...
With 1 button (illuminated)
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Locking module MGB-L1-AR..., 1 push button and emergency stop
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • Emergency stop according to ISO 13850 with auxiliary contact
  • 1 pushbutton (illuminated)
Locking module MGB-L1-AR..., 1 push button and emergency stop

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Emergency stop with auxiliary contact

Additional normally open contact in the emergency stop, e.g. as auxiliary contact for the control system.

Button

S21 NO contact, yellow, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 860 MGB-L1-AR-AB7A1-M-109860
Locking module MGB-L1-AR...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
With cable entry
+Locking module MGB-L1-AR..., 2 push buttons
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 2 pushbuttons (illuminated)
Locking module MGB-L1-AR..., 2 push buttons

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Button

S11 NO contact, white illuminated
S21 NO contact, yellow, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 291 MGB-L1-AR-AA9A1-M-109291
Locking module MGB-L1-AR...
With 2 push buttons
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., 2 push buttons incl. label carrier
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 2 pushbuttons (illuminated)
  • incl. label carrier
Locking module MGB-L1-AR..., 2 push buttons incl. label carrier

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Button

S11 NO contact, green illuminated
S21 NO contact, yellow, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 934 MGB-L1-AR-AC2A1-M-109934
Locking module MGB-L1-AR...
With 2 push buttons
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., 2 push buttons
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 2 pushbuttons (illuminated)
Locking module MGB-L1-AR..., 2 push buttons

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Button

S21 NO contact, white illuminated
S31 NO contact, blue, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 752 MGB-L1-AR-AB5A1-M-109752
Locking module MGB-L1-AR...
With 2 push buttons
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., 2 push buttons
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 2 pushbuttons (illuminated)
Locking module MGB-L1-AR..., 2 push buttons

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Button

S21 NO contact, yellow, illuminated
S31 NO contact, blue, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 110 711 MGB-L1-ARA-AC9A1-M-110711
Locking module MGB-L1-AR...
With 2 push buttons
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., 2 push buttons, incl. label carrier
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 2 pushbuttons (illuminated)
  • incl. label carrier
Locking module MGB-L1-AR..., 2 push buttons, incl. label carrier

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Button

S21 NO contact, blue, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 111 434 MGB-L1-ARA-AE3A1-M-111434
  • 111 436 MGB-L1-ARA-AA8A1-S1-R-111436
Locking module MGB-L1-AR...
With 2 push buttons
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., 2 push buttons, incl. label carrier, IP65, RC18
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With plug connector RC18
  • 2 pushbuttons (illuminated)
  • incl. label carrier
Locking module MGB-L1-AR..., 2 push buttons, incl. label carrier, IP65, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Degree of protection IP 65

By using special control and indicators, degree of protection IP 65 is achieved.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Button

S11 NO contact, green, illuminated
S21 NO contact, blue, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 555 MGB-L1-AR-AB3A3-S1-R-109555
  • 109 556 MGB-L1-AR-AB3A3-S1-L-109556
Locking module MGB-L1-AR...
With 2 push buttons
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., 2 push buttons, incl. label carrier, RC18
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With plug connector RC18
  • 2 pushbuttons (illuminated)
  • incl. label carrier
Locking module MGB-L1-AR..., 2 push buttons, incl. label carrier, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Button

S21 NO contact, yellow, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 111 653 MGB-L1-ARA-AA8A1-S1-R-111436
  • 111 654 MGB-L1-ARA-AA8A1-S1-L-111654
Locking module MGB-L1-AR...
With 2 push buttons
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Locking module MGB-L1-AR..., 2 push buttons with emergency stop
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • Emergency stop device
  • 2 pushbuttons (illuminated)
Locking module MGB-L1-AR..., 2 push buttons with emergency stop

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Emergency stop device

S12 positively driven NC contacts, EMERGENCY stop with turn-to-reset, non-illuminated

Button

S21 NO contact, yellow, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 105 328 MGB-L1-AR-AA2A1-M-105328
Locking module MGB-L1-AR...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., 2 push buttons and emergency stop
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • Emergency stop according to ISO 13850 with auxiliary contact
  • 2 pushbuttons (illuminated)
Locking module MGB-L1-AR..., 2 push buttons and emergency stop

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, yellow, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 110 219 MGB-L1-AR-AB8A1-M-110219
Locking module MGB-L1-AR...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-ARA..., 2 push buttons and emergency stop
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • Emergency stop according to ISO 13850
  • 2 pushbuttons (illuminated)
Locking module MGB-L1-ARA..., 2 push buttons and emergency stop

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, green, illuminated
S31 NO contact, blue, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 110 772 MGB-L1-ARA-AD1A1-M-110772
Locking module MGB-L1-ARA...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-ARA..., 2 push buttons and emergency stop
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • Emergency stop according to ISO 13850 with auxiliary contact
  • 2 pushbuttons (illuminated)
Locking module MGB-L1-ARA..., 2 push buttons and emergency stop

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, yellow, illuminated
S31 NO contact, blue, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 110 702 MGB-L1-ARA-AC8A1-M-110702
Locking module MGB-L1-ARA...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-ARA..., 2 push buttons and emergency stop, incl. label carrier
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • Emergency stop according to ISO 13850 with auxiliary contact
  • 2 pushbuttons (illuminated)
  • incl. label carrier
Locking module MGB-L1-ARA..., 2 push buttons and emergency stop, incl. label carrier

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Emergency stop with auxiliary contact

Additional normally open contact in the emergency stop, e.g. as auxiliary contact for the control system.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, blue, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 110 702 MGB-L1-ARA-AC8A1-M-110702
Locking module MGB-L1-ARA...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., 1 push button, selector switch and emergency stop
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 1 pushbutton (illuminated)
  • Selector switch (form V, 90°)
  • Emergency stop according to ISO 13850
Locking module MGB-L1-AR..., 1 push button, selector switch and emergency stop

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Selector switch

Selector switch with 2 positions (form V, 90°). The switch latches in both positions.

Button

S21 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 314 MGB-L1-AR-AB1A1-M-109314
Locking module MGB-L1-AR...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., 1 push button, key-operated switch and emergency stop
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 1 pushbutton (illuminated)
  • Key-operated switch (form V, 40°)
  • Emergency stop according to ISO 13850
Locking module MGB-L1-AR..., 1 push button, key-operated switch and emergency stop

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Key-operated switch form V

  • Form V, 40° angle of rotation with 2 positions. The key latches in position 0. The key can be removed in this position.

Devices with key-operated switch have degree of protection IP42.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 111 263 MGB-L1-ARA-AD7A1-M-111263
Locking module MGB-L1-AR...
With 1 push button, key-operated switch and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-AR..., 2 push buttons and key-operated switch
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 2 pushbuttons (illuminated)
  • Key-operated switch (form L, 90°)
Locking module MGB-L1-AR..., 2 push buttons and key-operated switch

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Key-operated switch form L

  • Form L, 90° angle of rotation with 2 positions. The key latches in both positions, however it can only be removed in position 0.

Devices with key-operated switch have degree of protection IP42.

Button

S21 NO contact, green, illuminated
S31 NO contact, red, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 110 236 MGB-L1-AR-AC5A1-M-110236
Locking module MGB-L1-AR...
With 2 push buttons, key-operated switch
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-ARA..., 2 push buttons and machine stop, incl. label carrier
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • incl. label carrier
  • 2 pushbuttons (illuminated)
  • Machine stop
Locking module MGB-L1-ARA..., 2 push buttons and machine stop, incl. label carrier

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Machine stop

Version as emergency stop but in grey/yellow, e. g. as machine stop. Important: Do not use as emergency stop!

Button

S21 NO contact, white, illuminated
S31 NO contact, green, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 111 253 MGB-L1-ARA-AD8A1-M-111253
  • 111 254 MGB-L1-ARA-AD9A1-M-111254
Locking module MGB-L1-ARA...
With 2 push buttons and machine stop
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-ARA..., 2 push buttons, emergency stop, incl. label carrier, RC18
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With plug connector RC18
  • incl. label carrier
  • 2 pushbuttons (illuminated)
  • Emergency stop according to ISO 13850
Locking module MGB-L1-ARA..., 2 push buttons, emergency stop, incl. label carrier, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, yellow, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 110 685 MGB-L1-ARA-AA2A1-S1-R-110685
  • 110 686 MGB-L1-ARA-AA2A1-S1-L-110686
  • 110 792 MGB-L1-ARA-AA2A1-S1-R-110792
  • 110 793 MGB-L1-ARA-AA2A1-S1-L-110793
Locking module MGB-L1-ARA...
With 2 push buttons and emergency stop device
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Locking module MGB-L1-ARA..., 3 push buttons, incl. label carrier, RC18
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With plug connector RC18
  • incl. label carrier
  • 3 pushbuttons (illuminated)
Locking module MGB-L1-ARA..., 3 push buttons, incl. label carrier, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Button

S11 NO contact, white, illuminated
S21 NO contact, white, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 110 872 MGB-L1-ARA-AD4A1-S1-R-110872
  • 110 873 MGB-L1-ARA-AD4A1-S1-L-110873
Locking module MGB-L1-ARA...
with 3 push buttons
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Locking module MGB-L1-ARA..., 2 push buttons, emergency stop and selector switch
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 2 pushbuttons (illuminated)
  • Selector switch (form V, 90°)
  • Emergency stop according to ISO 13850
Locking module MGB-L1-ARA..., 2 push buttons, emergency stop and selector switch

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L1...The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Selector switch

Selector switch with 2 positions (form V, 90°). The switch latches in both positions.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, red, illuminated
S31 NO contact, green, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 112 913 MGB-L1-ARA-AE9A1-M-112913
  • 112 914 MGB-L1-ARA-AF1A1-M-112914
Locking module MGB-L1-ARA...
With 2 push buttons, emergency stop and selector switch
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L2-AR..., without controls or indicators
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
Locking module MGB-L2-AR..., without controls or indicators

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 104 303 MGB-L2-AR-AA1A1-M-104303
Locking module MGB-L2-AR...
Without controls
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L2-AR..., without controls or indicators, RC18
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With plug connector RC18
Locking module MGB-L2-AR..., without controls or indicators, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 776 MGB-L2-AR-AA1A1-S1-R-109776
  • 109 777 MGB-L2-AR-AA1A1-S1-L-109777
Locking module MGB-L2-AR...
Without controls
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Locking module MGB-L2-AR..., 2 push buttons
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 2 pushbuttons (illuminated)
Locking module MGB-L2-AR..., 2 push buttons

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Button

S11 NO contact, white, illuminated
S21 NO contact, yellow, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 322 MGB-L2-AR-AA9A1-M-109322
Locking module MGB-L2-AR...
With 2 push buttons
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L2-AR..., 2 push buttons
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 2 pushbuttons (illuminated)
Locking module MGB-L2-AR..., 2 push buttons

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Button

S21 NO contact, yellow, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 027 MGB-L2-AR-AA8A1-M-109027
Locking module MGB-L2-AR...
With 2 push buttons
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L2-AR..., 2 push buttons, incl. label carrier
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 2 pushbuttons (illuminated)
  • incl. label carrier
Locking module MGB-L2-AR..., 2 push buttons, incl. label carrier

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Button

S21 NO contact, blue, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 111 438 MGB-L2-ARA-AE3A1-M-111438
  • 111 440 MGB-L2-ARA-AB5A1-M-111440
Locking module MGB-L2-AR...
With 2 push buttons
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L2-AR..., 2 push buttons
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 2 pushbuttons (illuminated)
Locking module MGB-L2-AR..., 2 push buttons

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Button

S21 NO contact, red, illuminated
S31 NO contact, green, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 111 223 MGB-L2-ARA-AD5A1-M-111223
  • 111 226 MGB-L2-ARA-AD6A1-M-111226
Locking module MGB-L2-AR...
With 2 push buttons
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L2-AR..., 2 push buttons and emergency stop
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • Emergency stop according to ISO 13850
  • 2 pushbuttons (illuminated)
Locking module MGB-L2-AR..., 2 push buttons and emergency stop

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, yellow, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 105 797 MGB-L2-AR-AA2A1-M-105797
Locking module MGB-L2-AR...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L2-AR..., 2 push buttons and emergency stop
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • Emergency stop according to ISO 13850 with auxiliary contact
  • 2 pushbuttons (illuminated)
Locking module MGB-L2-AR..., 2 push buttons and emergency stop

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Emergency stop with auxiliary contact

Additional normally open contact in the emergency stop, e.g. as auxiliary contact for the control system.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, yellow, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 880 MGB-L2-AR-AB8A1-M-109880
Locking module MGB-L2-AR...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L2-AR..., 2 push buttons and emergency stop
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • Emergency stop according to ISO 13850 with auxiliary contact
  • 2 pushbuttons (illuminated)
Locking module MGB-L2-AR..., 2 push buttons and emergency stop

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Emergency stop with auxiliary contact

Additional normally open contact in the emergency stop, e.g. as auxiliary contact for the control system.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, green, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 953 MGB-L2-AR-AC3A1-M-109953
Locking module MGB-L2-AR...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L2-AR..., 2 push buttons and emergency stop, incl. label carrier
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • Emergency stop according to ISO 13850 with auxiliary contact
  • 2 pushbuttons (illuminated)
  • incl. label carrier
Locking module MGB-L2-AR..., 2 push buttons and emergency stop, incl. label carrier

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Emergency stop with auxiliary contact

Additional normally open contact in the emergency stop, e.g. as auxiliary contact for the control system.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, blue, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 111 430 MGB-L2-ARA-AE1A1-M-111430
  • 111 432 MGB-L2-ARA-AE2A1-M-111432
Locking module MGB-L2-AR...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L2-AR..., 2 push buttons and emergency stop, incl. label carrier, RC18
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • Plug connector RC18
  • Emergency stop according to ISO 13850
  • 2 pushbuttons (illuminated)
  • incl. label carrier
Locking module MGB-L2-AR..., 2 push buttons and emergency stop, incl. label carrier, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, yellow, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 110 167 MGB-L2-AR-AA2A1-S1-R-110167
  • 110 168 MGB-L2-AR-AA2A1-S1-L-110168
  • 110 708 MGB-L2-ARA-AA2A1-S1-R-110708
  • 110 709 MGB-L2-ARA-AA2A1-S1-L-110709
Locking module MGB-L2-AR...
With 2 push buttons and emergency stop device
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Locking module MGB-L2-ARA..., 3 push buttons and selector switch
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • With cable entry
  • 2 pushbuttons (illuminated)
  • 1 pushbutton (not illuminated)
  • Selector switch (form V, 90°)
Locking module MGB-L2-ARA..., 3 push buttons and selector switch

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Selector switch

Selector switch with 2 positions (form V, 90°). The switch latches in both positions.

Button

S11 NO contact, blue, illuminated
S21 NO contact, yellow, not illuminated
S31 NO contact, red, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 112 310 MGB-L2-ARA-AE6A1-M-112310
  • 112 312 MGB-L2-ARA-AE7A1-M-112312
Locking module MGB-L2-ARA...
With 3 push buttons and selector switch
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L2-ARA..., 4 push buttons, RC18
  • Solid door stop
  • LED indicator
  • Guard locking
  • Mechanical Release
  • Plug connector RC18
  • 4 pushbuttons (illuminated)
Locking module MGB-L2-ARA..., 4 push buttons, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Guard locking types

MGB-L2...The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle).

Mechanical Release

For releasing the guard locking, e.g. in case of a power failure.

Button

S11 NO contact, white, illuminated
S21 NO contact, white, illuminated
S31 NO contact, white, illuminated
S41 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 109 506 MGB-L2-AR-AB2A1-S1-R-109506
  • 109 507 MGB-L2-AR-AB2A1-S1-L-109507
Locking module MGB-L2-ARA...
With 4 push buttons
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Interlocking module MGB-L0-AP.., with 3 push buttons, incl. label carrier, M12 for enabling switch
  • Solid door stop
  • LED indicator
  • With cable entry
  • With plug connector M12 for enabling switch
  • 3 pushbuttons (illuminated)
  • incl. label carrier
Interlocking module MGB-L0-AP.., with 3 push buttons, incl. label carrier, M12 for enabling switch

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Connection for enabling switch

The devices have an M12 plug connector for the direct connection of an enabling button (e. g. ZSA, order no. 110560).

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Button

S21 NO contact, white, illuminated
S31 NO contact, yellow, illuminated
S41 NO contact, blue, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 110 546 MGB-L0-APA-AA6A1-S3-R-110546
  • 110 547 MGB-L0-APA-AA6A1-S3-L-110547
Interlocking module MGB-L0-APA...
with 3 push buttons
Dimension drawing
Plug connector M12
(Diagram shows door hinged on the right)
Block diagram
Cable entry and plug connector M12
+Locking module MGB-L1-APA.., with 2 push buttons, emergency stop, incl. label carrier, RC18
  • Solid door stop
  • LED indicator
  • With plug connector RC18
  • 2 pushbuttons (illuminated)
  • Emergency stop (illuminated)
  • incl. label carrier
Locking module MGB-L1-APA.., with 2 push buttons, emergency stop, incl. label carrier, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Illuminated emergency stop

Emergency stop with illumination that can be controlled as required.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, white, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 109 764 MGB-L1-APA-AB6A1-S1-R-109764
Locking module MGB-L1-APA...
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L1-APA.., with 3 push buttons, incl. label carrier, M12 for enabling switch
  • Solid door stop
  • LED indicator
  • With cable entry
  • With plug connector M12 for enabling switch
  • 3 pushbuttons (illuminated)
  • incl. label carrier
Locking module MGB-L1-APA.., with 3 push buttons, incl. label carrier, M12 for enabling switch

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Connection for enabling switch

The devices have an M12 plug connector for the direct connection of an enabling button (e. g. ZSA, order no. 110560).

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Button

S21 NO contact, white, illuminated
S31 NO contact, yellow, illuminated
S41 NO contact, blue, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 110 585 MGB-L1-APA-AA6A1-S3-R-110585
  • 110 586 MGB-L1-APA-AA6A1-S3-L-110586
Locking module MGB-L1-APA...
with 3 push buttons
Dimension drawing
Plug connector M12
(Diagram shows door hinged on the right)
Block diagram
Cable entry and M12 plug connector
+Locking module MGB-L1-APA.., with 3 push buttons, emergency stop, RC18
  • Solid door stop
  • LED indicator
  • With plug connector RC18
  • 2 pushbuttons (illuminated)
  • 1 pushbutton (not illuminated)
  • Emergency stop according to ISO 13850
Locking module MGB-L1-APA.., with 3 push buttons, emergency stop, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, yellow, illuminated
S31 NO contact, blue, illuminated
S41 NO contact, green, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 111 898 MGB-L1-APA-AE4A1-S1-R-111898
  • 111 903 MGB-L1-APA-AE4A1-S1-L-111903
Locking module MGB-L1-APA...
With 3 push buttons and emergency stop device
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Locking module MGB-L2-APA.., with 2 push buttons, emergency stop, RC18
  • Solid door stop
  • LED indicator
  • With plug connector RC18
  • 2 pushbuttons (illuminated)
  • 1 pushbutton (not illuminated)
  • Illuminated emergency stop
  • incl. label carrier
Locking module MGB-L2-APA.., with 2 push buttons, emergency stop, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Illuminated emergency stop

Emergency stop with illumination that can be controlled as required.

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, white, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 109 765 MGB-L2-APA-AB6A1-S1-R-109765
  • 110 076 MGB-L2-APA-AB6A1-S1-L-110076
Locking module MGB-L2-APA...
With 2 push buttons and emergency stop device
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Locking module MGB-L2-APA.., with 3 push buttons, incl. label carrier, M12
  • Solid door stop
  • LED indicator
  • With cable entry
  • 3 pushbuttons (illuminated)
  • incl. label carrier
Locking module MGB-L2-APA.., with 3 push buttons, incl. label carrier, M12

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Connection for enabling switch

The devices have an M12 plug connector for the direct connection of an enabling button (e. g. ZSA, order no. 110560).

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Button

S21 NO contact, white, illuminated
S31 NO contact, yellow, illuminated
S41 NO contact, blue, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 110 544 MGB-L2-APA-AA6A1-S3-R-110544
  • 110 545 MGB-L2-APA-AA6A1-S3-L-110545
Locking module MGB-L2-APA...
with 3 push buttons
Dimension drawing
(Diagram shows door hinged on the right)
Block diagram
Cable entry
+Locking module MGB-L2-APA.., with 2 push buttons, key-operated switch, incl. label carrier, RC18
  • Solid door stop
  • LED indicator
  • With plug connector RC18
  • 2 pushbuttons (illuminated)
  • Key-operated switch (form L, 90°)
  • Emergency stop according to ISO 13850
  • incl. label carrier
Locking module MGB-L2-APA.., with 2 push buttons, key-operated switch, incl. label carrier, RC18

Door stop

A mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier.

LED indicator

The LED indicator indicates all important system and status information.

Key-operated switch form L

  • Form L, 90° angle of rotation with 2 positions. The key latches in both positions, however it can only be removed in position 0.

Devices with key-operated switch have degree of protection IP42.

Label carrier

Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).

Button

S21 NO contact, yellow, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Not used
O4Diagnostics

Order numbers:

  • 110 523 MGB-L2-APA-AC7A1-S1-R-110523
  • 110 524 MGB-L2-APA-AC7A1-S1-L-110524
Locking module MGB-L2-APA...
With 2 push buttons and key-operated switch
Dimension drawing
Plug connector RC18
(Diagram shows door hinged on the right)
Block diagram
Plug connector RC18
+Evaluation module and bus module MGB-L1...-PN, 2 push buttons and emergency stop
  • Guard locking with guard lock monitoring in accordance with EN 1088
  • Integrated controls and indicators
  • Pre-assembled on mounting plates
  • Mechanical Release
  • Integrated Profinet RT switch
  • Emergency stop according to ISO 13850
  • 2 pushbuttons (illuminated)
Evaluation module and bus module MGB-L1...-PN, 2 push buttons and emergency stop

Profinet connection

Connection via plug connector according to IEC 61076- 3-117, type 14 (AIDA standard)

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

Flexible usage as interlocking or guard locking

By means of the corresponding evaluation of the safe device data by the control system, usage can be either as interlocking or guard locking (with or without monitoring).

Emergency stop device

S12 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated

Button

S21 NO contact, yellow, illuminated
S31 NO contact, white, illuminated

Door monitoring outputs

O1Guard position
O2Bolt position
O3Position of the guard locking
O4Diagnostics

Order numbers:

  • 110 739 MGB-L1B-PNA-R-110739
  • 110 740 MGB-L1B-PNA-L-110740
Evaluation module and bus module MGB-L1...-PN
With 2 push buttons and emergency stop device
Dimension drawing
(Diagram shows door hinged on the right)
+Handle module MGB-H-...
  • Intelligent bolt tongue
  • Lockout bar
  • Door handle
Handle module MGB-H-...

Bolt tongue

The bolt tongue is reliably detected by a transponder as soon as it is inserted in the evaluation module.

Lockout bar

The bolt tongue can be blocked for cleaning and service with max. 3 locks.

Door handle

The MGB has a robust door handle that can be rotated in 90° steps to suit all installations. The actuating direction can be changed for left or right hinged doors.

Door knob

As an alternative to the door handle the handle module can also be equipped with a door knob.

Order numbers:

  • 100 464 MGB-H-AA1A1-R-100464
  • 106 619 MGB-H-AA1A1-L-106619
Handle module MGB-H-...
Dimension drawing
(Diagram shows door hinged on the right)
1
Door handle
2
Locking pins for housing cover and handle adjustment
3
Lockout bar
4
Bolt tongue
+Handle module MGB-H... with automatically extending lockout mechanism
  • Intelligent bolt tongue
  • Fold-out lockout mechanism (as on standard version)
  • Second automatically extending lockout mechanism
  • Door handle
Handle module MGB-H... with automatically extending lockout mechanism

Bolt tongue

The bolt tongue is reliably detected by a transponder as soon as it is inserted in the evaluation module.

Lockout mechanism (automatically extending and fold-out)

For cleaning and service on the machine the bolt tongue can be locked with max. 3 padlocks.

The lockout mechanism extends automatically on the actuation of the handle and prevents the operation of the handle in the safe state. In addition, the fold-out lockout mechanism can be used.

Door handle

The MGB has a robust door handle that can be rotated in 90° steps to suit all installations. The actuating direction can be changed very easily for doors hinged on the left or right.

Door knob

As an alternative to the door handle the handle module can also be equipped with a door knob.

Order numbers:

  • 111 157 MGB-H-AA1A3-R-111157
  • 111 158 MGB-H-AA1A3-L-111158
Handle module MGB-H-...
Dimension drawing
1
Door handle
2
Locking pins for housing cover and handle adjustment
3
Lockout bar
4
Bolt tongue
+Triangular key for safety switch TK

Order numbers:

  • 103 057 Triangular key
+Replacement keys for mechanical key release

Suitable for mechanical key release CET and lock for mechanical release TP/STP

Order numbers:

  • 099 434 Replacement key
Replacement key
Dimension drawing
+Replacement head NZ.VZ

Replacement head for NZ.VZ

(NZ.VZ). With 4 safety screws and replacement screws. As the switches are safety components, in case of defects we recommend replacing the entire safety switch.Not suitable for the safety switches TZ!

Order numbers:

  • 076 250 Actuating head NZVZ
+Lead seal kit TZ and TX

Lead seal kit TZ

For sealing the mechanical release on the safety switch TZ. The locking screw is included.

Lead seal kit TZ-C1937

The lead seal kit TZ-C1937 is also suitable for the emergency unlocking/release on the safety switch TX.

Order numbers:

  • 048 257 Lead seal kit TZ
  • 087 256 Lead seal kit TZ-C1937
Lead seal kit TZ
Dimension drawing
Lead seal kit TZ-C1937
Dimension drawing
+Replacement handle for EUCHNER bolts
  • Material: plastic, reinforced polypropylene (PP)
  • Color: black, mat
  • Temperature resistance up to 100 °C

Order numbers:

  • 093 500 Bolt handle/V5
Replacement handle for EUCHNER bolts
Dimension drawing
+Safety screws M5 x 16 for actuator CET-A-BWK-50X

Safety screws M5 x 16

For actuator CET-A-BWK-50X (replacement) VPE: 100 ea.

Order numbers:

  • 073 456 M5x16/V100
+Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN...

Safety screws M4 x 14

For safety switch CES-AP-C.2... and actuator CES-A-BLN... (replacement) VPE: 100 ea.

Order numbers:

  • 074 063 M4x14/V100
+2-pole jumper for evaluation unit CMS-E-BR/ER

2-pole jumper

For evaluation unit CMS-E-BR/ER, VPE: 10 ea.

Jumper, fully insulated

5.0 or 5.08 mm spacing

Order numbers:

  • 085 665 CMS-A-J2
+3-pole jumper for evaluation unit CMS-E-AR/FR

3-pole jumper

For evaluation unit CMS-E-AR/FR, VPE: 10 ea.

Jumper, fully insulated

5.0 or 5.08 mm spacing

Order numbers:

  • 085 666 CMS-A-J3
+4-pole jumper for evaluation unit CMS-E-AR

4-pole jumper

For evaluation unit CMS-E-AR, VPE: 10 ea.

Jumper, fully insulated

5.0 or 5.08 mm spacing

Order numbers:

  • 085 667 CMS-A-J4

Click on the product to view the available accessories!

+Handle module MGB-H... with automatically extending lockout mechanism
Add-On
  • Door knob for MGB-H...
    111 460 MGB-A-DOORKNOB-111460
+Manuals
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Assembly Instruction Lead Seal Kit TZ/TX047901
02
05/06
DEENFR
ESIT
PDF 105 KB
Safety information and Maintenance Safety System MGB-AR/MGB-AP (from V2.0.0)112656
03
06/12
DEENFR
ESITSV
PDF 1762 KB
PTPDF 414 KB
RUPDF 255 KB
Operating Instructions MGB-L1...AR.-... / MGB-L2...AR.-... and MGB-L1...AP.-... / MGB-L2...AP.-... (from V2.0.0)112659
07
02/13
DEPDF 4163 KB
ENPDF 4143 KB
FRPDF 4132 KB
ESPDF 4136 KB
ITPDF 4160 KB
PTPDF 4210 KB
RUPDF 4151 KB
PLPDF 2654 KB
SVPDF 4123 KB
Operating Instructions MGB-L0...AR.-... and MGB-L0...AP.-... from V2.1.0112657
10
03/13
DEPDF 3145 KB
ENPDF 3114 KB
FRPDF 3104 KB
ESPDF 3107 KB
ITPDF 3122 KB
PTPDF 3145 KB
RUPDF 3370 KB
SVPDF 3097 KB
Safety information and Maintenance MGB-L.B-PN.-... (PROFINET)110542
03
06/12
DEENPDF 541 KB
Operating Instructions Safety System MGB-L..B-PNA-... (PROFINET) with Data Structure Type A114575
02
03/13
DEPDF 2940 KB
ENPDF 2937 KB
FRPDF 2951 KB
ESPDF 2961 KB
PTPDF 2956 KB
+Catalogs
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Berührungsloses Sicherheitssystem CES076609
15
09/11
DEPDF 25865 KB
Sicherheitsschalter mit Kunststoffgehäuse096955
10
10/12
DEPDF 19162 KB
Magnetisch codierte Sicherheitsschalter CMS086823
08
10/12
DEPDF 8125 KB
Sicherheitsschalter mit Metallgehäuse100319
09
01/13
DEPDF 9132 KB
Multifunctional Gate Box MGB106108
05
10/12
DEPDF 25777 KB
Non-Contact Safety System CES076649
15
09/11
ENPDF 25794 KB
Multifunctional Gate Box MGB106109
05
10/12
ENPDF 25628 KB
Safety Switches with Plastic Housing096956
10
10/12
ENPDF 19113 KB
Magnetically Coded Safety Switches CMS086824
08
10/12
ENPDF 8027 KB
Safety Switches with Metal Housing100369
09
01/13
ENPDF 9077 KB
Système de sécurité sans contact CES086818
15
09/11
FRPDF 25835 KB
Multifunctional Gate Box MGB109155
05
10/12
FRPDF 25640 KB
Interrupteurs de sécurité avec boîtier plastique100677
10
10/12
FRPDF 19571 KB
Système de sécurité sans contact CMS090606
08
10/12
FRPDF 8099 KB
Interrupteurs de sécurité avec boîtier métallique100676
09
01/13
FRPDF 9122 KB
Sistema de seguridad sin contacto CES086819
15
09/11
ESPDF 26530 KB
Interruptores de seguridad con carcasa plástica104855
10
10/12
ESPDF 19108 KB
Interruptores de seguridad con carcasa metálica104856
09
01/13
ESPDF 9100 KB
Multifunctional Gate Box MGB114433
05
10/12
ESPDF 25599 KB
Multifunctional Gate Box MGB105887
03
09/11
ITPDF 8127 KB
Safety Switches with Plastic Housing102145
10
10/12
ZHPDF 36379 KB
Safety Switches with Metal Housing102453
09
01/13
ZHPDF 32720 KB
+Declarations of conformity
TitleDoc. nr.
Edition
Date
LanguagesDocument
(Downloads)
Title112654
01
PDF 82 KB
Title105866
07
PDF 90 KB
Title109337
05
PDF 221 KB
+CAD data
Search
+Search Tips:

Product search:

You can also look for parts of article descriptions. Example: NZ*538* or CES-AR*

Document search:

Search directly with the six-digit order number or document number.