EUCHNER – More than safety.
EUCHNER – More than safety.

MGB2-L1-MLI-U-YE1E2-CA-R-162933 (Order no. 162933)

Locking module MGB2-L1-MLI... (4 pushbuttons, emergency stop, closed-circuit current principle, door hinge on right)

  • Guard locking for the protection of persons or processes
  • Locking module MGB2 for connection to a bus module MBM
  • Interlocking with monitored guard locking
  • Category 4/PL e for the evaluation of all safety functions
  • 1 illuminated emergency stop according to ISO 13850
  • 4 illuminated pushbuttons with symbol
  • Adjustable door hinge; factory setting: right
  • Unicode
  • Compatible with all Modular devices
MGB2-L1-MLI-U-YE1E2-CA-R-162933 (Order no. 162933)

Description

Guard locking type

MGB2-L1...

Guard locking by spring force. Release by applying voltage to the guard locking solenoid. (closed-circuit current principle)

Door hinge

On the locking modules, the door stop can be changed from right to left and vice versa at any time with little effort.

Dimension drawing
Dimension drawing
Dimension drawing
Dimension drawing
MGB2 Modular: at a glance
Multifunctional door locking systems

Dimensional drawings

Dimensional drawings

Dimensional drawings

Dimensional drawings

Technical data

Approvals

c_UL_us_E155795_3/9TÜV Süd München_Z10 040393 0028 Rev.04EAC_RU C-DE.HX37.B.14157/20FCC_2AJ58-02_

Mechanical values and environment

Installation orientation Door hinge DIN right

Locking modules MGB2-L1-MLI-U-Y0000-BJ-136776 (Order no. 136776)

Locking modules MGB2-L1-MLI-U-Y0000-BJ-136776  (Order no. 136776)

Electrical connection values

Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements EMC Directive 2014/30/EU
Safety class III
Current consumption max. 350 mA
Transponder coding Unicode
Degree of contamination (external, according to EN 60947-1) 3

Mechanical values and environment

Switching frequency 0.25 Hz
Mechanical life
1 x 10⁶
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
Response time See operating instructions for bus module MBM-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (This is the case only in the closed state with correctly mounted connecting cables and submodules.)
Ambient temperature
at UB = 24 V DC -30 ... +55 °C
Material
Housing Fiber glass reinforced plastic, die-cast zinc, nickel plated
Locking force FZh 2000 N
Guard locking principle Closed-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Safety Integrity Level SIL 3 (EN 62061:2005)
Control of guard locking
Category 4
Performance Level PL e
PFHD 2.62 x 10-9
Evaluation of safety signals in included submodules
Category 4
Performance Level PL e
PFHD 2.62 x 10-9
Monitoring of guard locking and the guard position
Diagnostic Coverage (DC) 99 %
Category 4
Performance Level PL e
PFHD 2.62 x 10-9 (Fixed failure rate without consideration of faults in wearing parts.)

Module connector AC-MC-SB-M-A-157024 (Order no. 157024)

Module connector AC-MC-SB-M-A-157024  (Order no. 157024)

Electrical connection values

Connecting cable
MLI 5-pin, M12x1
Rated voltage 36 V
Rated voltage 30 V
Nominal current
at 40 °C 4 A
Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Connection 1
Connection type 2x M4 screws
Connection type Male plug
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic
Connection 2
Connection type Screw terminal
Connection type Male plug
Type specification M12 EN 61076-2-101 / A-coded
Number of pins 5
Degree of protection IP65 (Only in the screwed tight state with the related mating components.)
Insertion cycles 100
Material
Plug housing Plastic, die-cast zinc, nickel plated
Plug lock die-cast zinc, nickel plated

Submodules MSM-1-P-CA-PP0-E1-162927 (Order no. 162927)

Submodules MSM-1-P-CA-PP0-E1-162927  (Order no. 162927)

Operating and display elements

ItemExtrasColorDesignation1NumberLEDVersionNote slide-in labelSwitching elementSlide-in label
1printedwhiteIlluminated pushbutton1NO
2printedwhiteIlluminated pushbutton1NO

Electrical connection values

Current consumption max. 20 mA
Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage 24 V
Switching current 5 ... 10 mA
LED power supply 24 V DC

Mechanical values and environment

Installation orientation any
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (IP65: only in the screwed tight state with the specified base units.)
Ambient temperature
at UB = 24 V DC -25 ... +55 °C
Material Fiber glass reinforced plastic

Miscellaneous

Software ID (SW ID) 9000002

Submodules MSM-1-P-CA-BPP-E2-162930 (Order no. 162930)

Submodules MSM-1-P-CA-BPP-E2-162930  (Order no. 162930)

Operating and display elements

ItemExtrasColorDesignation1NumberLEDVersionNote slide-in labelSwitching elementSlide-in label
1Illuminated emergency stop2 PD
2printedBlueIlluminated pushbutton1NO
3printedtranslucent blueIlluminated pushbutton1NO

Electrical connection values

Current consumption max. 32 mA
Controls and indicators
Breaking capacity max. 0.25 W
Switching voltage 24 V
Switching current 5 ... 10 mA
LED power supply 24 V DC
Illuminated emergency stop
Breaking capacity max. 0.25 W
Switching voltage 5 ... 24 V
Switching current 5 ... 100 mA
LED power supply 24 V DC

Mechanical values and environment

Installation orientation any
Response time See operating instructions for bus module MBM-... or interlocking/locking module MGB2-I.-BR-... / MGB2-L.-BR-...
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (IP20) (IP65: only in the screwed tight state with the specified base units.)
Ambient temperature
at UB = 24 V DC -25 ... +55 °C
Material Fiber glass reinforced plastic

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Illuminated emergency stop
B10D
Emergency stop 0.13 x 10⁶

Miscellaneous

Software ID (SW ID) 9000001

AC-MC-00-0-B-156718 (Order no. 156718)

AC-MC-00-0-B-156718  (Order no. 156718)

Electrical connection values

Degree of contamination according to EN 60664-1 3

Mechanical values and environment

Ambient temperature -30 ... +55 °C
Material Fiber glass reinforced plastic
Connection 1
Connection type 2x M4 screws
Degree of protection IP65 (Only in the screwed tight state with the specified base units.)

Miscellaneous

Color black
Additional feature
incl. seal
incl. fixing screws

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 26,8 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 162933
Item designation MGB2-L1-MLI-U-YE1E2-CA-R-162933
Gross weight 1,4kg
Customs tariff number 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk