EUCHNER – More than safety.
EUCHNER – More than safety.

MGB2-I-MLI-U-Y0000-JJ-157955 (Order no. 157955)

Interlocking module MGB2-I-MLI... (module without blanking covers)

  • Interlocking (without guard locking)
  • Interlocking module MGB2 for connection to a bus module MBM
  • Category 4/PL e for the evaluation of all safety functions
  • Open version (without blanking covers)
  • Adjustable door hinge
  • Unicode
  • Compatible with all Modular devices
MGB2-I-MLI-U-Y0000-JJ-157955 (Order no. 157955)

Description

Guard locking type

MGB2-I...

The bolt tongue in the handle module is moved into and out of the interlocking module by actuating the door handle. The door arm is not locked in the locked position.

Door hinge

On the locking/interlocking modules, the door hinge can be changed from right to left and vice versa at any time with little effort.

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
MGB2 Modular: at a glance
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Technical data

Approvals

TÜV Süd München_Z10 040393 0028 Rev.04FCC_2AJ58-02_

Electrical connection values

Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
Safety class III
Current consumption max. 75 mA
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Switching frequency 0.25 Hz
Mechanical life
1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Response time See operating instructions for bus module MBM-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (This is the case only in the closed state with correctly mounted connecting cables and submodules.)
Ambient temperature
at UB = 24 V DC -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Safety Integrity Level SIL 3 (EN 62061:2005)
Evaluation of safety signals in included submodules
Category 4
Performance Level PL e
PFHD 2.62 x 10-9
Monitoring of the guard position
Diagnostic Coverage (DC) 99 %
Category 4
Performance Level PL e
PFHD 2.62 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.)

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 26,2 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 157955
Item designation MGB2-I-MLI-U-Y0000-JJ-157955
Gross weight 1,01kg
Customs tariff number 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com