Evaluation module with control and bus module MGB-...-PN with 11 controls and indicators, push-pull plug, RC12
- Control panel
- Emergency stop according to ISO 13850
- 8 illuminated pushbuttons
- Operating mode selector
- 1 indicator
- including adhesive labels
- Push-pull plug
- including terminal plug for enabling switch (RC12, 12-pin)
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
Description
Profinet connection
Connection via push-pull plugs according to IEC 61076-3-117
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Dimensional drawings
Technical data
Approvals
Workspace
Secured switch-off distance sar | |
Door position | max. 65 mm |
Operating and display elements
Occupancy diagram | |
B2 | |
C3 | |
L2 |
Item | Color | Extras | Slide-in label | Version | Note slide-in label | Switching element | Number | Designation1 | LED |
---|---|---|---|---|---|---|---|---|---|
1 | Green | Inicia estação | Illuminated pushbutton | 1NO | |||||
11 | Green | Área segura | Cover for indicators | ||||||
12 | Yellow | Rearma área segura | Illuminated pushbutton | 1NO | |||||
13 | Destravada ; Travada ; Travada central | Operating mode selector | Code 2 of 3 | ||||||
2 | Red | Para estação | Illuminated pushbutton | 1NO | |||||
3 | Green | Liga água de refrigeração | Illuminated pushbutton | 1NO | |||||
4 | white | Fim de ciclo | Illuminated pushbutton | 1NO | |||||
5 | white | ohne Aufschrift | Illuminated pushbutton | 1NO | |||||
6 | Red | Desliga água de refrigeração | Illuminated pushbutton | 1NO | |||||
7 | Emergency stop | 2 PD | |||||||
8 | white | Libera porta de segurança | Illuminated pushbutton | 1NO |
Electrical connection values
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0.5 kV |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
maximum feed-in current in the connection block | |
X1, X2 | max. 4000 mA |
Safety class | III |
Current consumption | max. 500 mA |
Transponder coding | Multicode |
Degree of contamination (external, according to EN 60947-1) | 3 |
Power supply X1 | |
Fuse | |
external | min. 1 A slow blow |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% (For looping through for connected devices) |
Mechanical values and environment
Connection type | |
for enabling switch | Plug connector RC12 (X14) |
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 (X4 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.)) |
Push-pull power (X1 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.)) | |
Push-pull power (X2 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.)) | |
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 (X3 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.)) |
Installation orientation | Door hinge DIN left |
Switching frequency | 0.25 Hz |
Mechanical life | |
in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ |
1 x 10⁶ | |
Response time | |
Door position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Enabling switch | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Emergency stop / machine stop | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Operating mode selector | max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Guard locking | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Bolt position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP54 |
Ambient temperature | |
at UB = 24 V DC | -20 ... +55 °C |
Material | |
Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel |
Locking force FZh | 2000 N |
Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
Enabling switch evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | 3 | 4.07x10-8 | 4 | 20 y |
Monitoring of guard locking | PL e | 3 | 4.07x10-8 | 4 | 20 y |
Safe multi-position switch | PL e | 3 | 4.1x10-8 | 4 | 20 y |
Evaluating safety signals | PL e | 3 | 4.1x10-8 | 4 | 20 y |
Applies to all additionally included safety functions such as EMERGENCY STOP, enabling switch, etc. |
B10D | Mission time | |
---|---|---|
Emergency stop | 0.13x106 | 20 y |
Miscellaneous
Product version number | V3.30.10 |
Interface
Bus data protocol | Profinet (IEC 61158 type 10) |
Safety data protocol | Profisafe (IEC 61784-3-3) |
Date interface | |
Ethernet |
Accessories
ZSA
ZSA, 3-stage, with cable and plug connector RC12
092141
ZSA092141C2038
ZSA092141C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 5 m
- Direct connection to safety switch
097567
ZSA097567C2038
ZSA097567C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 10 m
- Direct connection to safety switch
099495
ZSA099495C2038
ZSA099495C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 15 m
- Direct connection to safety switch
100873
ZSA100873C2038
ZSA100873C2038
- Housing G1
- 3-stage function
- Straight connecting cable with plug connector, 25 m
- Direct connection to safety switch
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size
EU-Konformitätserklärung
Doc. no.
EDC2123624
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size
UKCA-Konformitätserklärung
Doc. no.
EDC20001506
Version
Language
Size
0,1 MB
Instructions
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type A
Doc. no.
Version
Language
Size
Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type A
Doc. no.
2114575
Version
03/24
Language
Size
3,4 MB
Betriebsanleitung Sicherheitssysteme MGB-L..B-PN.-… (PROFINET) und mit Datenstruktur Typ A
Doc. no.
2114575
Version
03/24
Language
Size
3,4 MB
Other Documents
Application examples
Approvals and certificates
TUEV Süd München M6A Zertifikat
Doc. no.
Version
Language
Size
TUEV Süd München M6A Zertifikat
Doc. no.
Version
Language
Size
0,3 MB
c UL us
Doc. no.
Version
Language
Size
c UL us
Doc. no.
Version
Language
Size
0,7 MB
Ordering data
Ordernumber | 114777 |
Item designation | MGB-L2CB-PNC-L-114777 |
Gross weight | 4,54kg |
Customs tariff number | 85371098 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |