EUCHNER – More than safety.
EUCHNER – More than safety.

CTP-L1-AP-U-HA-ZE-SII-136627 (Order no. 136627)

Transponder-coded safety switch CTP-AP, 2 x M12, with escape release

  • Safety switch with guard locking and integrated evaluation electronics
  • Direct connection to decentralized peripheral systems (e.g. ET200pro)
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • Unicode
  • With escape release
  • Approach directions A, B and C (delivery state)
CTP-L1-AP-U-HA-ZE-SII-136627 (Order no. 136627)

Description

Approach direction

Horizontal

Can be adjusted in 90° steps

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Guard locking type

CTP‑L1

Guard locking actuated by spring force and power-ON released (closed-circuit current principle).

Escape release

This is used for manual release of guard locking from the danger zone without tools.

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

X 1.1UBOperating voltage of AP electronics, 24 V DCBN
X 1.2FO1ASafety output, channel 1WH
X 1.30 V UBAP electronics operating voltage, 0 VBU
X 1.4FO1BSafety output, channel 2BK
X 1.5-Not usedGY
X 2.1-Not usedBN
X 2.2-Not usedWH
X 2.3IMMControl input of guard locking solenoid 0 VBU
X 2.4IMPControl input of guard locking solenoid, 24 V DCBK
X 2.5-Not usedGY
Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
Wiring drawing
Wiring drawing
CTP: Transponder coded safety switch CTP

Dimension drawings

Dimension drawings
1LEDs

Dimension drawings

Dimension drawings

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20DGUV_CTP_ET 22017_ET 22018c_UL_us_E155795_3/11FCC_2AJ58-05_

Work area

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection ratings

Power consumption 6 W
Current consumption
IUB 40 mA
IIMP 400 mA
Fusing
external (solenoid operating voltage IMP) 0.5 ... 8 A
external (operating voltage UB) 0.25 ... 8 A
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple < 5%, PELV
EMC protection requirements according to EN IEC 60947-5-3
Utilization category
DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Solenoid operating voltage DC
UIMP 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple < 5%, PELV
Solenoid duty cycle 100 %
Switching load
according to UL 24V DC, Class 2 (alternatively, see operating instructions)
Safety class
EN IEC 61140 III
Test pulses max. 0.3 ms (Applies to a load with C <= 30 nF and R <= 20 kohm)
Test pulse interval min. 100 ms
Degree of contamination (external, according to EN 60947-1) 3
Safety outputs FO1A/FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Discrepancy time
both safety outputs max. 10 ms according to EN IEC 60947-5-3
Output voltage
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
Turn-on time max. 400 ms
Switching current
per safety output FO1A / FO1B 1 ... 150 mA
Off-state current Ir max. 0.25 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection 2 plug connectors M12, 5-pin + pin 5 not used
Degree of protection IP67/IP69/IP69K (screwed tight plug connector/mating component)
Extraction force 20 N
Ready delay max. 1 s
Material
Switch head cover Die-cast zinc
Safety switch housing reinforced thermoplastic
Actuating force 10 N
Mechanical life 1 x 10⁶
Installation orientation any
Switching frequency max. 0.5 Hz
Overtravel 5 mm
Retention force 20 N
Shock and vibration resistance according to EN IEC 60947-5-3
Ambient temperature
at UB = 24V DC -20 ... +55 °C
Locking force Fmax 3900 N
Locking force FZh 3000 N (Fzh = Fmax/1.3, depending on the actuator used)
Guard locking principle Closed-circuit current principle

Reliability values acc. to EN ISO 13849-1

Mission time 20 y
Category 4
Performance Level PL e
PFHD 4.1 x 10 -9

Miscellaneous

Additional feature
Escape release actuated by pushing
Cover without auxiliary release
The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 12,9 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 136627
Item designation CTP-L1-AP-U-HA-ZE-SII-136627
Gross weight 0,8kg
Customs tariff number 85365019

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com