Safety switch CTP-AR
Benefits for you
- Safety switch with guard locking and safe guard lock monitoring
- Integrated CES-AR electronics
- A special evaluation unit is not required
- Up to 20 AR devices can be connected in series in a chain
- Safety category 4 and PL e according to EN ISO 13849-1
- Mounting compatible with existing safety switches
Thanks to the transponder technology, even a single CTP achieves category 4/PL e according to EN ISO 13849-1, without additional fault exclusion, and meets all the requirements of EN ISO 14119. It is ideally suited to applications in which a high Performance Level and a locking force of up to 3,900 N are required
Versatile in use
The CTP reliably secures safety doors and flaps on machines and systems. Thanks to the integrated guard locking and guard lock monitoring, it can be used both for process protection and the protection of personnel. Its compact design permits space-saving mounting on the guard.With a guard locking force of 3,900 N the CTP effectively prevents the opening of safety doors. The very robust plastic housing with metal head as well as the high degree of protection IP67/IP69/IP69K make the CTP the all-rounder for almost every industrial use. The CTP is suitable even for harsh, dirty environments.
Mounting and principle of operation
The CTP consists of two components, a safety switch and a separate actuator. The safety switch is mounted on the fixed part of the guard, the actuator on the movable part.The CTP can be approached from four directions. For improved insertion of the actuator, the head is equipped with an integrated funnel. This feature is particularly advantageous on unstable door designs as well as if the door is incorrectly adjusted.
When the guard is closed, the actuator moves into the head on the safety switch. The safety outputs are switched on if the integrated transponder chip in the actuator is detected and the guard locking activated.
Thanks to the integrated prevention of inadvertent locking position (faulty closure protection), unintentional activation of the safety outputs is prevented if the actuator is not completely inserted into the head.
System family AR
In the AR version up to 20 safety switches CTP or other EUCHNER products that belong to the AR system family can be connected in series. 2 different wiring concepts are available:Series connection in the control cabinet:
Wiring takes place in the control cabinet. All information about the status of individual CTPs can be forwarded directly to the control system.
Series connection in the field:
For field wiring EUCHNER offers the option of using M12 plugs and Y-pieces to connect together several CTPs.
Instead of the Y-plug connectors, it is also possible to use a passive distribution module. On this device, all safety and status signals are collected together in the field and forwarded to the control system using one cable.
Products (19)
No results found
123308
CTP-L1-AR-M-HA-AE-SAB-123308
Safety switch with guard locking CTP-AR, RFID, plug connector M12, escape release
CTP-L1-AR-M-HA-AE-SAB-123308
Safety switch with guard locking CTP-AR, RFID, plug connector M12, escape release
- Closed-circuit current principle
- Multicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Guard lock monitoring output OL
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Escape release
123374
CTP-L1-AR-M-HA-AE-SH-123374
Safety switch with guard locking CTP-AR, RFID, plug connector M23, escape release
CTP-L1-AR-M-HA-AE-SH-123374
Safety switch with guard locking CTP-AR, RFID, plug connector M23, escape release
- Closed-circuit current principle
- Multicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Guard lock monitoring output OL
- Plug connector(s) M23 (RC18), 19-pole
- Escape release
123307
CTP-L1-AR-M-HA-AZ-SAB-123307
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M12
CTP-L1-AR-M-HA-AZ-SAB-123307
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M12
- Closed-circuit current principle
- Multicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Guard lock monitoring output OL
- 2 x plug connector(s) M12, 5-pin and 8-pin
123363
CTP-L1-AR-M-HA-AZ-SH-123363
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M23 (RC18)
CTP-L1-AR-M-HA-AZ-SH-123363
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M23 (RC18)
- Closed-circuit current principle
- Multicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Guard lock monitoring output OL
- Plug connector(s) M23 (RC18), 19-pole
157816
CTP-L1-AR-M-HA-AZS-SAB-157816
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M12, stainless steel
CTP-L1-AR-M-HA-AZS-SAB-157816
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M12, stainless steel
- Closed-circuit current principle
- Multicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Guard lock monitoring output OL
- 2 x plug connector(s) M12, 5-pin and 8-pin
- ECOLAB certificate
- Version with stainless-steel components
122813
CTP-L1-AR-U-HA-AE-SAB-122813
Safety switch with guard locking CTP-AR, RFID, plug connector M12, escape release
CTP-L1-AR-U-HA-AE-SAB-122813
Safety switch with guard locking CTP-AR, RFID, plug connector M12, escape release
- Closed-circuit current principle
- Unicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Guard lock monitoring output OL
- 2 x plug connector(s) M12, 5-pin and 8-pin
- Escape release
123373
