EUCHNER – More than safety.
EUCHNER – More than safety.

Safety switch CET-AR

Benefits for you

  • Safety switch with guard locking and safe guard lock monitoring
  • Integrated CES-AR electronics
  • A special evaluation unit is not required
  • Possible to connect up to 20 devices (CES-AR, CET-AR, MGB-AR,…) in series in an AR chain
  • Safety category 4 and PL e according to EN ISO 13849-1 in any installation orientation, head downward/upward/horizontal
  • Two safe semiconductor outputs and monitoring output OUT
  • Safety outputs with pulsing
  • Input (optional) for the connection of feedback loop and start button

Design and functionality

The CET-AR forms a complete safety solution (PL e according to EN ISO 13849-1). Depending on the version a start button and feedback loop can be connected. As a result the CET-AR includes everything that is necessary to secure a guard. It could not be easier!
Safety switch CET-AR

Connection to safe control systems or safety relays

Do not use a control system or safety relay with pulsing for monitoring short circuits or switch off the pulsing function in these devices. The switch generates its own clock signals on the output lines OA/OB. A downstream device must tolerate these test pulses, which may have a length of up to 1 ms.
The inputs on the downstream device must be suitable for positive-switching devices (pnp outputs), as the two outputs on the safety switch deliver a level of +24 V in the switched-on state.

OUT output

The semiconductor output OUT is switched if the guard is closed (actuator in the actuating range). It is not allowed to be used for safety functions. The OUT outputs on the individual switches can, however, not be polled if connected in series using a Y-distributor. Evaluation is possible only on parallel wiring to the control cabinet.

RST input

The switches in a chain in a fault state can be reset using the RST input. To do this, a voltage of 24 V is applied to the RST input for at least 3 seconds. It is not necessary to disconnect the power supply to reset a fault.

Use as individual switch or switch chain

The safety switch CET-AR can be operated as a compact individual switch or in a switch chain with max. 20 devices.
44023_tiles.jpg
If a single CET-AR is used, connect the device as shown in the figure above. The OUT output can also be connected here to a control system as a monitoring output.
43893_tiles.jpg
The switches are connected in series using plug connectors and Y-distributors. The first switch in the chain must always be fitted with a bridging plug.
If a safety door is opened or if a fault occurs on one of the switches, the system shuts down the machine. A higher-level control system can, however, not detect which safety door is open or on which switch a fault has occurred. A special AR evaluation unit is required.

Product finder

Quick search
Escape release
Ramp
Connection
Wire front release (bowden)

Products (49)

No results found

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com