MBM-PN-S2-MLI-3B-161849 (Order no. 161849)

Bus module MBM-PN... (M12 connection, D-coded, L-coded 5-pin)

  • For connecting MGB2 or MCM modules
  • Connection to PROFINET with PROFIsafe
  • Connection via M12 D-coded and L-coded plug connector(s) (5-pin)
  • Remote or direct mounting
  • Integrated switch
  • Compatible with all Modular devices
MBM-PN-S2-MLI-3B-161849 (Order no. 161849)

Description

PROFINET interface

Plug connector M12, D-coded (M12 plug, L-coded, and M12 plug, D-coded, according to IEC 61076-2-101)

PROFINET switch

Linear topology network structure due to integrated switch (supports MRP).

MLI connections (module plug connector)

An MGB2 Modular or an MCM Modular can be connected directly to a bus module (direct plug). Alternatively, the modules can be connected using commercially available connecting cables M12, 5-pin (cable connect).

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
MGB2 Modular: at a glance
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Technical data

Approvals

Profisafe_Z20197c_UL_us_E155795_3/9ProfiNET_Z12540TÜV Süd München_Z10 040393 0028 Rev.04

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
maximum feed-in current in the connection block
XD1, XD2 max. 16000 mA
Safety class III
Current consumption max. 150 mA
Degree of contamination (external, according to EN 60947-1) 3
Power supply XD1, XD2
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +15% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +15% (The auxiliary voltage is not required for the MGB system)

Mechanical values and environment

Connection type
M12, L-coded, Power (XD1 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12. D-coded, screened (XF1 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
M12, L-coded, Power (XD2 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
according to IEC 61076-2-101, Profinet I/O cable, at least cat. 5e M12. D-coded, screened (XF2 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (Only in closed state with correctly mounted caps and the connecting cables or the connected modules)
Ambient temperature
at UB = 24 V DC -25 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
ML1C / ML2C
Connection type Screw terminal
Connection type Male plug
Type specification M12 EN 61076-2-101 / A-coded
Number of pins 5
Insertion cycles 100
ML1D
Connection type Connector (unlocked)
Connection type Male plug
Number of pins 5
Insertion cycles 100

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Performance Level PL e
PFHD 3.45 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.)
Safety Integrity Level SIL 3 (EN 62061:2005)

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 27,8 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 161849
Item designation MBM-PN-S2-MLI-3B-161849
Gross weight 0,825kg
Customs tariff number 85365019000