EUCHNER – More than safety.
EUCHNER – More than safety.

MGB-B-A1W2A2-PN-105287 (Order no. 105287)

Bus module MGB-B...-PN... with 3 controls and indicators, push-pull plug

  • 1 cover for indicators
  • 1 operating mode selector
  • 1 illuminated pushbuttons
  • including adhesive labels
  • Push-pull plug
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
MGB-B-A1W2A2-PN-105287 (Order no. 105287)

Description

Profinet connection

Connection via push-pull plugs according to IEC 61076-3-117

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

Dimension drawing
Dimension drawing
MGB: impact test
MGB: mounting door on right, without escape release
MGB: mounting door on left, with escape release
MGB: mounting door on left, without escape release
MGB: in use
MGB: deactivating guard lock monitoring
MGB: pushbutton lens replacement
MGB: activating release monitoring
MGB: activating guard lock monitoring

Dimensional drawings

Dimensional drawings

Technical data

Approvals

TUEV Süd München_M6A 040393 0042 Rev. 00c_UL_us_E155795_3/9ProfiNET_Z10142_Version 2023EAC_RU C-DE.HX37.B.14157/20

Operating and display elements

Occupancy diagram B2
ItemExtrasColorDesignation1NumberLEDNote slide-in labelSlide-in labelVersionSwitching element
11RedCover for indicators
12whiteIlluminated pushbutton1NO
13Entsichert / Unsecured ; Sonderfunktion / Special function ; Gesichert Zentral / Secured CentralOperating mode selectorCode 2 of 3

Electrical connection values

Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X4 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Push-pull power (X2 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Push-pull power (X1 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X3 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Installation orientation any
Switching frequency 0.25 Hz
Response time
Operating mode selector max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
at UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Diagnostic Coverage (DC) 99 %
Mission time 20 y
Category 4
Performance Level PL e
Safety Integrity Level SIL 3 (EN 62061:2005)
Evaluation of multi-position switch
Category 4
Performance Level PL e
PFHD 4.1 x 10-8

Miscellaneous

Slide-in label
NumberLabelingNote
Line Reset
Anlage Gesichert
Quittieren
Line Secured
Product version number V3.23.3

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 6,0 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 105287
Item designation MGB-B-A1W2A2-PN-105287
Gross weight 2,28kg
Customs tariff number 85371098
ECLASS 27-24-26-07 Field bus, decentralized peripheral - basic device

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com