EUCHNER – More than safety.
EUCHNER – More than safety.

NZ2RS-2131L024GEC2300 (Order no. 106478)

Safety switch NZ.RS, roller plunger, steel roller ø 12 mm, plug connector SM8

  • Version C according to EN 50041 (steel roller ø 12 mm)
  • Plug connector SM8
  • LED indicator
NZ2RS-2131L024GEC2300 (Order no. 106478)

Description

Approach direction

Horizontal

Can be adjusted in 90° steps

Switching element

2131H

Slow-action switching contact 3 NC + 1 NO

Travel diagram
Travel diagram
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
Wiring diagram 2131H
Wiring diagram 2131H
Electromechanical safety switches in use

Functional drawings

Functional drawings
Contacts closed
Contacts open
Contacts positively driven

Dimensional drawings

Dimensional drawings
1Guide lug aligned
2Dog
3Operating point
4Free position
5Right-angle plug connector; default setting for cable outlet right

Connection examples

Connection examples
1WH
2BN
3GN
4YE
5GY
6PK
7BU
8RD
Awithout earth conductor

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20DNV-GL_TAA0000172 Rev. 1DGUV_NZ_ET 23025_ET 23026c_UL_us_E155795_2/4

Electrical connection values

Display module 24 V 10% ... 10%
Rated insulation voltage Ui 30 V
Rated impulse withstand voltage Uimp 1.5 kV
Utilization category
DC-13 1 A 24 V
AC-15 1 A 30 V
Short circuit protection according to IEC 60269-1 1A gG
Switching current
min. at DC 24V 1 mA
thermal rated current Ith 1 A

Mechanical values and environment

Approach speed 0.1 ... 20 m/min
Connection type
1 x Plug connector M12 (8-pin without PE)
Number of NO contacts 1
Number of door position positively driven contacts 3
Actuating element
Slide bearing metal Roller plunger (Steel roller, d roller = 12 mm)
Actuating force 15 ... 30 N
Installation orientation any
Mechanical life 30 x 10⁶
Switching principle Slow-action switching contact
Degree of protection IP67
Ambient temperature -25 ... +80 °C
Material
Contact Silver alloy, gold flashed
Housing Anodized die-cast alloy

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of the guard position2x10720 y


Miscellaneous

C number
C2300
Additional feature Housing without earth conductor! All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN IEC 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent insulation measures.

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 4,7 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 106478
Item designation NZ2RS-2131L024GEC2300
Gross weight 0,346kg
Customs tariff number 85365019000
ECLASS 27-27-26-01 Safety position switch (Type 1)