 | Interlocking module MGB-L0-AR..., without control or indicator |
- Solid door stop
- LED indicator
- With cable entry
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 105 331 MGB-L0-AR-AA1A1-M-105331
| Interlocking module MGB-L0-AR-... Without controls Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Interlocking module MGB-L0-ARA..., without control or indicator, RC18 |
- Solid door stop
- LED indicator
- With plug connector RC18
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 111 937 MGB-L0-ARA-AA1A1-S1-R-111937
- 111 941 MGB-L0-ARA-AA1A1-S1-L-111941
| Interlocking module MGB-L0-ARA-..., RC18 MGB-...-AR without additional controls and indicators with escape release Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18  |
 | Interlocking module MGB-L0-ARA..., without controls or indicators, RC18 |
- Solid door stop
- LED indicator
- With plug connector RC18
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 110 950 MGB-L0-ARA-AA1A1-S1-R-110950
- 110 953 MGB-L0-ARA-AA1A1-S1-L-110953
| Interlocking module MGB-L0-ARA..., RC18 Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18  |
 | Interlocking module MGB-L0-AR..., with 2 push buttons |
- Solid door stop
- LED indicator
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Button| S2 | 1 NO contact, white, illuminated | | S3 | 1 NO contact, blue, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 109 843 MGB-L0-AR-AB5A1-M-109843
| Interlocking module MGB-L0-AR-... With 2 push buttons Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Interlocking module MGB-L0-AR..., 2 push buttons and emergency stop |
- Solid door stop
- LED indicator
- Emergency stop according to ISO 13850
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 106 106 MGB-L0-AR-AA2A1-M-106106
| Interlocking module MGB-L0... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) |
 | Interlocking module MGB-L0-AR..., 2 push buttons and emergency stop |
- Solid door stop
- LED indicator
- With cable entry
- Emergency stop according to ISO 13850
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, blue, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 109 001 MGB-L0-AR-AA7A1-M-109001
| Interlocking module MGB-L0-AR-... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) |
 | Interlocking module MGB-L0-ARA..., 2 push buttons and emergency stop, RC18 |
- Solid door stop
- LED indicator
- With plug connector RC18
- Emergency stop according to ISO 13850
- 2 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). EMERGENCY STOP device| S1 | 2 positively driven NC contacts, EMERGENCY stop with turn-to-reset, non-illuminated |
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 110 687 MGB-L0-ARA-AA2A1-S1-R-110687
- 110 688 MGB-L0-ARA-AA2A1-S1-L-110688
| Interlocking module MGB-L0-ARA... With 2 buttons and EMERGENCY STOP device Dimension drawing (Diagram shows door hinged on the right) |
 | Locking module MGB-L1-AR..., without controls or indicators |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 104 302 MGB-L1-AR-AA1A1-M-104302
| Locking module MGB-L1-AR... Without controls Dimension drawing (Diagram shows door hinged on the right) |
 | Locking module MGB-L1-ARA..., without controls or indicators, M12 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With plug connector M12
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 111 521 MGB-L1-ARA-AA1A1-S1-R-111939
- 111 533 MGB-L1-ARA-AA1A1-S1-L-111943
| Locking module MGB-L1-ARA... Without controls Dimension drawing Plug connector M12 (Diagram shows door hinged on the right) Block diagram Plug connector M12 |
 | Locking module MGB-L1-ARA..., without controls or indicators, RC18 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With plug connector RC18
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 111 071 MGB-L1-ARA-AA1A1-S1-R-111071
- 111 074 MGB-L1-ARA-AA1A1-S1-L-111074
| Locking module MGB-L1-ARA..., RC18 Without controls Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18  |
 | Locking module MGB-L1-ARA..., without controls or indicators, RC18 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With plug connector RC18
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 111 939 MGB-L1-ARA-AA1A1-S1-R-111939
- 111 943 MGB-L1-ARA-AA1A1-S1-L-111943
| Locking module MGB-L1-ARA... Without controls Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18  |
 | Locking module MGB-L1-APA.., with 3 push buttons, incl. label carrier, M12 for enabling switch, RC18 |
- Solid door stop
- LED indicator
- With plug connector R18
- With plug connector M12 for enabling switch
- 3 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Connection for enabling switchThe devices have an M12 plug connector for the direct connection of an enabling button (e. g. ZSA, order no. 110560). Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Button| S2 | 1 NO contact, white, illuminated | | S3 | 1 NO contact, yellow, illuminated | | S4 | 1 NO contact, blue, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 114 235 MGB-L1-APA-AA6A1-S5-R-114235
- 114 237 MGB-L1-APA-AA6A1-S5-L-114237
| MGB-...-AP with additional controls and indicators, plug connector RC18 and plug connector M12 Plug connector M12 Plug connector RC18 Block diagram and wiring diagram for controls and indicators Plug connector RC 18  |
 | Locking module MGB-L1-ARA..., 1 push button, IP65 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 1 pushbutton (illuminated)
- Degree of protection IP65
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking type| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Degree of protection IP 65By using special control and indicators, degree of protection IP 65 is achieved. Key| S1 | 1 NO contact, green, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 110 780 MGB-L1-ARA-AD2A3-M-110780
| Locking module MGB-L1-ARA... IP65 With 1 button (illuminated) Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-AR..., 1 push button, IP65 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 1 pushbutton (illuminated)
- Degree of protection IP65
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking type| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Degree of protection IP 65By using special control and indicators, degree of protection IP 65 is achieved. Key| S1 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 974 MGB-L1-AR-AB9A3-M-109974
| Locking module MGB-L1-AR... IP65 With 1 button (illuminated) Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-AR..., 1 push button, RC18 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With plug connector RC18
- 1 pushbutton (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking type| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Key| S1 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 887 MGB-L1-AR-AB9A1-S1-R-109887
| Locking module MGB-L1-AR... With 1 button (illuminated) Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18  |
 | Locking module MGB-L1-AR..., 1 push button, RC18 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With plug connector RC18
- 1 pushbutton (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking type| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Key| S1 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 895 MGB-L1-AR-AB9A1-S1-L-109895
| Locking module MGB-L1-AR... With 1 button (illuminated) Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18  |
 | Locking module MGB-L1-AR..., 1 push button and emergency stop |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- Emergency stop according to ISO 13850 with auxiliary contact
- 1 pushbutton (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Emergency stop with auxiliary contactAdditional normally open contact in the emergency stop, e.g. as auxiliary contact for the control system. Button| S2 | 1 NO contact, yellow, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 860 MGB-L1-AR-AB7A1-M-109860
| Locking module MGB-L1-AR... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) Block diagram With cable entry  |
 | Locking module MGB-L1-AR..., 2 push buttons |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Button| S1 | 1 NO contact, white illuminated |
| S2 | 1 NO contact, yellow, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 291 MGB-L1-AR-AA9A1-M-109291
| Locking module MGB-L1-AR... With 2 push buttons Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-AR..., 2 push buttons incl. label carrier |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 2 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Button| S1 | 1 NO contact, green illuminated |
| S2 | 1 NO contact, yellow, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 934 MGB-L1-AR-AC2A1-M-109934
| Locking module MGB-L1-AR... With 2 push buttons Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-AR..., 2 push buttons |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Button| S2 | 1 NO contact, white illuminated |
| S3 | 1 NO contact, blue, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 752 MGB-L1-AR-AB5A1-M-109752
| Locking module MGB-L1-AR... With 2 push buttons Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-AR..., 2 push buttons |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Button| S2 | 1 NO contact, yellow, illuminated |
| S3 | 1 NO contact, blue, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 110 711 MGB-L1-ARA-AC9A1-M-110711
| Locking module MGB-L1-AR... With 2 push buttons Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-AR..., 2 push buttons, incl. label carrier |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 2 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Button| S2 | 1 NO contact, blue, illuminated |
| S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 111 434 MGB-L1-ARA-AE3A1-M-111434
- 111 436 MGB-L1-ARA-AA8A1-S1-R-111436
| Locking module MGB-L1-AR... With 2 push buttons Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry |
 | Locking module MGB-L1-AR..., 2 push buttons, incl. label carrier, IP65, RC18 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With plug connector RC18
- 2 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Degree of protection IP 65By using special control and indicators, degree of protection IP 65 is achieved. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Button| S1 | 1 NO contact, green, illuminated |
| S2 | 1 NO contact, blue, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 555 MGB-L1-AR-AB3A3-S1-R-109555
- 109 556 MGB-L1-AR-AB3A3-S1-L-109556
| Locking module MGB-L1-AR... With 2 push buttons Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry |
 | Locking module MGB-L1-AR..., 2 push buttons, incl. label carrier, RC18 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With plug connector RC18
- 2 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Button| S2 | 1 NO contact, yellow, illuminated |
| S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 111 653 MGB-L1-ARA-AA8A1-S1-R-111436
- 111 654 MGB-L1-ARA-AA8A1-S1-L-111654
| Locking module MGB-L1-AR... With 2 push buttons Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18  |
 | Locking module MGB-L1-AR..., 2 push buttons with emergency stop |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- Emergency stop device
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Emergency stop device| S1 | 2 positively driven NC contacts, EMERGENCY stop with turn-to-reset, non-illuminated |
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 105 328 MGB-L1-AR-AA2A1-M-105328
| Locking module MGB-L1-AR... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-AR..., 2 push buttons and emergency stop |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- Emergency stop according to ISO 13850 with auxiliary contact
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 110 219 MGB-L1-AR-AB8A1-M-110219
| Locking module MGB-L1-AR... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-ARA..., 2 push buttons and emergency stop |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- Emergency stop according to ISO 13850
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, green, illuminated | | S3 | 1 NO contact, blue, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 110 772 MGB-L1-ARA-AD1A1-M-110772
| Locking module MGB-L1-ARA... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-ARA..., 2 push buttons and emergency stop |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- Emergency stop according to ISO 13850 with auxiliary contact
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, blue, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 110 702 MGB-L1-ARA-AC8A1-M-110702
| Locking module MGB-L1-ARA... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-ARA..., 2 push buttons and emergency stop, incl. label carrier |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- Emergency stop according to ISO 13850 with auxiliary contact
- 2 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Emergency stop with auxiliary contactAdditional normally open contact in the emergency stop, e.g. as auxiliary contact for the control system. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, blue, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 110 702 MGB-L1-ARA-AC8A1-M-110702
| Locking module MGB-L1-ARA... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-AR..., 1 push button, selector switch and emergency stop |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 1 pushbutton (illuminated)
- Selector switch (form V, 90°)
- Emergency stop according to ISO 13850
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Selector switchSelector switch with 2 positions (form V, 90°). The switch latches in both positions. Button| S2 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 314 MGB-L1-AR-AB1A1-M-109314
| Locking module MGB-L1-AR... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-AR..., 1 push button, key-operated switch and emergency stop |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 1 pushbutton (illuminated)
- Key-operated switch (form V, 40°)
- Emergency stop according to ISO 13850
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Key-operated switch form V- Form V, 40° angle of rotation with 2 positions. The key latches in position 0. The key can be removed in this position.
Devices with key-operated switch have degree of protection IP42. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 111 263 MGB-L1-ARA-AD7A1-M-111263
| Locking module MGB-L1-AR... With 1 push button, key-operated switch and emergency stop device Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-AR..., 2 push buttons and key-operated switch |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 2 pushbuttons (illuminated)
- Key-operated switch (form L, 90°)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Key-operated switch form L- Form L, 90° angle of rotation with 2 positions. The key latches in both positions, however it can only be removed in position 0.
Devices with key-operated switch have degree of protection IP42. Button| S2 | 1 NO contact, green, illuminated | | S3 | 1 NO contact, red, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 110 236 MGB-L1-AR-AC5A1-M-110236
| Locking module MGB-L1-AR... With 2 push buttons, key-operated switch Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-ARA..., 2 push buttons and machine stop, incl. label carrier |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- incl. label carrier
- 2 pushbuttons (illuminated)
- Machine stop
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Machine stopVersion as emergency stop but in grey/yellow, e. g. as machine stop. Important: Do not use as emergency stop! Button| S2 | 1 NO contact, white, illuminated | | S3 | 1 NO contact, green, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 111 253 MGB-L1-ARA-AD8A1-M-111253
- 111 254 MGB-L1-ARA-AD9A1-M-111254
| Locking module MGB-L1-ARA... With 2 push buttons and machine stop Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L1-ARA..., 2 push buttons, emergency stop, incl. label carrier, RC18 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With plug connector RC18
- incl. label carrier
- 2 pushbuttons (illuminated)
- Emergency stop according to ISO 13850
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 110 685 MGB-L1-ARA-AA2A1-S1-R-110685
- 110 686 MGB-L1-ARA-AA2A1-S1-L-110686
- 110 792 MGB-L1-ARA-AA2A1-S1-R-110792
- 110 793 MGB-L1-ARA-AA2A1-S1-L-110793
| Locking module MGB-L1-ARA... With 2 push buttons and emergency stop device Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18  |
 | Locking module MGB-L1-ARA..., 3 push buttons, incl. label carrier, RC18 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With plug connector RC18
- incl. label carrier
- 3 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Button| S1 | 1 NO contact, white, illuminated | | S2 | 1 NO contact, white, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 110 872 MGB-L1-ARA-AD4A1-S1-R-110872
- 110 873 MGB-L1-ARA-AD4A1-S1-L-110873
| Locking module MGB-L1-ARA... with 3 push buttons Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18  |
 | Locking module MGB-L1-ARA..., 2 push buttons, emergency stop and selector switch |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 2 pushbuttons (illuminated)
- Selector switch (form V, 90°)
- Emergency stop according to ISO 13850
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L1... | The locking arm is kept in locked position by spring force and is unlocked by solenoid force (closed-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Selector switchSelector switch with 2 positions (form V, 90°). The switch latches in both positions. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, red, illuminated | | S3 | 1 NO contact, green, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 112 913 MGB-L1-ARA-AE9A1-M-112913
- 112 914 MGB-L1-ARA-AF1A1-M-112914
| Locking module MGB-L1-ARA... With 2 push buttons, emergency stop and selector switch Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L2-AR..., without controls or indicators |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 104 303 MGB-L2-AR-AA1A1-M-104303
| Locking module MGB-L2-AR... Without controls Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L2-AR..., without controls or indicators, RC18 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With plug connector RC18
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 776 MGB-L2-AR-AA1A1-S1-R-109776
- 109 777 MGB-L2-AR-AA1A1-S1-L-109777
| Locking module MGB-L2-AR... Without controls Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18  |
 | Locking module MGB-L2-AR..., 2 push buttons |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Button| S1 | 1 NO contact, white, illuminated | | S2 | 1 NO contact, yellow, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 322 MGB-L2-AR-AA9A1-M-109322
| Locking module MGB-L2-AR... With 2 push buttons Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L2-AR..., 2 push buttons |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 027 MGB-L2-AR-AA8A1-M-109027
| Locking module MGB-L2-AR... With 2 push buttons Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L2-AR..., 2 push buttons, incl. label carrier |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 2 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Button| S2 | 1 NO contact, blue, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 111 438 MGB-L2-ARA-AE3A1-M-111438
- 111 440 MGB-L2-ARA-AB5A1-M-111440
| Locking module MGB-L2-AR... With 2 push buttons Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L2-AR..., 2 push buttons |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Button| S2 | 1 NO contact, red, illuminated | | S3 | 1 NO contact, green, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 111 223 MGB-L2-ARA-AD5A1-M-111223
- 111 226 MGB-L2-ARA-AD6A1-M-111226
| Locking module MGB-L2-AR... With 2 push buttons Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L2-AR..., 2 push buttons and emergency stop |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- Emergency stop according to ISO 13850
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 105 797 MGB-L2-AR-AA2A1-M-105797
| Locking module MGB-L2-AR... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) |
 | Locking module MGB-L2-AR..., 2 push buttons and emergency stop |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- Emergency stop according to ISO 13850 with auxiliary contact
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Emergency stop with auxiliary contactAdditional normally open contact in the emergency stop, e.g. as auxiliary contact for the control system. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 880 MGB-L2-AR-AB8A1-M-109880
| Locking module MGB-L2-AR... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) |
 | Locking module MGB-L2-AR..., 2 push buttons and emergency stop |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- Emergency stop according to ISO 13850 with auxiliary contact
- 2 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Emergency stop with auxiliary contactAdditional normally open contact in the emergency stop, e.g. as auxiliary contact for the control system. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, green, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 953 MGB-L2-AR-AC3A1-M-109953
| Locking module MGB-L2-AR... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) |
 | Locking module MGB-L2-AR..., 2 push buttons and emergency stop, incl. label carrier |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- Emergency stop according to ISO 13850 with auxiliary contact
- 2 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Emergency stop with auxiliary contactAdditional normally open contact in the emergency stop, e.g. as auxiliary contact for the control system. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, blue, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 111 430 MGB-L2-ARA-AE1A1-M-111430
- 111 432 MGB-L2-ARA-AE2A1-M-111432
| Locking module MGB-L2-AR... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) |
 | Locking module MGB-L2-AR..., 2 push buttons and emergency stop, incl. label carrier, RC18 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- Plug connector RC18
- Emergency stop according to ISO 13850
- 2 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 110 167 MGB-L2-AR-AA2A1-S1-R-110167
- 110 168 MGB-L2-AR-AA2A1-S1-L-110168
- 110 708 MGB-L2-ARA-AA2A1-S1-R-110708
- 110 709 MGB-L2-ARA-AA2A1-S1-L-110709
| Locking module MGB-L2-AR... With 2 push buttons and emergency stop device Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18 |
 | Locking module MGB-L2-ARA..., 3 push buttons and selector switch |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- With cable entry
- 2 pushbuttons (illuminated)
- 1 pushbutton (not illuminated)
- Selector switch (form V, 90°)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Selector switchSelector switch with 2 positions (form V, 90°). The switch latches in both positions. Button| S1 | 1 NO contact, blue, illuminated | | S2 | 1 NO contact, yellow, not illuminated | | S3 | 1 NO contact, red, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 112 310 MGB-L2-ARA-AE6A1-M-112310
- 112 312 MGB-L2-ARA-AE7A1-M-112312
| Locking module MGB-L2-ARA... With 3 push buttons and selector switch Dimension drawing (Diagram shows door hinged on the right) Block diagram Cable entry  |
 | Locking module MGB-L2-ARA..., 4 push buttons, RC18 |
- Solid door stop
- LED indicator
- Guard locking
- Mechanical Release
- Plug connector RC18
- 4 pushbuttons (illuminated)
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Guard locking types| MGB-L2... | The locking arm is kept in locked position by solenoid force and unlocked by spring force when the solenoid is switched off (open-circuit current principle). |
Mechanical ReleaseFor releasing the guard locking, e.g. in case of a power failure. Button| S1 | 1 NO contact, white, illuminated | | S2 | 1 NO contact, white, illuminated | | S3 | 1 NO contact, white, illuminated | | S4 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 109 506 MGB-L2-AR-AB2A1-S1-R-109506
- 109 507 MGB-L2-AR-AB2A1-S1-L-109507
| Locking module MGB-L2-ARA... With 4 push buttons Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18  |
 | Interlocking module MGB-L0-AP.., with 3 push buttons, incl. label carrier, M12 for enabling switch |
- Solid door stop
- LED indicator
- With cable entry
- With plug connector M12 for enabling switch
- 3 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Connection for enabling switchThe devices have an M12 plug connector for the direct connection of an enabling button (e. g. ZSA, order no. 110560). Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Button| S2 | 1 NO contact, white, illuminated | | S3 | 1 NO contact, yellow, illuminated | | S4 | 1 NO contact, blue, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 110 546 MGB-L0-APA-AA6A1-S3-R-110546
- 110 547 MGB-L0-APA-AA6A1-S3-L-110547
| Interlocking module MGB-L0-APA... with 3 push buttons Dimension drawing Plug connector M12 (Diagram shows door hinged on the right) Block diagram Cable entry and plug connector M12 |
 | Locking module MGB-L1-APA.., with 2 push buttons, emergency stop, incl. label carrier, RC18 |
- Solid door stop
- LED indicator
- With plug connector RC18
- 2 pushbuttons (illuminated)
- Emergency stop (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L1... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Illuminated emergency stopEmergency stop with illumination that can be controlled as required. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, white, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 109 764 MGB-L1-APA-AB6A1-S1-R-109764
| Locking module MGB-L1-APA... With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) |
 | Locking module MGB-L1-APA.., with 3 push buttons, incl. label carrier, M12 for enabling switch |
- Solid door stop
- LED indicator
- With cable entry
- With plug connector M12 for enabling switch
- 3 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Connection for enabling switchThe devices have an M12 plug connector for the direct connection of an enabling button (e. g. ZSA, order no. 110560). Label carrierDevices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm). Button| S2 | 1 NO contact, white, illuminated | | S3 | 1 NO contact, yellow, illuminated | | S4 | 1 NO contact, blue, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 110 585 MGB-L1-APA-AA6A1-S3-R-110585
- 110 586 MGB-L1-APA-AA6A1-S3-L-110586
| Locking module MGB-L1-APA... with 3 push buttons Dimension drawing Plug connector M12 (Diagram shows door hinged on the right) Block diagram Cable entry and M12 plug connector |
 | Locking module MGB-L1-APA.., with 3 push buttons, emergency stop, RC18 |
- Solid door stop
- LED indicator
- With plug connector RC18
- 2 pushbuttons (illuminated)
- 1 pushbutton (not illuminated)
- Emergency stop according to ISO 13850
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L0... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, blue, illuminated | | S4 | 1 NO contact, green, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 111 898 MGB-L1-APA-AE4A1-S1-R-111898
- 111 903 MGB-L1-APA-AE4A1-S1-L-111903
| Locking module MGB-L1-APA... With 3 push buttons and emergency stop device Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18 |
 | Locking module MGB-L2-APA.., with 2 push buttons, emergency stop, RC18 |
- Solid door stop
- LED indicator
- With plug connector RC18
- 2 pushbuttons (illuminated)
- 1 pushbutton (not illuminated)
- Illuminated emergency stop
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Label carrier
Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).
Illuminated emergency stopEmergency stop with illumination that can be controlled as required. Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, white, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 109 765 MGB-L2-APA-AB6A1-S1-R-109765
- 110 076 MGB-L2-APA-AB6A1-S1-L-110076
| Locking module MGB-L2-APA... With 2 push buttons and emergency stop device Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18 |
 | Locking module MGB-L2-APA.., with 3 push buttons, incl. label carrier, M12 |
- Solid door stop
- LED indicator
- With cable entry
- 3 pushbuttons (illuminated)
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Connection for enabling switchThe devices have an M12 plug connector for the direct connection of an enabling button (e. g. ZSA, order no. 110560). Label carrier
Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).
Button| S2 | 1 NO contact, white, illuminated | | S3 | 1 NO contact, yellow, illuminated | | S4 | 1 NO contact, blue, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 110 544 MGB-L2-APA-AA6A1-S3-R-110544
- 110 545 MGB-L2-APA-AA6A1-S3-L-110545
| Locking module MGB-L2-APA... with 3 push buttons Dimension drawing (Diagram shows door hinged on the right) |
 | Locking module MGB-L2-APA.., with 2 push buttons, key-operated switch, incl. label carrier, RC18 |
- Solid door stop
- LED indicator
- With plug connector RC18
- 2 pushbuttons (illuminated)
- Key-operated switch (form L, 90°)
- Emergency stop according to ISO 13850
- incl. label carrier
Door stopA mechanical door stop is permanently integrated into the evaluation module MGB-L2... A marking on the stop makes adjustment easier. LED indicatorThe LED indicator indicates all important system and status information. Key-operated switch form L- Form L, 90° angle of rotation with 2 positions. The key latches in both positions, however it can only be removed in position 0.
Devices with key-operated switch have degree of protection IP42. Label carrier
Devices with label carrier have pre-formed recesses. The label carrier enclosed can be bonded in this recess (standard dimension 12.5 x 27 mm).
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Not used | | O4 | Diagnostics |
Order numbers:- 110 523 MGB-L2-APA-AC7A1-S1-R-110523
- 110 524 MGB-L2-APA-AC7A1-S1-L-110524
| Locking module MGB-L2-APA... With 2 push buttons and key-operated switch Dimension drawing Plug connector RC18 (Diagram shows door hinged on the right) Block diagram Plug connector RC18 |
 | Evaluation module and bus module MGB-L1...-PN, 2 push buttons and emergency stop |
- Guard locking with guard lock monitoring in accordance with EN 1088
- Integrated controls and indicators
- Pre-assembled on mounting plates
- Mechanical Release
- Integrated Profinet RT switch
- Emergency stop according to ISO 13850
- 2 pushbuttons (illuminated)
Profinet connectionConnection via plug connector according to IEC 61076- 3-117, type 14 (AIDA standard) Profinet RT switchPoint-to-point topology network structure due to integrated RT switch. Flexible usage as interlocking or guard lockingBy means of the corresponding evaluation of the safe device data by the control system, usage can be either as interlocking or guard locking (with or without monitoring). Emergency stop device| S1 | 2 positively driven NC contacts, emergency stop with turn-to-reset, not illuminated |
Button| S2 | 1 NO contact, yellow, illuminated | | S3 | 1 NO contact, white, illuminated |
Door monitoring outputs| O1 | Guard position | | O2 | Bolt position | | O3 | Position of the guard locking | | O4 | Diagnostics |
Order numbers:- 110 739 MGB-L1B-PNA-R-110739
- 110 740 MGB-L1B-PNA-L-110740
| Evaluation module and bus module MGB-L1...-PN With 2 push buttons and emergency stop device Dimension drawing (Diagram shows door hinged on the right) |
 | Handle module MGB-H-... |
- Intelligent bolt tongue
- Lockout bar
- Door handle
Bolt tongueThe bolt tongue is reliably detected by a transponder as soon as it is inserted in the evaluation module. Lockout barThe bolt tongue can be blocked for cleaning and service with max. 3 locks. Door handleThe MGB has a robust door handle that can be rotated in 90° steps to suit all installations. The actuating direction can be changed for left or right hinged doors. Door knobAs an alternative to the door handle the handle module can also be equipped with a door knob. Order numbers:- 100 464 MGB-H-AA1A1-R-100464
- 106 619 MGB-H-AA1A1-L-106619
| Dimension drawing (Diagram shows door hinged on the right) | 1 | Door handle | | 2 | Locking pins for housing cover and handle adjustment | | 3 | Lockout bar | | 4 | Bolt tongue |
|
 | Handle module MGB-H... with automatically extending lockout mechanism |
- Intelligent bolt tongue
- Fold-out lockout mechanism (as on standard version)
- Second automatically extending lockout mechanism
- Door handle
Bolt tongueThe bolt tongue is reliably detected by a transponder as soon as it is inserted in the evaluation module. Lockout mechanism (automatically extending and fold-out)For cleaning and service on the machine the bolt tongue can be locked with max. 3 padlocks. The lockout mechanism extends automatically on the actuation of the handle and prevents the operation of the handle in the safe state. In addition, the fold-out lockout mechanism can be used. Door handleThe MGB has a robust door handle that can be rotated in 90° steps to suit all installations. The actuating direction can be changed very easily for doors hinged on the left or right. Door knobAs an alternative to the door handle the handle module can also be equipped with a door knob. Order numbers:- 111 157 MGB-H-AA1A3-R-111157
- 111 158 MGB-H-AA1A3-L-111158
| Dimension drawing | 1 | Door handle | | 2 | Locking pins for housing cover and handle adjustment | | 3 | Lockout bar | | 4 | Bolt tongue |
|
 | Triangular key for safety switch TK |
 | Replacement keys for mechanical key release |
|
Suitable for mechanical key release CET and lock for mechanical release TP/STP
Order numbers: | |
 | Replacement head NZ.VZ |
Replacement head for NZ.VZ(NZ.VZ). With 4 safety screws and replacement screws. As the switches are safety components, in case of defects we recommend replacing the entire safety switch.Not suitable for the safety switches TZ! Order numbers:- 076 250 Actuating head NZVZ
| |
 | Lead seal kit TZ and TX |
Lead seal kit TZFor sealing the mechanical release on the safety switch TZ. The locking screw is included. Lead seal kit TZ-C1937The lead seal kit TZ-C1937 is also suitable for the emergency unlocking/release on the safety switch TX. Order numbers:- 048 257 Lead seal kit TZ
- 087 256 Lead seal kit TZ-C1937
| |
 | Replacement handle for EUCHNER bolts |
- Material: plastic, reinforced polypropylene (PP)
- Color: black, mat
- Temperature resistance up to 100 °C
Order numbers: | Replacement handle for EUCHNER bolts |
 | Safety screws M5 x 16 for actuator CET-A-BWK-50X |
Safety screws M5 x 16For actuator CET-A-BWK-50X (replacement) VPE: 100 ea. Order numbers: | |
 | Safety screws M4 x 14 for safety switch CES-AP-C.2... and actuator CES-A-BLN... |
Safety screws M4 x 14For safety switch CES-AP-C.2... and actuator CES-A-BLN... (replacement) VPE: 100 ea. Order numbers: | |
 | 2-pole jumper for evaluation unit CMS-E-BR/ER |
2-pole jumperFor evaluation unit CMS-E-BR/ER, VPE: 10 ea. Jumper, fully insulated 5.0 or 5.08 mm spacing Order numbers: | |
 | 3-pole jumper for evaluation unit CMS-E-AR/FR |
3-pole jumperFor evaluation unit CMS-E-AR/FR, VPE: 10 ea. Jumper, fully insulated 5.0 or 5.08 mm spacing Order numbers: | |
 | 4-pole jumper for evaluation unit CMS-E-AR |
4-pole jumperFor evaluation unit CMS-E-AR, VPE: 10 ea. Jumper, fully insulated 5.0 or 5.08 mm spacing Order numbers: | |
Click on the product to view the available accessories!  | Handle module MGB-H... with automatically extending lockout mechanism |
Add-On - Door knob for MGB-H...
111 460 MGB-A-DOORKNOB-111460
 | Manuals |
 | Catalogs |
| Title | Doc. nr. Edition Date | Languages | Document (Downloads) |
|---|
| Berührungsloses Sicherheitssystem CES | 076609 15 09/11 |  | 25865 KB | | Sicherheitsschalter mit Kunststoffgehäuse | 096955 10 10/12 |  | 19162 KB | | Magnetisch codierte Sicherheitsschalter CMS | 086823 08 10/12 |  | 8125 KB | | Sicherheitsschalter mit Metallgehäuse | 100319 09 01/13 |  | 9132 KB | | Multifunctional Gate Box MGB | 106108 05 10/12 |  | 25777 KB | | Non-Contact Safety System CES | 076649 15 09/11 |  | 25794 KB | | Multifunctional Gate Box MGB | 106109 05 10/12 |  | 25628 KB | | Safety Switches with Plastic Housing | 096956 10 10/12 |  | 19113 KB | | Magnetically Coded Safety Switches CMS | 086824 08 10/12 |  | 8027 KB | | Safety Switches with Metal Housing | 100369 09 01/13 |  | 9077 KB | | Système de sécurité sans contact CES | 086818 15 09/11 |  | 25835 KB | | Multifunctional Gate Box MGB | 109155 05 10/12 |  | 25640 KB | | Interrupteurs de sécurité avec boîtier plastique | 100677 10 10/12 |  | 19571 KB | | Système de sécurité sans contact CMS | 090606 08 10/12 |  | 8099 KB | | Interrupteurs de sécurité avec boîtier métallique | 100676 09 01/13 |  | 9122 KB | | Sistema de seguridad sin contacto CES | 086819 15 09/11 |  | 26530 KB | | Interruptores de seguridad con carcasa plástica | 104855 10 10/12 |  | 19108 KB | | Interruptores de seguridad con carcasa metálica | 104856 09 01/13 |  | 9100 KB | | Multifunctional Gate Box MGB | 114433 05 10/12 |  | 25599 KB | | Multifunctional Gate Box MGB | 105887 03 09/11 |  | 8127 KB | | Safety Switches with Plastic Housing | 102145 10 10/12 |  | 36379 KB | | Safety Switches with Metal Housing | 102453 09 01/13 |  | 32720 KB |
 | CAD data |
|
|
|
|
|