CTP-L1-AR-U-HA-AE-SH-123373
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M23 (RC18), escape release
CTP-L1-AR-U-HA-AE-SH-123373
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M23 (RC18), escape release
- Closed-circuit current principle
- Unicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Guard lock monitoring output OL
- Plug connector(s) M23 (RC18), 19-pole
- Escape release
137164
CTP-L1-AR-U-HA-AEE-SH-137164
Safety switch with guard locking CTP-AR EXTENDED, RFID, plug connector M23 (RC18), EMERGENCY STOP, escape release
CTP-L1-AR-U-HA-AEE-SH-137164
Safety switch with guard locking CTP-AR EXTENDED, RFID, plug connector M23 (RC18), EMERGENCY STOP, escape release
- Extended (2 illuminated pushbuttons, EMERGENCY STOP)
- Closed-circuit current principle
- Unicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Plug connector(s) M23 (RC18), 19-pole
- Escape release
122812
CTP-L1-AR-U-HA-AZ-SAB-122812
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M12
CTP-L1-AR-U-HA-AZ-SAB-122812
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M12
- Closed-circuit current principle
- Unicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Guard lock monitoring output OL
- 2 x plug connector(s) M12, 5-pin and 8-pin
123362
CTP-L1-AR-U-HA-AZ-SH-123362
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M23 (RC18)
CTP-L1-AR-U-HA-AZ-SH-123362
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M23 (RC18)
- Closed-circuit current principle
- Unicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Guard lock monitoring output OL
- Plug connector(s) M23 (RC18), 19-pole
126874
CTP-L1-AR-U-HA-AZE-SH-126874
Safety switch with guard locking CTP-AR EXTENDED, RFID, plug connector(s) M23 (RC18), EMERGENCY STOP
CTP-L1-AR-U-HA-AZE-SH-126874
Safety switch with guard locking CTP-AR EXTENDED, RFID, plug connector(s) M23 (RC18), EMERGENCY STOP
- Extended (2 illuminated pushbuttons, EMERGENCY STOP)
- Closed-circuit current principle
- Unicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Plug connector(s) M23 (RC18), 19-pole
137341
CTP-L1-AR-U-HA-AZE-SH-137341
Safety switch with guard locking CTP-AR EXTENDED, RFID, plug connector(s) M23 (RC18)
CTP-L1-AR-U-HA-AZE-SH-137341
Safety switch with guard locking CTP-AR EXTENDED, RFID, plug connector(s) M23 (RC18)
- Extended (2 illuminated pushbuttons)
- Closed-circuit current principle
- Unicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Guard lock monitoring output OL
- Plug connector(s) M23 (RC18), 19-pole
160862
CTP-L1-AR-U-HA-AZS-SAB-160862
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M12, stainless steel
CTP-L1-AR-U-HA-AZS-SAB-160862
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M12, stainless steel
- Closed-circuit current principle
- Unicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Guard lock monitoring output OL
- 2 x plug connector(s) M12, 5-pin and 8-pin
- ECOLAB certificate
- Version with stainless-steel components
123361
CTP-L2-AR-M-HA-AZ-SAB-123361
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M12
CTP-L2-AR-M-HA-AZ-SAB-123361
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M12
- Open-circuit current principle
- Multicode
- Guard lock monitoring output OL
- Monitoring output door position OD
- Monitoring output diagnosis OI
- 2 x plug connector(s) M12, 5-pin and 8-pin
123369
CTP-L2-AR-M-HA-AZ-SH-123369
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M23 (RC18)
CTP-L2-AR-M-HA-AZ-SH-123369
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M23 (RC18)
- Open-circuit current principle
- Multicode
- Guard lock monitoring output OL
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Plug connector(s) M23 (RC18), 19-pole
159112
CTP-L2-AR-U-HA-AEE-SH-159112
Safety switch with guard locking CTP-AR EXTENDED, RFID, plug connector(s) M23 (RC18), escape release
CTP-L2-AR-U-HA-AEE-SH-159112
Safety switch with guard locking CTP-AR EXTENDED, RFID, plug connector(s) M23 (RC18), escape release
- Extended (2 illuminated pushbuttons, EMERGENCY STOP)
- Open-circuit current principle
- Unicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Plug connector(s) M23 (RC18), 19-pole
- Escape release
122814
CTP-L2-AR-U-HA-AZ-SAB-122814
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M12
CTP-L2-AR-U-HA-AZ-SAB-122814
Safety switch with guard locking CTP-AR, RFID, plug connector(s) M12
- Open-circuit current principle
- Unicode
- Guard lock monitoring output OL
- Monitoring output door position OD
- Monitoring output diagnosis OI
- 2 x plug connector(s) M12, 5-pin and 8-pin
123366
CTP-L2-AR-U-HA-AZ-SH-123366
Transponder-coded safety switch CTP-AR, M23
CTP-L2-AR-U-HA-AZ-SH-123366
Transponder-coded safety switch CTP-AR, M23
- Safety switch with guard locking and integrated evaluation electronics
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1
- With plug connector M23
- Unicode
- Door monitoring output
- Approach directions A, B and C (delivery state)
137165
CTP-L2-AR-U-HA-AZE-SH-137165
Safety switch with guard locking CTP-AR EXTENDED, RFID, plug connector(s) M23 (RC18)
CTP-L2-AR-U-HA-AZE-SH-137165
Safety switch with guard locking CTP-AR EXTENDED, RFID, plug connector(s) M23 (RC18)
- Extended (2 illuminated pushbuttons, EMERGENCY STOP)
- Open-circuit current principle
- Unicode
- Monitoring output door position OD
- Monitoring output diagnosis OI
- Plug connector(s) M23 (RC18), 19-pole