NEWS 2017

More than simply safeguarding – the new MGB2 Modular

A revised design, new and expanded functions as well as a modular layout – the new MGB2 Modular  is more than a simple safeguard device. Thanks to the modular design, the MGB2 Modular can be flexibly adapted to the specific application requirements of the safeguarded door. Designed to accept two configurable sub-modules, up to six control operators can be integrated into the base locking module. Sub-module replacement is possible at any time, as the MGB2 is hotpluggable. In tight spaces, the compact bus module (MBM) with integrated Profinet/Profisafe can be conveniently mounted remotely. Using MBM, connection of two MGB2 Modular systems is also possible, creating a very flexible solution.

more information

 

Integrated controls – the new CTP-Extended

With the new CTP-Extended, it is possible to integrate up to three control and indicator elements into the switch cover. These make it possible to initiate control signals, for example emergency stop, request to enter, and reset functionality, directly at the switch. In combination with a bolt system, the CTP-Extended represents a complete solution for safeguarded doors, including door handle and end stop.

more information

 

 

No chance of getting locked-in – the new CTP-BI

The new CTP-BI has a Bi-stable locking function. When the operating voltage is switched off, the guard locking is maintained in its current position. This means that the safeguarded door remains either locked or unlocked, regardless of locking principle, until power is reapplied. The Bi-stable guardlocking solenoid therefore provides an additional measure of prevention of an individual becoming accidentally locked inside a guardlocked door, whether for service, maintenance, or cleaning.

more information

 

 

For usage in potentially explosive atmospheres – the new CTP-EX

The transponder-coded safety switch CTP with guard locking has been expanded with a variant for usage in potentially explosive atmospheres. In the version CTP-EX, the safety switch can be used in zone 2 (gas environment) and zone 22 (dust environment).

more information

 

 

 

For operation as a standalone device – CEM-C40 with M12 plug connector

The new transponder-coded safety switch CEM-C40 with solenoid and integrated evaluation electronics is available from now on with M12 plug connector for simple connection to decentralized peripheral devices as well as for operation as a standalone device.

  more information



Documents to download