EUCHNER – More than safety.
EUCHNER – More than safety.

MGB-CB-PN-112048 (Order no. 112048)

Control panel MGB-...-PN with 12 control elements, push-pull plug, connection for stack light, RC12

  • Control panel
  • 6 illuminated pushbuttons
  • 6 selector switch, 3-stage, illuminated
  • including adhesive labels
  • Push-pull plug
  • including terminal plug for stack light (M12, 8-pin)
  • including terminal plug for enabling switch (RC12, 12-pin)
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
MGB-CB-PN-112048 (Order no. 112048)

Description

Profinet connection

Connection via push-pull plugs according to IEC 61076-3-117

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

Dimension drawing
Dimension drawing
MGB: impact test
MGB: mounting door on right, without escape release
MGB: mounting door on left, with escape release
MGB: mounting door on left, without escape release
MGB: in use
MGB: deactivating guard lock monitoring
MGB: pushbutton lens replacement
MGB: activating release monitoring
MGB: activating guard lock monitoring

Dimensional drawings

Dimensional drawings

Technical data

Approvals

ProfiNET_Z10387_Version 2023Profisafe_Z20053_Version 2023EAC_RU C-DE.HX37.B.14157/20

Operating and display elements

Occupancy diagram
B1
C1
ItemExtrasColorDesignation1NumberLEDVersionNote slide-in labelSlide-in labelSwitching element
10whiteIlluminated pushbutton1NO
11whiteIlluminated pushbutton1NO
12whiteIlluminated pushbutton1NO
13whiteIlluminated pushbutton1NO
14Selector switch, illuminated2NO
15Selector switch, illuminated2NO
16Selector switch, illuminated2NO
17Selector switch, illuminated2NO
90whiteIlluminated pushbutton1NO
91whiteIlluminated pushbutton1NO
94Selector switch, illuminated2NO
95Selector switch, illuminated2NO

Electrical connection values

Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
Push-pull power (X2 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X4 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Push-pull power (X1 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Plug connector M12 (X6)
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X3 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Plug connector RC12 (X14)
Installation orientation any
Switching frequency 0.25 Hz
Response time
Enabling switch max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
at UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Diagnostic Coverage (DC) 99 %
Mission time 20 y
Category 4
Performance Level PL e
Safety Integrity Level SIL 3 (EN 62061:2005)
Enabling switch
B10D
Enabling switch (Acc. to manufacturer’s specifications)
Enabling switch evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8

Miscellaneous

Slide-in label
NumberLabelingNote
12without marking
Product version number V3.30.10

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 6,5 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 112048
Item designation MGB-CB-PN-112048
Gross weight 3,199kg
Customs tariff number 85371098

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com