CTP-L1-AP-U-HA-AES-SII-175302 (Order no. 175302)
Transponder-coded safety switch CTP-AP, 2 x M12
- Safety switch with guard locking and integrated evaluation electronics
- Version with stainless-steel components
- ECOLAB certificate
- Direct connection to decentralized peripheral systems (e.g. ET200pro)
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- With escape release
- Approach directions A, B and C (delivery state)

Description
medium-resistant stainless-steel version
robust, tough and largely media resistant. Critical components such as plugs, cover screws and guide bushes, etc., consist of high-quality inox steel.
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.
Guard locking type
CTP‑L1 | Guard locking actuated by spring force and power-ON released (closed-circuit current principle). |
Escape release
This is used for manual release of guard locking from the danger zone without tools.
Connector assignment


Dimensional drawings

Connection examples

Technical data
Approvals


Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | 10 % |
Electrical connection values
Fuse | |
external (solenoid operating voltage IMP) | 0.5 ... 8 A |
external (operating voltage UB) | 0.25 ... 8 A |
Power consumption | 6 W |
Rated insulation voltage Ui | 50 V |
Rated impulse voltage Uimp | 0.5 kV |
Operating voltage DC | |
UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Utilization category | |
DC-13 | 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% reverse polarity protected, regulated, residual ripple<5%, PELV |
Solenoid duty cycle | 100 % |
Switching load | |
according to UL | 24V DC, Class 2 (alternatively, see operating instructions) |
Safety class | III |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Test pulse duration | max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm) |
Test pulse interval | min. 100 ms |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety outputs FO1A / FO1B | |
Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
Discrepancy time | |
both safety outputs | max. 10 ms Acc. to EN IEC 60947-5-3 |
Turn-on time | max. 400 ms |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output FO1A / FO1B | 1 ... 150 mA |
Mechanical values and environment
Approach speed | max. 20 m/min |
Connection type | 2 plug connector M12, 5-pin |
Extraction force | 20 N |
Ready delay | max. 1 s |
Actuating force | 10 N |
Installation orientation | any |
Switching frequency | max. 0.5 Hz |
Mechanical life | 1 x 10⁶ |
Overtravel | 5 mm |
Retention force | 20 N |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67/IP69/IP69K (When inserted and secured) |
Ambient temperature | |
with UB = 24 V DC | -20 ... +55 °C |
Material | |
Safety switch housing | Reinforced thermoplastic |
Actuating button | Thermoplastic |
Metal material | Stainless steel |
Seals | NBR |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N (Fzh = Fmax/1.3, depending on the actuator used) |
Guard locking principle | Closed-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of guard locking | PL e | - | 4.1x10-9 | 4 | 20 y |
PL | Maximum SIL | Category | Mission time | |
---|---|---|---|---|
Control of guard locking | Depending on external control of guard locking | 20 y |
Miscellaneous
Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Additional feature | Escape release actuated by pushing |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents









Other Documents







Fiches info
Ficha informativa
Fichas de informação
信息表
情報シート
정보 시트
Informační listy


Fiches info
Ficha informativa
Fichas de informação
信息表
情報シート
정보 시트
Informační listy




Ordering data
Ordernumber | 175302 |
Item designation | CTP-L1-AP-U-HA-AES-SII-175302 |
Gross weight | 0,kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |