									Evaluation module and bus module MGB-L1...-PN... (guard locking by spring force) with 5 control elements, emergency release, 7/8" and M12 plugs
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850
- 3 illuminated pushbuttons
- SSG10 key-operated rotary switch
- Connection via 7/8" and M12 plugs
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Unicode

Description
Profinet connection
7/8" plugs according to ANSI/B93.55M-1981 and M12 plugs (d-coded) according to IEC 61076-2-101
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Flexible use as interlocking or guard locking
By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring).


Dimensional drawings

Connection examples

Technical data
Approvals




Workspace
| Secured switch-off distance sar | |
| Only with sliding door | 20 mm (Only applies for use on sliding doors with deactivated guard lock monitoring) | 
Operating and display elements
| Occupancy diagram | |
| B1 | |
| L1 | 
| Item | Color | Extras | Note slide-in label | Version | Slide-in label | Switching element | Number | Designation1 | LED | 
|---|---|---|---|---|---|---|---|---|---|
| 1 | Emergency stop | 2 PD | |||||||
| 2 | white | printed | Illuminated pushbutton | 1NO | |||||
| 3 | red | Illuminated pushbutton | 1NO | ||||||
| 4 | green | printed | Illuminated pushbutton | 1NO | |||||
| 94 | SSG10 | Key-operated rotary switch | 1NO | 
Electrical connection values
| Connecting cable | |
| Ethernet | Profinet I/O cable, at least cat. 5e | 
| Rated insulation voltage Ui | 75 V | 
| Rated impulse voltage Uimp | 0.5 kV | 
| EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 | 
| maximum feed-in current in the connection block | |
| X1, X2 | max. 4000 mA | 
| Safety class | III | 
| Current consumption | max. 500 mA | 
| Transponder coding | Unicode | 
| Degree of contamination (external, according to EN 60947-1) | 3 | 
| Power supply X1 | |
| Fuse | |
| external | min. 1 A slow blow | 
| Operating voltage DC | |
| L1 | 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV)) | 
| Auxiliary voltage DC | |
| L2 | 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system) | 
| Power supply X2 | |
| Operating voltage DC | |
| L1 | 24 V DC -15% ... +10% (For looping through for connected devices) | 
| Auxiliary voltage DC | |
| L2 | 24 V DC -15% ... +10% (For looping through for connected devices) | 
Mechanical values and environment
| Connection type | |
| according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X4 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) | 
| according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e | M12, D-coded, screened (X3 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) | 
| 7/8" Power (X2 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) | |
| 7/8" Power (X1 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.)) | |
| Installation orientation | Door hinge DIN right | 
| Switching frequency | 0.25 Hz | 
| Storage temperature | -25 ... 70 °C | 
| Mechanical life | |
| in case of use as door stop, and 1 Joule impact energy | 0.1 x 10⁶ | 
| 1 x 10⁶ | |
| Response time | |
| Guard locking | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Bolt position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Door position | max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.) | 
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 | 
| Degree of protection | IP54 | 
| Ambient temperature | |
| at UB = 24 V DC | -20 ... 55 °C | 
| Material | |
| Housing | Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel | 
| Locking force FZh | 2000 N | 
| Guard locking principle | Closed-circuit current principle | 
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Control of guard locking | PL e | - | 3.91x10-8 | 4 | 20 y | 
| Monitoring of the guard position | PL e | 3 | 4.07x10-8 | 4 | 20 y | 
| Guard lock monitoring | PL e | 3 | 4.07x10-8 | 4 | 20 y | 
Miscellaneous
| Product version number | V3.30.10 | 
Interface
| Bus data protocol | Profinet (IEC 61158 type 10) | 
| Safety data protocol | Profisafe (IEC 61784-3-3) | 
| Date interface | Ethernet | 
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
							Download Complete Package (ZIP, 6,6 MB)
						
Single Documents
				
				Declarations of conformity
				
				
				
				
					
						EU-Konformitätserklärung
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

EU-Konformitätserklärung
Doc. no.
										EDC2123624
Version
										Language
										Size
										0,2 MB
					
						UKCA-Konformitätserklärung
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

UKCA-Konformitätserklärung
Doc. no.
										EDC20001506
Version
										Language
										Size
										0,1 MB
				
				Instructions
				
				
				
				
					
						Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type B
					
					
					
					
					
						 
						
					
						 
						
Doc. no.
Version
Language
Size

Operating Instructions Safety Systems MGB-L..B-PN.-… (PROFINET) and With Data Structure Type B
Doc. no.
										2115174
Version
										03/24
Language
										Size
										3,9 MB

Betriebsanleitung Sicherheitssysteme MGB-L..B-PN.-… (PROFINET) und mit Datenstruktur Typ B
Doc. no.
										2115174
Version
										03/24
Language
										Size
										3,9 MB
Other Documents
				
				Approvals and certificates
				
				
				
				
					
						FCC
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

FCC
Doc. no.
										20001708
Version
										Language
										Size
										0,1 MB
					
						Profisafe
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

Profisafe
Doc. no.
										Version
										Language
										Size
										0,2 MB
					
						TUEV Süd München
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

TUEV Süd München
Doc. no.
										Version
										Language
										Size
										0,4 MB
					
						WEEE
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

WEEE
Doc. no.
										ECO20001806
Version
										Language
										Size
										0,1 MB
					
						c UL us
					
					
					
					
					
						 
						
Doc. no.
Version
Language
Size

c UL us
Doc. no.
										Version
										Language
										Size
										0,7 MB
Ordering data
| Ordernumber | 136428 | 
| Item designation | MGB-L1B-PNA-R-136428 | 
| Gross weight | 3,5kg | 
| Global Trade Item Number (GTIN) | 4047048006997 | 
| Customs tariff number | 85371098 | 
| ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking | 
 
				