CIA3PL1G08 (Order no. 091875)
Choose content
Read-only interface adapter CIA3PL1G08
- Parallel interface
- In combination with read head CIT3ASX1N12ST
- Rail mounting

Description
Attention:
- The connecting cable to the control system is allowed to be max. 15 m long.
- On the use of a screened cable the connecting cable to the read head is allowed to be max. 15 m long.
- It is only ever possible to connect 1 read head per interface adapter.



Dimensional drawings

1 | Suitable for 35 mm mounting rail according to DIN 46277 |
Connection examples

Connection examples

Technical data
Operating and display elements
LED display | |
yellow | ACTIVE LED data carrier active |
green | STATE LED operational |
Electrical connection values
Connection cross section | 0.14 ... 2.5 mm² |
Output type | Push-pull |
Operating voltage DC | 20 ... 24 ... 28 V DC (All the electrical connections must either be isolated from the mains supply by a safety transformer according to IEC/EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.)) |
Input voltage | |
0 ... 2 V DC Low signal (Reset,Skip) | |
15 ... Ub V DC High signal (Reset,Skip) | |
Switching voltage | |
Ub-3 ... Ub V (High signal (A,B,C,D,Strobe)) | |
0 ... 2 V (Low signal (A,B,C,D,Strobe)) | |
Switching current | |
per output | -30 ... +30 mA |
Current consumption | |
without load | 65 ... 100 mA |
Resistance | 4.5 kΩ For inputs (Reset,Skip) |
Mechanical values and environment
Connection type | plug-in screw terminal |
Number of read heads | max. 1 |
Storage temperature | -25 ... 70 °C |
Mounting type | Mounting rail TH 35 (EN IEC 60715) |
Ambient temperature | 0 ... 55 °C |
Material | |
Housing | PA6.6, gray |
Interface
Date interface | 4-bit binary coded + strobe |
In combination with read head CIT3ASX1N12ST and actuator CIS3AP10D05KH01K, CIS3AP10D05KH01K-P
Read distance | |
0 ... 3 ... 5 mm (for surface mounting of the read head and flush mounting of the data carrier in aluminum) | |
0 ... 3 ... 6 mm (for surface mounting of the read head and flush mounting of the data carrier in ferrous metals) | |
0 ... 3 ... 6.5 mm (for surface mounting of the read head and flush mounting of the data carrier in a non-metallic environment) | |
Center offset | |
at s = 3 mm read distance | -2,5 ... 2,5 mm (for surface mounting of the read head and flush mounting of the data carrier in a non-metallic environment) |
Accessories
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Download Complete Package (ZIP, 0,8 MB)
Single Documents
Declarations of conformity
EU-Konformitätserklärung
Doc. no.
Version
Language
Size

EU-Konformitätserklärung
Doc. no.
EDC2077155
Version
Language
Size
0,2 MB
UKCA-Konformitätserklärung
Doc. no.
Version
Language
Size

UKCA-Konformitätserklärung
Doc. no.
EDC20001517
Version
Language
Size
0,1 MB
Other Documents
Approvals and certificates
WEEE
Doc. no.
Version
Language
Size

WEEE
Doc. no.
ECO20001806
Version
Language
Size
0,1 MB
Ordering data
Ordernumber | 091875 |
Item designation | CIA3PL1G08 |
Gross weight | 0,21kg |
Customs tariff number | 85364110 |
ECLASS | 27-28-04-01 Identification, RFID Reader |