ECB-A-2K-A2-160398 (Order no. 160398)

Euchner Control Box ECB

  • Safe entry into hazardous areas
  • Can be used as a trapped key system or as a safe lockout bar
  • Two key adapters installed in housing
  • Integrated evaluation unit with two safe relay outputs
  • Transponder-coded keys (unique)
  • Connection of the ECB via 1 x M12/8-pin plug connector
ECB-A-2K-A2-160398 (Order no. 160398)

Description

Note

Keys are included

Functional description

In combination with a control system, the Euchner Control Box allows dangerous machine movements to be performed as long as all valid unique, transponder-coded keys (CKS keys) are inserted. If at least one CKS key is removed during operation, the two safety contacts are switched off and a stop command is triggered. The safety contacts remain switched off when the CKS key is removed. The installation cannot be restarted.

Function as lockout bar

When the CKS keys are removed from an ECB device up to two persons can access the hazardous area for servicing. As long as the operator carries the CKS key with him, there is no hazard for the operator due to unexpected machine start-up or being locked into the machine unintentionally. The ECB therefore performs the function of a safe lockout bar. The system can fulfill its safety function only if the users always carry their CKS keys with them when accessing the machine.

Function as trapped key system

When the CKS key is removed, the operator can enter the hazardous area safely and can use the same CKS key to start local machine functions via another ECB device.

Safety characteristics according to EN ISO 13849-1

Monitoring of the CKS keys (prevention of unexpected start-up of a machine when the key is removed) Category 4 Performance Level (PL) e

Connector assignment

Plug connector (view of connection side)PinDesignationFunction

X 1.113Enable input for channel 1
X 1.2UBOperating voltage, 24 V DC
X 1.324Safety output, channel 2
X 1.414Safety output, channel 1
X 1.5n.c.-
X 1.623Enable input for channel 2
X 1.70 V UBOperating voltage, 0 V DC
X 1.8n.c.-
Wiring diagram
Wiring diagram
Wiring diagram
Wiring diagram

Connection examples

Connection examples

Connection examples

Connection examples
1X1: connection to PLC
2Cable outlet C (left)
3Cable outlet A (right)

Technical data

Electrical connection values

Fuse
external (safety circuit) according to EN 60269-1 6 A (6 AgG or 6 A circuit breaker (characteristic B or C))
external (operating voltage UB) 0.4 ... 8 A
rated conditional short-circuit current 100 A
Rated insulation voltage Ui
DC 75 V
Rated impulse withstand voltage Uimp 0.8 kV
Operating voltage DC
UB 21 ... 24 ... 27 V DC (regulated, residual ripple<5%)
Discrepancy time
between the operating points of both safety relays max. 25 ms
EMC protection requirements EN 60947-5-3
Utilization category
AC-12 30 V 1.5 A
DC-12 30 V 0.3 A
AC-12 30 V 0.3 A
DC-12 30 V 1.5 A
DC-13 24 V 1.5 A
Switching current
Relay outputs at switching voltage AC/DC 5 ... 30 V 10 ... 1500 mA
Safety class III
Current consumption
with relay energized 150 mA
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Dimensions 160 x 160 x 150
Connection type 1 x plug connectors M12, 8-pin
Number of safety inputs 2 (relays with internally monitored contacts)
Ready delay 10 ... 12 s (After the operating voltage is switched on, the relay outputs are switched off and the monitoring outputs are set to LOW level during the ready delay. For visual indication of the delay, the green STATE LED flashes at a frequency of approx. 15 Hz.)
Atmospheric humidity
not condensing max. 80 % rH
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65
Ambient temperature -20 ... +45 °C
Material
Housing seal Silicone
Housing Stainless steel 1.4301

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Monitoring of the CKS keys
Number of switching cycles
≤ 0.1 A 760000 1/y
≤ 1 A 153000 1/y
Diagnostic Coverage (DC) 99 %
Mission time 20 y (This value is dependent on the number of switching cycles and the switching current.)
Category 4 (This value is dependent on the number of switching cycles and the switching current.)
Performance Level PL e (This value is dependent on the number of switching cycles and the switching current.)
PFHD
ECB 1.9 x 10-8 (This value is dependent on the number of switching cycles and the switching current.)

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 10,5 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 160398
Item designation ECB-A-2K-A2-160398
Gross weight 3,285kg
Customs tariff number 85365019000

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.