EUCHNER – More than safety.
EUCHNER – More than safety.

CIT3ASX1R1G05KX (Order no. 077890)

Read/write head CIT3A G05 with serial interface

CIT3ASX1R1G05KX (Order no. 077890)

Description

Serial interface

The individual commands for reading and writing the data carriers are in accordance with the common 3964R protocol and are described in the EUCHNER CIS3 system manual (order no. 071 652). For data carrier programming away from the system, a convenient WINDOWS-compatible PC software application is available (Software Transponder Coding).

Standard housing

The size of the robust housing in degree of protection IP65 is compliant with the standard EN 50041. The division into 3 assemblies permits easy installation and straightforward replacement.

Attention:

On the use of a screened cable, the connecting cable for the serial interface is allowed to be max. 5 m long.

Dimension drawing
Dimension drawing
Wiring drawing<br>Terminal assignment
Wiring drawing
Terminal assignment

Dimension drawings

Dimension drawings
1Active face
2LED status indication
3Shield spring
mCenter offset
sRead distance

Connection examples

Connection examples

Technical data

Approvals

Richtlinie CE

Mechanical values and environment

Housing material
Housing Plastic
Ambient temperature 0 ... 55 °C
Degree of protection IP65
Connection Screw terminal
Cable length max.5 m RS232

Electrical connection ratings

Operating voltage DC 20 ... 24 ... 28 V DC (All the electrical connections must either be isolated from the mains supply by a safety transformer according to IEC/EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)
Current consumption max.140 mA
LED indicator
Green Operational
Yellow Data carrier in operating distance

Interface, bus

Data interface RS232
Data protocol 3964R via RS232 8 data bits, even parity
Data rate 9,6 kbit/s

In combination with Data carrier CIS3AP50X50SH16YSNOU, CIS3AP50X50SH16YSNOP

Actuating range

Read distance
At 25°C, center offset m=0mm 0 ... 20 ... 28 mm
Center offset
At 25°C, read distance s=20mm -13 ... 13 mm

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 2,5 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 077890
Item designation CIT3ASX1R1G05KX
Gross weight 0,378kg
Customs tariff number 85389099

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com