MGB-L2HB-EIA-R-127677 (Order no. 127677)
									Choose content
									
									
									
									
									
									
									
									
									
									Locking set MGB-L2...-EI (guard locking by solenoid force) with 2 pushbuttons, emergency stop
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 2 illuminated pushbuttons
- including adhesive labels
- Connection via M12 plug
- Pre-assembled on mounting plates
- Unicode

Description








Dimensional drawings

Connection examples

Technical data
Approvals


Handle modules MGB-H-AA1A6-R-111838 (Order no. 111838)
 
    Mechanical values and environment
| Installation orientation | Door hinge DIN right | 
| Degree of protection | IP65 | 
| Ambient temperature | -20 ... 55 °C | 
| Material | |
| Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel | 
Miscellaneous
| Product version number | V3.0.0 | 
| Additional feature | with mounting plate and automatic lockout mechanism | 
Locking modules MGB-L2B-EIA-R-127676 (Order no. 127676)
 
    Workspace
| Secured switch-off distance sar | |
| Only with sliding door | 20 mm (Only applies for use on sliding doors with deactivated guard lock monitoring) | 
Operating and display elements
| Occupancy diagram | |
| B0 | |
| L1 | 
| Item | Color | Extras | Slide-in label | Switching element | Note slide-in label | Version | Number | Designation1 | LED | 
|---|---|---|---|---|---|---|---|---|---|
| 1 | with adhesive ring | 2 PD | Emergency stop illuminated | ||||||
| 2 | 1NO | Illuminated pushbutton | |||||||
| 3 | 1NO | Illuminated pushbutton | 
Electrical connection values
| Connecting cable | |
| Ethernet | Ethernet/IP cable, at least cat. 5e | 
| Rated insulation voltage Ui | 75 V | 
| Rated impulse voltage Uimp | 0.5 kV | 
| EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 | 
| maximum feed-in current in the connection block | |
| X1, X2 | max. 4000 mA | 
| Safety class | III | 
| Current consumption | max. 500 mA | 
| Transponder coding | Unicode | 
| Degree of contamination (external, according to EN 60947-1) | 3 | 
| Power supply X1 | |
| Fuse | |
| external | min. 1 A slow blow | 
| Operating voltage DC | |
| L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) | 
| Auxiliary voltage DC | |
| L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) | 
| Power supply X2 | |
| Operating voltage DC | |
| L1 | 24 V DC -15% ... +10% (For looping through for connected devices) | 
| Auxiliary voltage DC | |
| L2 | 24 V DC -15% ... +10% (For looping through for connected devices) | 
Mechanical values and environment
| Connection type | |
| Ethernet/IP cable, at least cat. 5e | M12, D-coded, screened (X4) | 
| M12 Power, A-coded (X2) | |
| Ethernet/IP cable, at least cat. 5e | M12, D-coded, screened (X3) | 
| M12 Power, A-coded (X1) | |
| Installation orientation | Door hinge DIN right | 
| Switching frequency | 0.25 Hz | 
| Mechanical life | |
| in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ | 
| 1 x 10⁶ | |
| Response time | |
| Emergency stop / machine stop | max. 100 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Door position | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Bolt position | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Guard locking | max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 | 
| Degree of protection | IP54 | 
| Ambient temperature | |
| at UB = 24 V DC | -20 ... 55 °C | 
| Material | |
| Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel | 
| Locking force FZh | 2000 N | 
| Guard locking principle | Open-circuit current principle | 
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| Mission time | 20 y | 
| Safety Integrity Level | SIL 3 (EN 62061:2005) | 
| Control of guard locking | |
| Category | 4 | 
| Performance Level | PL e | 
| PFHD | 4.91 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) | 
| Emergency stop | |
| B10D | |
| Emergency stop | 0.13 x 10⁶ | 
| Emergency-stop evaluation | |
| Category | 4 | 
| Performance Level | PL e | 
| PFHD | 3.05 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) | 
| Monitoring of guard locking and the guard position | |
| Diagnostic Coverage (DC) | 99 % | 
| Category | 4 | 
| Performance Level | PL e | 
| PFHD | 3.37 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.) | 
Miscellaneous
| Slide-in label | |||||||
| 
 | |||||||
| Product version number | V1.5 | ||||||
| Additional feature | incl. lens set, ID no. 120344 | ||||||
Interface
| Bus data protocol | Ethernet/IP | 
| Safety data protocol | CIP Safety | 
| Date interface | |
| Ethernet | 
Components

				111838
MGB-H-AA1A6-R-111838
Handle module MGB-H... with automatically extending lockout mechanism
				MGB-H-AA1A6-R-111838
Handle module MGB-H... with automatically extending lockout mechanism
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Mounting plate

				127676
MGB-L2B-EIA-R-127676
Locking module MGB-L2...-EI (guard locking by solenoid force) with 2 pushbuttons, emergency stop
				MGB-L2B-EIA-R-127676
Locking module MGB-L2...-EI (guard locking by solenoid force) with 2 pushbuttons, emergency stop
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850, illuminated
- 2 illuminated pushbuttons
- including adhesive labels
- Connection via M12 plug
- Pre-assembled on mounting plates
- Unicode
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
							Download Complete Package (ZIP, 11,2 MB)
						
Single Documents
				
				Declarations of conformity
				
				
				
				
					
						EU-Konformitätserklärung
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

EU-Konformitätserklärung
Doc. no.
										EDC2123624
Version
										Language
										Size
										0,2 MB
					
						UKCA-Konformitätserklärung
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

UKCA-Konformitätserklärung
Doc. no.
										EDC20001506
Version
										Language
										Size
										0,1 MB
				
				Instructions
				
				
				
				
					
						Operating Instructions Safety Systems MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A From V1.5.0
					
					
					
					
					
						 
						
					
						 
						
					
						 
						
					
						 
						
					
						 
						
Doc. no.
Version
Language
Size

Operating Instructions Safety Systems MGB-L..B-EI-… (Ethernet/IP) and With Data Structure Type A From V1.5.0
Doc. no.
										2126330
Version
										09/21
Language
										Size
										2,9 MB

Manual de instrucciones Sistemas de seguridad MGB-L..B-EI-… (Ethernet/IP) y con estructura de datos de tipo A V1.5.0 o superior
Doc. no.
										2126330
Version
										09/21
Language
										Size
										3,0 MB

Betriebsanleitung Sicherheitssysteme MGB-L..B-EI-… (Ethernet/IP) und mit Datenstruktur Typ A ab V1.5.0
Doc. no.
										2126330
Version
										09/21
Language
										Size
										2,9 MB

사용 설명서 안전 시스템 MGB-L..B-EI-…(이더넷/IP) 데이터 구조 타입 A 포함 V1.5.0부터
Doc. no.
										2126330
Version
										09/21
Language
										Size
										3,3 MB

Instrucțiuni de utilizare Sisteme de siguranță MGB-L..B-EI-… (Ethernet/IP) și cu structură de date tip A începând de la versiunea V1.5.0
Doc. no.
										2126330
Version
										09/21
Language
										Size
										3,1 MB
Other Documents
				
				Application examples
				
				
				
				
				
				Approvals and certificates
				
				
				
				
					
						WEEE
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

WEEE
Doc. no.
										ECO20001806
Version
										Language
										Size
										0,1 MB
					
						c UL us
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

c UL us
Doc. no.
										Version
										Language
										Size
										0,7 MB
Ordering data
| Ordernumber | 127677 | 
| Item designation | MGB-L2HB-EIA-R-127677 | 
| Gross weight | 5,864kg | 
| Customs tariff number | 85371098 | 
| ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking | 
 
				