EUCHNER – More than safety.
EUCHNER – More than safety.

CMS-R-AZA-05PL (Order no. 103864)

Read heads, design A, for ESM, PUR

  • In combination with evaluation units ESM-BA...
  • Cube-shaped version, 88 x 25 mm
  • Connecting cable
  • 1 LED
  • Cable type: PUR
CMS-R-AZA-05PL (Order no. 103864)

Description

Alignment of read head and actuator

Operating diagram, design A

CMS-R-AZA

<p>CMS-R-AZA</p>
  • typ. operating distance
  • typ. release distance
Dimension drawing
Dimension drawing
Wiring drawing<br>CMS-R-AZA...
Wiring drawing
CMS-R-AZA...

Dimension drawings

Dimension drawings
1LED

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_5/2

Electrical connection ratings

Fusing
Power supply / safety contacts, external contact protection Fuse 10 A gG (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
rated conditional short-circuit current 100 A (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
Switching frequency, electrical
At nominal current 8A max. 0.1 Hz (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
at I_min = 10 mA max. 5 Hz (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
Switching current
DC max. 100 mA
Contact status indication max. 20 mA
Switching voltage
Contact status indication 24 ... 35 V (DC)
24 ... 35 V (DC)
Switching voltage according to UL
according to UL Class 2 max. 24 V AC/DC
Switching characteristics parallel
Switching delay from state change max. 26 ms (Parameter dependent on the evaluation units ESM-BA2.. and ESM-BA3..)
LED series resistance
LED contact status indication 1.5 kΩ

Mechanical values and environment

Number of LED displays 1 LED contact status indication
Number of NO contacts 2 NO contacts with fuse, 100 mA each, and 1 NO contact with LED
Connection hard-wired encapsulated cable with cable end sleeves 0.25mm2
Degree of protection IP67
Design A
Material
Cable material PUR
Housing Fiber glass reinforced PPS
Mechanical life 100 x 10⁶
Installation orientation any (During mounting it must be ensured that the marking arrows on the actuator and the read head are opposite each other.)
Tightening torque 0.4 ... 0.5 Nm
Classification according to EN IEC 60947-5-3 M3D88AS1
Cable length 5 m
Ambient temperature -20 ... +60 °C
Method of operation magnetic, reed contact

Reliability values acc. to EN ISO 13849-1

Classification according to EN IEC 60947-5-3 M3D88AS1
Monitoring of the guard position
B10D 20 x 10⁶

Miscellaneous

in compliance with EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN ISO 14119: 2013; IEC 60947-5-3: 2013

In combination with read head ESM-BA201, ESM-BA202, ESM-BA203, ESM-BA301, ESM-BA302, ESM-BA303, ESM-BA201P, ESM-BA301P and actuator CMS-M-AI

Assured operating distances sao
Contact status indication / LED min. 7 mm (These values apply only in approach direction X, center offset m=0.)
with center offset m=0 min. 9 mm (Value applies only if there is no ferromagnetic material in the vicinity of the read head and the actuator.)
Assured release distance sar
Contact status indication / LED max. 15 mm (These values apply only in approach direction X, center offset m=0.)
max. 20 mm (The assured release distance s_ar corresponds to the reset distance.)
Center offset
at s=3 mm read distance 2.5 mm (Value applies only if there is no ferromagnetic material in the vicinity of the read head and the actuator.)

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 3,7 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 103864
Item designation CMS-R-AZA-05PL
Gross weight 0,289kg
Customs tariff number 85389099

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com