MSC-CB-AC-FI8FO2-121289 (Order no. 121289)
Base unit MSC-CB
- Freely programmable base unit for use as a standalone device or expandable with various expansion modules
- 8 single-channel /4 dual-channel inputs
- 2 control inputs
- 2 dual-channel semiconductor outputs (PL e, category 4)
- 2 monitoring outputs
- PC connection for the “EUCHNER Safety Designer” software
- Optional memory module for configuration
- Compact housing with width of only 22.5mm
- Simple diagnostics via LED displays

Description
Combination options
The following table provides information about the options for combining the expansion modules with the related base unit.
| Base unit | MSC-CE-...S | MSC-CE-... |
|---|---|---|
| MSC-CB-AC-FI8F04S | • | • |
| MSC-CB-AC-FI8F02 | - | • |
Inputs and outputs
- 8 single-channel/4 dual-channel inputs
- 2 control inputs for starting/restarting semiconductor outputs or for external device monitoring (EDM)
- 2 dual-channel semiconductor outputs (PL e, category 4)
- 4 test outputs for monitoring for short circuits and overload states
- 2 monitoring outputs programmed via the software "EUCHNER Safety Designer"
MSC system
An MSC system consists of a base unit and max. 14 expansion modules. You can use this base unit to expand your MSC system with max. 128 inputs, 16 dual-channel safe outputs and 32 monitoring outputs. You can use up to 4 expansion modules of the same time in your MSC system.
Accessories
- Plug-in screw terminals (order no. 121321) must be ordered separately
- An expansion plug (order no. 121308) is also required for use with expansion modules
Dimensional drawings

| 1 | Page A |
| 2 | Page B |
Connection examples

Technical data
Approvals




Electrical connection values
| Connection cross section | 0.5 ... 2.5 mm² (Screw terminal) | Outputs | |||||||||||||||
| |||||||||||||||||
| Output voltage | |||||||||||||||||
| Safety outputs (OSSD) | 0 ... 2 V DC LOW | ||||||||||||||||
| Safety outputs (OSSD) | UB-0.75 ... UB V DC HIGH | ||||||||||||||||
| Output current | |||||||||||||||||
| Monitoring outputs, programmable | max. 100 mA | ||||||||||||||||
| Safety outputs (OSSD) | 0 ... 400 mA | ||||||||||||||||
| Operating voltage DC | |||||||||||||||||
| UB | 24 V DC -20% ... +20% PELV (according to EN 60204-1) | Inputs | |||||||||||||||
| |||||||||||||||||
| inductive load | |||||||||||||||||
| Safety outputs (OSSD) | max. 2 mH | ||||||||||||||||
| capacitive load | |||||||||||||||||
| Safety outputs (OSSD) | max. 0.82 μF | ||||||||||||||||
| Test pulse duration | |||||||||||||||||
| Test outputs | 0.2 ms | ||||||||||||||||
| Safety outputs (OSSD) | 0.1 ms | ||||||||||||||||
| Test pulse interval | 20 ms | ||||||||||||||||
| Overvoltage category according to IEC EN 60664-1 | II | ||||||||||||||||
| Power dissipation | max. 3 W | ||||||||||||||||
| Degree of contamination according to EN 60664-1 | 2 | ||||||||||||||||
| Time delay | 0.0106 ... 0.0546 s + filter time (Depending on the number of slave modules, operators and OSSD outputs. (See operating instructions or calculated values in the “Euchner Safety Designer” software)) | ||||||||||||||||
Mechanical values and environment
| Dimensions | 108 x 22.5 x 114.5 (Including screw terminals) |
| Connection type | Plug-in screw terminal (Terminals not included) |
| Storage temperature | -20 ... 85 °C |
| Cable length | max. 100 m (with length above 50 m, use cross-section>1 mm²) |
| Atmospheric humidity | 10 ... 95 % rH |
| Mounting type | Mounting rail TH 35 (EN IEC 60715) |
| Degree of protection | IP20 |
| Ambient temperature | -10 ... 55 °C |
| Material | |
| Housing | Polyamide |
| USB port for PC connection | |
| Connection type | USB type B - Mini |
| Cable length | max. 3 m |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| Mission time | 20 y (according to ISO 13849-1:2006/IEC 62061:2005) |
| Category | 4 (according to ISO 13849-1:2006/IEC 62061:2005) |
| Performance Level | PL e (according to ISO 13849-1:2006/IEC 62061:2005) |
| PFHD | 6.85E-9 1/h (according to IEC 61508:2010) |
| SIL CL | 3 |
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Basismodul MSC-CB-AC-FI8FO2
Other Documents
Ordering data
| Ordernumber | 121289 |
| Item designation | MSC-CB-AC-FI8FO2-121289 |
| Gross weight | 0,22kg |
| Customs tariff number | 85371091 |
| ECLASS | 27-24-22-07 SPS-Grundgerät |