EUCHNER – More than safety.
EUCHNER – More than safety.

CIA3PL1G08 (Order no. 091875)

Read-only interface adapter CIA3PL1G08

  • Parallel interface
  • In combination with read head CIT3ASX1N12ST
  • Rail mounting
CIA3PL1G08 (Order no. 091875)

Description

Attention:

  • The connecting cable to the control system is allowed to be max. 15 m long.
  • On the use of a screened cable, the connecting cable to the read head is allowed to be max. 15 m long.
  • It is only ever possible to connect 1 read head per interface adapter.
Dimension drawing
Dimension drawing
Wiring drawing<br>Terminal assignment power supply and interface
Wiring drawing
Terminal assignment power supply and interface
Wiring drawing<br>Terminal assignment read head
Wiring drawing
Terminal assignment read head

Dimension drawings

Dimension drawings
1Suitable for 35 mm mounting rail according to DIN 46277

Connection examples

Connection examples

Connection examples

Connection examples

Technical data

Approvals

Richtlinie CE

Mechanical values and environment

Housing material
Housing PA6.6 gray
Ambient temperature 0 ... 55 °C
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Number of read heads max.1
Connection Plug-in screw terminal

Electrical connection ratings

Operating voltage DC 20 ... 24 ... 28 V DC (For use and operation as per the UL requirements, a power supply with the feature "for use in class 2 circuits" must be used.)
Current consumption
Without load 65 mA max.100 mA
LED indicator
Yellow ACTIVE LED data carrier active
Green STATE LED operational
Switching voltage
Ub-3 ... Ub V (High signal (A,B,C,D,Strobe))
0 ... 2 V (Low signal (A,B,C,D,Strobe))
Switching current
Per output - 30 ... +30 mA
Type of output Push-Pull
Connection cross-section 0,14 ... 2,5 mm²
Resistance 4,5 kΩ For inputs (Reset,Skip)
Input voltage
0 ... 2 V DC Low signal (Reset,Skip)
15 ... Ub V DC High signal (Reset,Skip)

Interface, bus

Data interface 4 bit binary coded + strobe

In combination with Read head CIT3ASX1N12ST and Data carrier CIS3AP10D05KH01K, CIS3AP10D05KH01K-P

Actuating range

Read distance
With center offset m=0 0 ... 3 ... 6,5 mm (These values apply for the surface installation of the read head and the data carrier.)
0 ... 3 ... 6 mm (These values apply for the surface installation of the read head and flush installation of the data carrier in iron.)
0 ... 3 ... 5 mm (These values apply for the surface installation of the read head and flush installation of the data carrier in aluminum.)
Center offset
Read distance s = 3 mm -2,5 ... 2,5 mm (These values apply for the surface installation of the read head and the data carrier.)

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 2,3 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 091875
Item designation CIA3PL1G08
Gross weight 0,21kg
Customs tariff number 85364110

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com