MBM-PN-S2-MLI-3B-161849 (Order no. 161849)

Bus module MBM-PN... (M12 connection, D-coded, L-coded 5-pin)

  • For connecting MGB2 or MCM modules
  • Connection to PROFINET with PROFIsafe
  • Connection via plug connector M12, D-coded and L-coded (5-pin)
  • Remote or direct mounting
  • Integrated switch
  • Compatible with all Modular devices
MBM-PN-S2-MLI-3B-161849 (Order no. 161849)

Description

PROFINET connection

Plug connector M12, D-coded (M12 plug, L-coded, and M12 plug, D-coded) according to IEC 61076-2-101

PROFINET switch

Linear topology network structure due to integrated switch (supports MRP).

MLI connections (module plug connector)

An MGB2 Modular or an MCM Modular can be connected directly to a bus module (direct plug). Alternatively, the modules can be connected using commercially available connecting cables M12, 5-pin (cable connect).

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
MGB2 Modular: at a glance
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Technical data

Approvals

c_UL_us_E155795_3/9TÜV Süd München_Z10 040393 0028 Rev.04ProfiNET_Z12540

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated insulation voltage Ui 75 V
Rated impulse voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
maximum feed-in current in the connection block
XD1, XD2 max. 16000 mA
Safety class III
Current consumption max. 150 mA
Degree of contamination (external, according to EN 60947-1) 3
Power supply XD1, XD2
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +15% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +15% (The auxiliary voltage is not required for the MGB system)

Mechanical values and environment

Connection type
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12. D-coded, screened (XF1 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.))
M12, L-coded, Power (XD1 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.))
M12, L-coded, Power (XD2 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.))
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12. D-coded, screened (XF2 (The document PROFINET 'Cabling and Interconnection Technology' from the PNO aids in the correct selection of cables.))
Installation orientation any
Storage temperature -25 ... 70 °C
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (In the closed state when the connection cables, connecting cables and submodules are correctly mounted.)
Ambient temperature
at UB = 24 V DC -25 ... 55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
ML1C / ML2C
Connection type Screw terminal
Connection type Male plug
Type specification M12 EN 61076-2-101 / A-coded
Number of pins 5
Insertion cycles 100
ML1D
Connection type Connector (unlocked)
Connection type Male plug
Number of pins 5
Insertion cycles 100

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Evaluating safety signalsPL e33.45x10-9420 y


Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 27,8 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 161849
Item designation MBM-PN-S2-MLI-3B-161849
Gross weight 0,825kg
Customs tariff number 85365019000
ECLASS 27-24-26-07 Field bus, decentralized peripheral - basic device