CTM-C2-BP-HC-FLX-AZ-SA-170491 (Order no. 170491)
Safety switch with guard locking CTM-C2-BP FlexFunction, RFID, plug connector(s) M12
- FlexFunction
- Open-circuit current principle
- Guard locking for process protection
- Highly coded
- Guard lock monitoring output OL
- Monitoring output diagnosis OI
- Door position monitoring output/communication OD/C
- Plug connector M12, 8-pin
- Actuating/extraction/retention force: 20/18/5 N
- Auxiliary release

Description
Guard locking principle
Open-circuit current (power on to lock): On a guard with guard locking based on the open-circuit current principle, the guard is locked until the power supply to the guard locking solenoid is interrupted. Unlocking is by spring force. The term electrical guard locking is also used.
Guard locking for process protection
The safety switch meets the requirements for interlocking devices with guard locking for process protection. It does not possess safe guard lock monitoring.
Highly coded evaluation
Each actuator is highly coded. The switch only recognizes learned actuators. Further actuators can be taught.
Only the last actuator taught-in is detected.
Auxiliary release
The auxiliary release on the front allows access to the machine in the event of a malfunction, e.g. a power failure.
Terminal assignment
Accessories required
Actuator is not included.


Dimensional drawings

| 1 | LEDs |
| 2 | Active read head face |
| 3 | Auxiliary release |
Connection examples

Technical data
Approvals


Workspace
| Repeat accuracy R | 10 % |
Electrical connection values
| Fuse | |
| external (operating voltage UB) | 0.7 ... 8 A |
| Power consumption | |
| at max. switching frequency | 3 W |
| Rated insulation voltage Ui | 50 V |
| Rated impulse voltage Uimp | 0.5 kV |
| Discrepancy time | |
| both safety outputs | max. 10 ms Acc. to EN IEC 60947-5-3 |
| Turn-on time | max. 500 ms / 100 ms without guard lock monitoring |
| Solenoid duty cycle | 100 % |
| Off-state current Ir | max. 0.25 mA |
| Risk time according to EN 60947-5-3 | max. 200 ms |
| Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
| Switching load | DC 24V, UL Class 2 (alternatively, see operating instructions) |
| Safety class | III |
| Test pulse duration | max. 0.3 ms |
| Test pulse interval | 100 ms |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Solenoid IMP | |
| Input voltage | |
| Guard locking active (closed) | 20.4 ... 26.4 V DC |
| Guard locking not active (open) | 0 ... 5 V DC |
| Current consumption | |
| Guard locking active (closed) | 20 ... 50 mA |
| Diagnostic monitoring output OI, door position monitoring output/communication OD/C, guard lock monitoring output OL | |
| Output type | p-switching, short circuit-proof |
| Output voltage | 0.8xUB ... UB V DC |
| Switching current | 1 ... 50 mA |
| Safety outputs FO1A/FO1B | |
| Output type | 2 semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
| HIGH U(FO1A) / U(FO1B) | UB-1.5 ... UB V DC |
| Discrepancy time | Acc. to EN IEC 60947-5-3 |
| Utilization category | |
| DC-13 | 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
| Electrical switching frequency | max. 0.25 Hz |
| Switching current | |
| per safety output FO1A / FO1B | 1 ... 150 mA |
| Operating voltage UB | |
| Operating voltage DC | |
| UUB | 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV |
| Current consumption | |
| IUB at operating voltage UB = 24 V | max. 500 mA |
Mechanical values and environment
| Anfahrgeschwindigkeit | max. 20 m/min |
| Connection type | Plug connector M12, 8-pin |
| Extraction force | 18 N |
| Ready delay | 5.5 s |
| Actuating force | 20 N |
| Installation orientation | any |
| Switching frequency | max. 0.25 Hz |
| Storage temperature | -25 ... 70 °C |
| Mechanical life | 1 x 10⁶ |
| Overtravel | 2 mm |
| Retention force | 5 N |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65/IP67 (In the inserted and screwed tight state) |
| Ambient temperature | |
| at UB = 24 V DC | -20 ... 60 °C |
| Material | |
| Seals | Fluorinated rubber (FKM) |
| Safety switch housing | Reinforced thermoplastic |
| Locking force Fmax | 1300 N |
| Locking force FZh | 1000 N |
| Guard locking principle | Open-circuit current principle |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Monitoring of the guard position | PL e | 3 | 4.11x10-9 | 4 | 20 y |
Miscellaneous
| Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Accessories

A-FLX-B-08-A1-A1-170487
- Use only in combination with CTM-CBI and CTM-C2 device variants
- Actuator for configuration of the switch with guard lock monitoring
- Ball actuator, rigid
- Door radii from 150 mm
- Two safety screws M4x14 are included.

A-FLX-B-09-A1-A1-170488
- Use only in combination with CTM-CBI and CTM-C2 device variants
- Actuator for configuration of the switch without guard lock monitoring
- Ball actuator, rigid
- Door radii from 150 mm
- Two safety screws M4x14 are included.
Downloads
Complete package
Download all important documents with a single click.
Content:
- The operating instructions and any additions to the operating instructions or brief instructions
- Any data sheets to supplement the operating instructions
- The declaration of conformity
Single Documents
Other Documents
Ordering data
| Ordernumber | 170491 |
| Item designation | CTM-C2-BP-HC-FLX-AZ-SA-170491 |
| Gross weight | 0,26kg |
| Customs tariff number | 85365019000 |
| ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |