Safety switch CET-AR
Benefits for you
- Safety switch with guard locking and safe guard lock monitoring
- Integrated CES-AR electronics
- A special evaluation unit is not required
- Possible to connect up to 20 devices (CES-AR, CET-AR, MGB-AR,…) in series in an AR chain
- Safety category 4 and PL e according to EN ISO 13849-1 in any installation orientation, head downward/upward/horizontal
- Two safe semiconductor outputs and monitoring output OUT
- Safety outputs with pulsing
- Input (optional) for the connection of feedback loop and start button
Design and functionality
The CET-AR forms a complete safety solution (PL e according to EN ISO 13849-1). Depending on the version a start button and feedback loop can be connected. As a result the CET-AR includes everything that is necessary to secure a guard. It could not be easier!
Connection to safe control systems or safety relays
Do not use a control system or safety relay with pulsing for monitoring short circuits or switch off the pulsing function in these devices. The switch generates its own clock signals on the output lines OA/OB. A downstream device must tolerate these test pulses, which may have a length of up to 1 ms.The inputs on the downstream device must be suitable for positive-switching devices (pnp outputs), as the two outputs on the safety switch deliver a level of +24 V in the switched-on state.
OUT output
The semiconductor output OUT is switched if the guard is closed (actuator in the actuating range). It is not allowed to be used for safety functions. The OUT outputs on the individual switches can, however, not be polled if connected in series using a Y-distributor. Evaluation is possible only on parallel wiring to the control cabinet.RST input
The switches in a chain in a fault state can be reset using the RST input. To do this, a voltage of 24 V is applied to the RST input for at least 3 seconds. It is not necessary to disconnect the power supply to reset a fault.Use as individual switch or switch chain
The safety switch CET-AR can be operated as a compact individual switch or in a switch chain with max. 20 devices.
If a single CET-AR is used, connect the device as shown in the figure above. The OUT output can also be connected here to a control system as a monitoring output.

The switches are connected in series using plug connectors and Y-distributors. The first switch in the chain must always be fitted with a bridging plug.
If a safety door is opened or if a fault occurs on one of the switches, the system shuts down the machine. A higher-level control system can, however, not detect which safety door is open or on which switch a fault has occurred. A special AR evaluation unit is required.
Product finder
Products (49)
No results found

106275
CET1-AR-CDA-AH-50X-SG-106275
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, double ramp
CET1-AR-CDA-AH-50X-SG-106275
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, double ramp
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Double ramp

109231
CET1-AR-CDA-CH-50X-SG-109231
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, double ramp
CET1-AR-CDA-CH-50X-SG-109231
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, double ramp
- Closed-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Double ramp

113255
CET1-AR-CDA-CH-50X-SH-113255
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18), double ramp
CET1-AR-CDA-CH-50X-SH-113255
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18), double ramp
- Closed-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- Plug connector(s) M23 (RC18), 19-pole
- Double ramp

106616
CET1-AR-CRA-AH-50A-SG-106616
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
CET1-AR-CRA-AH-50A-SG-106616
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
- Closed-circuit current principle
- Unicode
- Feedback loop Y
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Escape release, 75 mm long

106159
CET1-AR-CRA-AH-50F-SG-106159
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
CET1-AR-CRA-AH-50F-SG-106159
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Escape release, 75 mm long

110943
CET1-AR-CRA-AH-50F-SH-C2312-110943
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18), escape release
CET1-AR-CRA-AH-50F-SH-C2312-110943
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18), escape release
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Plug connector(s) M23 (RC18), 19-pole
- Escape release, 105 mm long

105802
CET1-AR-CRA-AH-50S-SG-105802
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET1-AR-CRA-AH-50S-SG-105802
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Closed-circuit current principle
- Unicode
- Feedback loop Y
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin

103418
CET1-AR-CRA-AH-50X-SG-103418
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET1-AR-CRA-AH-50X-SG-103418
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Closed-circuit current principle
- Unicode
- Monitoring output guard locking OUT
- Teach-in input J
- 2 x plug connector(s) M12, 5-pin and 8-pin

110203
CET1-AR-CRA-AH-50X-SH-110203
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
CET1-AR-CRA-AH-50X-SH-110203
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Plug connector(s) M23 (RC18), 19-pole

113022
CET1-AR-CRA-AH-50X-SH-C2290-113022
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18), wire front release (bowden)
CET1-AR-CRA-AH-50X-SH-C2290-113022
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18), wire front release (bowden)
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Plug connector(s) M23 (RC18), 19-pole
- Wire front release (bowden), 3 m, automatic return

110241
CET1-AR-CRA-CH-50F-SG-110241
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
CET1-AR-CRA-CH-50F-SG-110241
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
- Closed-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Escape release, 75 mm long

124104
CET1-AR-CRA-CH-50F-SH-C2312-124104
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
CET1-AR-CRA-CH-50F-SH-C2312-124104
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
- Closed-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- Plug connector(s) M23 (RC18), 19-pole
- Escape release, 105 long

105764
CET1-AR-CRA-CH-50S-SG-105764
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET1-AR-CRA-CH-50S-SG-105764
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Closed-circuit current principle
- Multicode
- Feedback loop Y
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin

105763
CET1-AR-CRA-CH-50X-SG-105763
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET1-AR-CRA-CH-50X-SG-105763
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Closed-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin

109015
CET1-AR-CRA-CH-50X-SG-C2290-109015
Safety switch with guard locking CET-AR-..., RFID, plug connector M12, wire front release (bowden)
CET1-AR-CRA-CH-50X-SG-C2290-109015
Safety switch with guard locking CET-AR-..., RFID, plug connector M12, wire front release (bowden)
- Closed-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Wire front release (bowden), 3 m, automatic return

110204
CET1-AR-CRA-CH-50X-SH-110204
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
CET1-AR-CRA-CH-50X-SH-110204
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
- Closed-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- Plug connector(s) MR23 (RC18), 19-pole

109075
CET2-AR-CRA-AH-50S-SG-109075
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET2-AR-CRA-AH-50S-SG-109075
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Open-circuit current principle
- Unicode
- Feedback loop Y
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin

110240
CET2-AR-CRA-AH-50X-SG-110240
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET2-AR-CRA-AH-50X-SG-110240
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Open-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin

110205
CET2-AR-CRA-AH-50X-SH-110205
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
CET2-AR-CRA-AH-50X-SH-110205
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
- Open-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Plug connector(s) M23 (RC18), 19-pole

109941
CET2-AR-CRA-CH-50F-SG-C2312-109941
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
CET2-AR-CRA-CH-50F-SG-C2312-109941
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
- Open-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Escape release, 105 mm long

110082
CET2-AR-CRA-CH-50X-SG-110082
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET2-AR-CRA-CH-50X-SG-110082
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Open-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- 2 x plug connector(s) M12, 5-pin and 8-pin

110206
CET2-AR-CRA-CH-50X-SH-110206
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
CET2-AR-CRA-CH-50X-SH-110206
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
- Open-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- Plug connector(s) M23 (RC18), 19-pole

114090
CET3-AR-CDA-CH-50X-SG-114090
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, double ramp
CET3-AR-CDA-CH-50X-SG-114090
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, double ramp
- Closed-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Double ramp

113965
CET3-AR-CRA-AH-50F-SG-113965
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
CET3-AR-CRA-AH-50F-SG-113965
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Escape release, 75 mm long

113148
CET3-AR-CRA-AH-50F-SH-113148
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18), escape release
CET3-AR-CRA-AH-50F-SH-113148
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18), escape release
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- Plug connector(s) M23 (RC18), 19-pole
- Escape release, 75 mm long

111725
CET3-AR-CRA-AH-50F-SH-C2312-111725
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18), escape release
CET3-AR-CRA-AH-50F-SH-C2312-111725
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18), escape release
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- Plug connector(s) M23 (RC18), 19-pole
- Escape release, 105 mm long

113023
CET3-AR-CRA-AH-50F-SH-C2353-113023
Safety switch with guard locking CET-AR-..., RFID, plug connector M23 (RC18), wire front release (bowden), escape release
CET3-AR-CRA-AH-50F-SH-C2353-113023
Safety switch with guard locking CET-AR-..., RFID, plug connector M23 (RC18), wire front release (bowden), escape release
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- Plug connector(s) M23 (RC18), 19-pole
- Wire front release (bowden), 3 m, automatic return
- Escape release, 105 mm long

109401
CET3-AR-CRA-AH-50X-SG-109401
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET3-AR-CRA-AH-50X-SG-109401
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Closed-circuit current principle
- Unicode
- Monitoring output door position OUT D
- Monitoring output guard locking OUT
- Teach-in input J
- 2 x plug connector(s) M12, 5-pin and 8-pin

113139
CET3-AR-CRA-AH-50X-SG-C2290-113139
Safety switch with guard locking CET-AR-..., RFID, plug connector M12, wire front release (bowden)
CET3-AR-CRA-AH-50X-SG-C2290-113139
Safety switch with guard locking CET-AR-..., RFID, plug connector M12, wire front release (bowden)
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Wire front release (bowden), 3 m, automatic return

110103
CET3-AR-CRA-AH-50X-SH-110103
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
CET3-AR-CRA-AH-50X-SH-110103
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- Plug connector(s) M23 (RC18), 19-pole

113024
CET3-AR-CRA-AH-50X-SH-C2290-113024
Safety switch with guard locking CET-AR-..., RFID; plug connector M23 (RC18), wire front release (bowden)
CET3-AR-CRA-AH-50X-SH-C2290-113024
Safety switch with guard locking CET-AR-..., RFID; plug connector M23 (RC18), wire front release (bowden)
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- Plug connector(s) M23 (RC18), 19-pole
- Wire front release (bowden), 3 m, automatic return

114088
CET3-AR-CRA-AH-50X-SH-C2290-114088
Safety switch with guard locking CET-AR-..., plug connector(s) M23 (RC18), wire front release (bowden)
CET3-AR-CRA-AH-50X-SH-C2290-114088
Safety switch with guard locking CET-AR-..., plug connector(s) M23 (RC18), wire front release (bowden)
- Closed-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- Plug connector(s) M23 (RC18), 19-pole
- Wire front release (bowden), 5 m, automatic return

115202
CET3-AR-CRA-AH-50X-SH-C2375-115202
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
CET3-AR-CRA-AH-50X-SH-C2375-115202
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
- Closed-circuit current principle
- Unicode
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- Plug connector(s) M23 (RC18), 19-pole

110907
CET3-AR-CRA-CH-50F-SG-110907
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
CET3-AR-CRA-CH-50F-SG-110907
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
- Closed-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Escape release, 75 mm long

112992
CET3-AR-CRA-CH-50S-SG-112992
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET3-AR-CRA-CH-50S-SG-112992
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Closed-circuit current principle
- Multicode
- Feedback loop Y / start button
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin

110906
CET3-AR-CRA-CH-50X-SG-110906
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET3-AR-CRA-CH-50X-SG-110906
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Closed-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin

110114
CET3-AR-CRA-CH-50X-SG-C2290-110114
Safety switch with guard locking CET-AR-..., RFID, plug connector M12, wire front release (bowden)
CET3-AR-CRA-CH-50X-SG-C2290-110114
Safety switch with guard locking CET-AR-..., RFID, plug connector M12, wire front release (bowden)
- Closed-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Wire front release (bowden), 3 m, automatic return

110104
CET3-AR-CRA-CH-50X-SH-110104
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
CET3-AR-CRA-CH-50X-SH-110104
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
- Closed-circuit current principle
- Multicode
- Monitoring output door position OUT D
- Monitoring output guard locking OUT
- Plug connector(s) M23 (RC18), 19-pole

114712
CET4-AR-CDA-CH-50X-SG-114712
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, double ramp
CET4-AR-CDA-CH-50X-SG-114712
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, double ramp
- Open-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Double ramp

116285
CET4-AR-CRA-AH-50F-SH-116285
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18), escape release
CET4-AR-CRA-AH-50F-SH-116285
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18), escape release
- Open-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- Plug connector(s) M23 (RC18), 19-pole
- Escape release, 75 mm long

111683
CET4-AR-CRA-AH-50X-SG-111683
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET4-AR-CRA-AH-50X-SG-111683
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Open-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin

128193
CET4-AR-CRA-AH-50X-SG-C2290-128193
Safety switch with guard locking CET-AR-..., RFID, plug connector M12, wire front release (bowden)
CET4-AR-CRA-AH-50X-SG-C2290-128193
Safety switch with guard locking CET-AR-..., RFID, plug connector M12, wire front release (bowden)
- Open-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Wire front release (bowden), 3 m

162555
CET4-AR-CRA-AH-50X-SG-C2355-162555
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET4-AR-CRA-AH-50X-SG-C2355-162555
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Open-circuit current principle
- Unicode
- 2 x monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin

110201
CET4-AR-CRA-AH-50X-SH-110201
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
CET4-AR-CRA-AH-50X-SH-110201
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
- Open-circuit current principle
- Unicode
- Teach-in input J
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- Plug connector(s) M23 (RC18), 19-pole

114650
CET4-AR-CRA-CH-50F-SG-114650
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
CET4-AR-CRA-CH-50F-SG-114650
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12, escape release
- Open-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Escape release, 75 mm long

113081
CET4-AR-CRA-CH-50S-SG-113081
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET4-AR-CRA-CH-50S-SG-113081
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Open-circuit current principle
- Multicode
- Feedback loop Y / start button
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin

111684
CET4-AR-CRA-CH-50X-SG-111684
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET4-AR-CRA-CH-50X-SG-111684
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Open-circuit current principle
- Multicode
- Monitoring output guard locking OUT
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin

113609
CET4-AR-CRA-CH-50X-SG-C2355-113609
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
CET4-AR-CRA-CH-50X-SG-C2355-113609
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M12
- Open-circuit current principle
- Multicode
- 2 x monitoring output guard locking
- Monitoring output door position OUT D
- 2 x plug connector(s) M12, 5-pin and 8-pin

110202
CET4-AR-CRA-CH-50X-SH-110202
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
CET4-AR-CRA-CH-50X-SH-110202
Safety switch with guard locking CET-AR-..., RFID, plug connector(s) M23 (RC18)
- Open-circuit current principle
- Multicode
- Monitoring output door position OUT D
- Monitoring output guard locking OUT
- Plug connector(s) M23 (RC18), 19-pole