EUCHNER – More than safety.
EUCHNER – More than safety.

CTP-I-AP-U-HA-ZZE-SBB-159614 (Order no. 159614)

Transponder-coded safety switch CTP-I-AP, 2 x M12, emergency stop (extended)

  • Safety switch without guard locking, with integrated evaluation electronics
  • Direct connection to decentralized peripheral systems (e.g. ET200pro)
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Up to category 4 / PL e according to EN ISO 13849-1
  • With 2 plug connectors M12
  • Unicode
  • Emergency stop
  • Approach directions A, B and C (delivery state)
CTP-I-AP-U-HA-ZZE-SBB-159614 (Order no. 159614)

Description

Approach direction

Horizontal

Can be adjusted in 90° steps

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in. Only the last actuator taught-in is detected.

Connector assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

X 1.1UBElectronics operating voltage 24 V DCBN
X 1.2FO1ASafety output, channel 1WH
X 1.30 V UBElectronics operating voltage 0 VBU
X 1.4FO1BSafety output, channel 2BK
X 1.5-n.c.GY
X 2.1S1.A1EMERGENCY STOP (channel A)BN
X 2.2S1.B1EMERGENCY STOP (channel B)WH
X 2.3-n.c.BU
X 2.4S1.A2EMERGENCY STOP (channel A)BK
X 2.5S1.B2EMERGENCY STOP (channel B)GY
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1LEDs: STATE green; LOCK yellow; DIA red
2EMERGENCY STOP
3Auxiliary release has no basic-position function *)
4Order actuator separately
5View Z
6Plug connector aligned X1 M12, 5-pin; plug connector aligned X2 M12, 5-pin
7Safety switch without auxiliary release *) Auxiliary release without function

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/11FCC_2AJ58-05_

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Operating and display elements

ItemExtrasColorDesignation1NumberLEDVersionNote slide-in labelSwitching elementSlide-in label
1Emergency stop2 PD

Electrical connection values

Fuse
external (operating voltage UB) 0.25 ... 8 A
Power consumption 1 W
Rated insulation voltage Ui 50 V
Rated impulse withstand voltage Uimp 0.5 kV
Operating voltage DC
UUB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24 V 150 mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads)
Switching load
according to UL 24V DC, Class 2 (alternatively, see operating instructions)
Safety class
EN IEC 61140 III
Current consumption
IUB 40 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30 nF and R<= 20 kohm)
Test pulse interval min. 100 ms
Degree of contamination (external, according to EN 60947-1) 3
Emergency stop
Operating voltage 5 ... 24 V
Operating current 1 ... 100 mA
Safety outputs FO1A / FO1B
Output type 2 semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1.5 ... UB V DC
Discrepancy time
both safety outputs max. 10 ms Acc. to EN IEC 60947-5-3
Turn-on time max. 400 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output FO1A / FO1B 1 ... 150 mA

Mechanical values and environment

Approach speed max. 20 m/min
Connection type 2 plug connector M12, 5-pin
Extraction force 20 N
Ready delay max. 1 s
Actuating force 10 N
Installation orientation any
Switching frequency max. 0.5 Hz
Mechanical life 1 x 10⁶
Overtravel 5 mm
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP65 (screwed tight plug connector/mating component)
Ambient temperature
at UB = 24 V DC -20 ... +55 °C
Material
Switch head cover Die-cast zinc
Safety switch housing Reinforced thermoplastic

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Category 4
Performance Level PL e
PFHD 4.1 x 10 -9
Emergency stop
B10D 0.065 x 10⁶

Miscellaneous

The following applies to the approval according to UL Operation only with UL Class 2 power supply or equivalent measures; see operating instructions
Detent mechanism Snap-in bolt

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 7,1 MB)

Single Documents

Other Documents

Ordering data

Ordernumber 159614
Item designation CTP-I-AP-U-HA-ZZE-SBB-159614
Gross weight 0,56kg
Customs tariff number 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com