CES-I-AR-U-C04-SG-EX-175319 (Order no. 175319)
Safety switch CES-I-AR-.-C04-..., ATEX, RFID, plug connector(s) M8
- ATEX version
- Unicode
- Monitoring output door position OD
- Plug connector M8, 8-pin

Description
Version ATEX
Suitable for use in zones 2 and 22 (gases and dusts).
Application area II 3G D.
Housing guard
The Housing guard included in the scope of delivery protects the safety switch against impacts on the housing and the plug connector(s). The Housing guard must be fitted in order to achieve the specified explosion protection.
Unicode evaluation
Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.
Only the last actuator taught-in is detected.
Safety characteristics
Thanks to two redundant safety outputs (semiconductor outputs) with internal monitoring, the device is suitable for:
- Category 4 /PL e according to EN 13849-1
- SIL 3 according to EN IEC 62061 Table 4
The OSSD outputs used check their function for short circuits and short circuits with test pulses.
LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Terminal assignment
Scope of delivery
- Housing guard
- Rubber pad
Accessories required
Actuator is not included.


Dimensional drawings

Connection examples

Technical data
Approvals


Workspace
Repeat accuracy R | |
according to EN 60947-5-2 | <= 10 |
Electrical connection values
Fuse | |
external (operating voltage) | 0.25 ... 8 A |
Rated insulation voltage Ui | 30 V |
Rated impulse voltage Uimp | 0.5 kV |
Operating voltage DC | |
UB | 24 V DC -15% ... +15% regulated, residual ripple<5%, PELV |
Turn-on time | |
Safety outputs | max. 400 ms |
EMC protection requirements | Acc. to EN IEC 60947-5-3 |
Risk time according to EN 60947-5-3 | max. 260 ms |
Risk time according to EN 60947-5-3, extension for each additional device | max. 5 ms |
Safety class | III |
Current consumption | max. 35 mA (without taking into account the load currents on the monitoring output and the safety outputs) |
Degree of contamination (external, according to EN 60947-1) | 3 |
Monitoring output OD | |
Output type | Semiconductor output, p-switching, short circuit-proof |
Output voltage | 0.8 x UB ... UB V DC |
Switching current | max. 50 mA |
Safety outputs FO1A/FO1B | |
Output type | Semiconductor outputs, p-switching, short circuit-proof |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.) |
rated conditional short-circuit current | 100 A |
Discrepancy time | max. 10 ms |
Utilization category | |
DC-13 | 24V 200mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.) |
Off-state current Ir | max. 0.25 mA |
Switching current | |
per safety output | 1 ... 200 mA |
Test pulse duration | max. 1.0 ms (Applies to a load with C<= 30nF and R<= 20kOhm) |
Test pulse interval | min. 140 ms |
Mechanical values and environment
Connection type | M8 plug connector, 8-pin |
Tightening torque | |
Fixing screws | max. 0.6 Nm |
Ready delay | 10 s |
Installation orientation | any |
Switching frequency | max. 1 Hz |
Mounting distance | |
between switches | min. 80 mm |
Mounting type | Surface mounting on metal |
Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
Degree of protection | IP67/IP69K (only version with M8 plug connector and mating connector with the same degree of protection) |
Ambient temperature | -25 ... 65 °C |
Material | |
Rubber support | NBR 80 ±5 Shore |
Housing | Plastic, PBT |
Housing guard | Fiber glass reinforced plastic |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
PL | Maximum SIL | PFHD | Category | Mission time | |
---|---|---|---|---|---|
Monitoring of the guard position | PL e | - | 4.1x10-9 | 4 | 20 y |
Miscellaneous
Explosion protection in accordance with ATEX Directive 2024/34/EU | II 3 G Ex ic ec IIB T5 Gc X / II 3 D Ex ic tc IIIC T90°C Dc X |
Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures |
Additional feature | Housing guard and rubber pad included in the scope of delivery |
In combination with actuator CES-A-BBN-C04-EX-137527
Switch-on distance | |
Installation position A or B (front side) | 15 mm |
Installation position C or D (broad side) | 11 mm |
Secured switch-off distance sar | |
in x/z direction | max. 40 mm |
in y direction | max. 60 mm |
Secured switching distance sao | |
Installation position A or B (front side) | 10 mm |
Installation position C or D (broad side) | 6 mm |
Switching hysteresis | 1 ... 2 mm |
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents




Other Documents






Ordering data
Ordernumber | 175319 |
Item designation | CES-I-AR-U-C04-SG-EX-175319 |
Gross weight | 0,111kg |
Customs tariff number | 85365019000 |
ECLASS | 27-27-24-03 Safety-related transponder switch |