Non-contact safety switch CES-AP-C01-...

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4 / PL e according to EN ISO 13849-1
  • M12 plug connector 5-pin
  • Multicode
CES-AP-C01-CH-SB-106798 (Order no. 106798)

Description

Approach direction

Can be adjusted in 90° steps

Short circuit monitoring

The switch generates its own clock signal on the output lines OA/OB.

Pay attention to this aspect when connecting to control systems and relays.

Multicode evaluation

Every suitable actuator is detected by the switch.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4/PL e according to EN 13849-1

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Additional connections

DIA

Diagnostics output (semiconductor)

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1UBPower supply, DC 24 VBN
2OASafety output, channel 1WH
30VGround, DC 0 VBU
4OBSafety output, channel 2BK
5DIAMonitoring outputGY
Dimension drawing
Dimension drawing
Wiring drawing<br>Wiring diagram
Wiring drawing
Wiring diagram

Dimension drawings

Dimension drawings
1LED status indication
2Active face

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1c_UL_us_E155795_3/2

Work area

Repeat accuracy R
according to EN 60947-5-2 <=10

Electrical connection ratings

Current consumption
no load on outputs max. 50 mA
Fusing
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 300 V (Tested by the employers’ liability insurance association up to 75V.)
Rated impulse withstand voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple < 5%, PELV
Turn-on time
Safety outputs max. 400 ms
EMC protection requirements according to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Safety class III
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output DIA
Output type p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
Switching current max. 200 mA
Safety outputs OA / OB
Output type Semiconductor outputs, p-switching, short circuit-proof
rated conditional short-circuit current max. 100 A
Discrepancy time max. 10 ms
Output voltage
HIGH U(OA,OB) UB-1.5 ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
LOW U(OA,OB) 0 ... 1 V DC
Switching current
per safety output 1 ... 400 mA
Utilization category
DC-13 24V 400mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Test pulses max. 0.4 ms

Mechanical values and environment

Connection M12 plug connector, 5-pin
Degree of protection IP67
Ready delay 0.5 s
Material
Housing Plastic, PBT
Installation orientation any
Switching frequency max. 1 Hz
Tightening torque
Fixing screws max. 1 Nm
Mounting distance min. 40 mm
Shock and vibration resistance according to EN IEC 60947-5-3
Ambient temperature -20 ... +55 °C

Reliability values acc. to EN ISO 13849-1

Mission time 20 y
Monitoring of the guard position
Category 4
Performance Level PL e
PFHD 2.1 x 10-9 (Applying the limit value from EN ISO 13849-1:2008, section 4.5.2 (MTTFd = max. 100 years), BG certifies a PFHd of max. 2.47x10-8.)

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BBA-071840

Assured operating distances sao min. 15 mm (The values apply to surface mounting)
Assured release distance sar max. 45 mm (The values apply to surface mounting)
Operating distance 18 mm
Switching hysteresis 1 ... 3 mm (The values apply to surface mounting)
Mounting distance

In combination with actuator CES-A-BRN-100251

Assured operating distances sao min. 20 mm (The values apply to surface mounting of the actuator on steel.)
Assured release distance sar max. 75 mm
Operating distance 27 mm
Switching hysteresis 3 mm (The values apply to surface mounting of the actuator on steel.)
Mounting distance

In combination with actuator CES-A-BDA-18-156935

Assured operating distances sao min. 10 mm (The values apply to surface mounting)
Assured release distance sar max. 45 mm (The values apply to surface mounting)
Operating distance 19 mm (The values apply to surface mounting)
Switching hysteresis 1 ... 3 mm (The values apply to surface mounting)
Mounting distance

In combination with actuator CES-A-BPA-098775

Assured operating distances sao min. 18 mm
Assured release distance sar max. 58 mm
Operating distance 22 mm (on surface mounting on aluminum. In a non-metallic environment, the typical operating distances increase to 30 mm)
Switching hysteresis 1 ... 2 mm
Mounting distance

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 13,5 MB)

Single Documents

Doc. no.
Version
Language
Size
Doc. no. 2112663
Operating Instructions Non-Contact Safety Switch CES-AP-C01-... (Unicode/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,4 MB
Doc. no. 2112663
Mode d'emploi Interrupteur de sécurité sans contact CES-AP-C01-... (uni-/multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,4 MB
Doc. no. 2112663
Manual de instrucciones Interruptor de seguridad sin contacto CES-AP-C01-... (Unicode/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,4 MB
Doc. no. 2112663
Betriebsanleitung Berührungsloser Sicherheitsschalter CES-AP-C01-... (Uni-/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,4 MB
Doc. no. 2112663
Manual de instruções Chaves de segurança sem contato CES-AP-C01-... (Unicode/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,4 MB
Doc. no. 2112663
Istruzioni di impiego Finecorsa di sicurezza senza contatto CES-AP-C01-… (Unicode/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,4 MB
Doc. no. 2112663
使用说明书 非接触式安全开关 CES-AP-C01-⋯ (特殊/通用编码)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,6 MB
Doc. no. 2112663
Инструкция по эксплуатации Бесконтактный предохранительный выключатель CES-AP-C01-... (Uni-/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,6 MB
Doc. no. 2112663
Návod k použití Bezkontaktní bezpečnostní spínač CES-AP-C01-... (Unicode/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
2,5 MB
Doc. no. 2112663
Kezelési útmutató Érintkezésmentes biztonsági kapcsoló CES-AP-C01-... (uni-/multikód)
Doc. no.
2112663
Version
08-02/20
Language
Size
2,5 MB
Doc. no. 2112663
Instrukcja obsługi Bezstykowy wyłącznik bezpieczeństwa CES-AP-C01-... (Uni-/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
2,5 MB
Doc. no. 2112663
Návod na prevádzku Bezdotykový bezpečnostný spínač CES-AP-C01-... (Uni-/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
2,5 MB

Other Documents

Ordering data

Ordernumber 106798
Item designation CES-AP-C01-CH-SB-106798
Gross weight 0,191kg
Customs tariff number 85365019

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com