EUCHNER – More than safety.
EUCHNER – More than safety.

ZSA086681C1979 (Order no. 086681)

ZSA, 3-stage, with LEDs and plug connector MR8

  • Housing G1
  • 3-stage function
  • Plug connector
  • 2 LEDs
  • Actuator for safety switch NZ.VZ or TZ
ZSA086681C1979 (Order no. 086681)

Description

Similar to figure

Switching element

2220

2 NO/NC

LEDs

The LEDs are used for visual feedback direct at the enabling switch.

Actuator

Suitable for safety switch NZ.VZ/TZ (see catalog for safety switches with metal housing). By using an appropriate safety switch as the holder for the enabling switch, the position of the enabling switch can be safely sampled. By suitable integration of this combination, the signal from the safety switch can be used, e.g. as an operating mode selector switch, when the actuator is removed (removal of the enabling switch).

3-stage function

Enabling function is active only in the second stage (center position, actuating point). If the pushbutton is released or pushed further (panic function), the enabling is removed (dependent on the wiring, see function sequence).

Dimension drawing
Dimension drawing
Connector assignment
Connector assignment
Wiring diagram 2220 MR8
Wiring diagram 2220 MR8
Travel diagram
Travel diagram

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples

Shift travel diagrams

Shift travel diagrams
closed, enabling
closed
open

Technical data

Approvals

CCC2020980305002418_CQC2009010305380679_2024EAC_RU C-DE.MO05.B.00972/20c_UL_us_E206093_4/2

Operating and display elements

ItemExtrasColorDesignation1NumberLEDNote slide-in labelSwitching elementSlide-in labelVersion
gnLED
yeLED

Electrical connection values

rated conditional short-circuit current 100 A
Rated insulation voltage Ui 32 V
Rated impulse withstand voltage Uimp 0.8 kV
Utilization category
AC-15 2 A 24 V
DC-13 2 A 24 V
Short circuit protection according to IEC 60269-1 2A gG (In case of operating voltages other than 24 V, the short circuit protection must be dimensioned accordingly and checked.)
Switching voltage
min. at 10 mA 12 V
Switching current
min. at 24 V 1 mA
Switching characteristics 3-stage enabling switch
Degree of contamination (external, according to EN 60947-1) 3
Display/control element
Utilization category
AC-15 Additional elements 400 mA 24 V
DC-13 Additional elements 100 mA 24 V
Short circuit protection according to IEC 60269-1
Additional elements at 24V 0.1A gG (In case of operating voltages other than DC 24 V, the short circuit protection must be dimensioned accordingly and checked.)

Mechanical values and environment

Connection type Plug connector number of pins 8
Number of NO contacts 2
Number of positively driven contacts 2
Mechanical life
Position 1-2-1 0.1 x 10⁶
Position 1-2-3-1 0.1 x 10⁶
Switching principle Slow-action contact element
Degree of protection IP65
Ambient temperature -5 ... +50 °C
Material Plastic

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Enabling switch
B10D 0.5 x 10⁶

Miscellaneous

in compliance with 60947-5-8
Additional feature NZVZ actuator mounted

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 2,0 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 086681
Item designation ZSA086681C1979
Gross weight 0,329kg
Customs tariff number 85365019000
ECLASS 27-37-12-38 Agreement switch