MGB-L2CB-PNC-R-114778 (Order no. 114778)

Evaluation module with control and bus module MGB-...-PN with 11 controls and indicators, push-pull plug, RC12

  • Control panel
  • Emergency stop according to ISO 13850
  • 8 illuminated pushbuttons
  • Operating mode selector
  • 1 indicator
  • including adhesive labels
  • Push-pull plug
  • including terminal plug for enabling switch (RC12, 12-pin)
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
MGB-L2CB-PNC-R-114778 (Order no. 114778)

Description

Profinet connection

Connection via push-pull plugs according to IEC 61076-3-117

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings

Technical data

Approvals

TUEV Süd München_M6A 040393 0042 Rev. 00c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20

Workspace

Secured switch-off distance sar
Door position max. 65 mm

Operating and display elements

Occupancy diagram
L2
C3
B2
ItemExtrasColorDesignation1NumberLEDSlide-in labelVersionSwitching elementNote slide-in label
1GreenInicia estaçãoIlluminated pushbutton1NO
11GreenÁrea seguraCover for indicators
12YellowRearma área seguraIlluminated pushbutton1NO
13Destravada ; Travada ; Travada centralOperating mode selectorCode 2 of 3
2RedPara estaçãoIlluminated pushbutton1NO
3GreenLiga água de refrigeraçãoIlluminated pushbutton1NO
4whiteFim de cicloIlluminated pushbutton1NO
5whiteohne AufschriftIlluminated pushbutton1NO
6RedDesliga água de refrigeraçãoIlluminated pushbutton1NO
7Emergency stop2 PD
8whiteLibera porta de segurançaIlluminated pushbutton1NO

Electrical connection values

Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Transponder coding Multicode
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X3 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Push-pull power (X1 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Push-pull power (X2 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Plug connector RC12 (X14)
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X4 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Installation orientation Door hinge DIN right
Switching frequency 0.25 Hz
Mechanical life
1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Response time
Emergency stop / machine stop max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Guard locking max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Door position max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Operating mode selector max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Bolt position max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Enabling switch max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
at UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Safety Integrity Level SIL 3 (EN 62061:2005)
Emergency stop
B10D
Emergency stop 0.13 x 10⁶
Enabling switch
B10D
Enabling switch (Acc. to manufacturer’s specifications)
Emergency-stop evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Enabling switch evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Evaluation of multi-position switch
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Monitoring of guard locking and the guard position
Diagnostic Coverage (DC) 99 %
Category 4
Performance Level PL e
PFHD 4.07 x 10-8 (Fixed failure rate without consideration of faults in wearing parts.)

Miscellaneous

Product version number V3.30.10

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 6,2 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 114778
Item designation MGB-L2CB-PNC-R-114778
Gross weight 4,54kg
Customs tariff number 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking