EUCHNER – More than safety.
EUCHNER – More than safety.

CES-AP-C01-CH-SB-106798 (Order no. 106798)

Non-contact safety switch CES-AP-C01-...

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • M12 plug connector 5-pin
  • Multicode
CES-AP-C01-CH-SB-106798 (Order no. 106798)

Description

Approach direction

Can be adjusted in 90° steps

Short circuit monitoring

The switch generates its own clock signal on the output lines OA/OB.

Pay attention to this aspect when connecting to control systems and relays.

Multicode evaluation

Every suitable actuator is detected by the switch.

Category according to EN 13849-1

Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:

  • Category 4 / PL e according to EN 13849-1

Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated.

LED indicator

STATEStatus LED
DIADiagnostic LED

Additional connections

DIADiagnostics output (semiconductor)

Connector assignment

Plug connector (view of connection side)

Pin

Designation

Function

Conductor coloring of connecting cable

1

UB

Power supply, DC 24 V

BN

2

OA

Safety output, channel 1

GN

3

0V

Ground, DC 0 V

BU

4

OB

Safety output, channel 2

YE

5

DIA

Monitoring output

GY

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimension drawing

Dimension drawing
1LED status indication
2Active face

Wiring diagram

Wiring diagram

Technical data

Approvals

Zulassung EACRichtlinie CEZulassung c_UL_us LISTED Class 2

Mechanical values and environment

Shock and vibration resistance In acc. with EN 60947-5-3
Housing material
Housing Plastic, PBT
Weight
Net 0,12 kg
Ambient temperature -20 ... 55 °C
Degree of protection IP67
Mounting distance min.40 mm
Installation orientation Any
Tightening torque
Fixing screws max.1 Nm
Ready delay 0,5 s
Switching frequency max.1 Hz
Connection M12 plug connector, 5-pin

Electrical connection ratings

Operating voltage DC
UB 24 V DC 15% ... 15% Reverse polarity protected, regulated, residual ripple < 5 %, PELV
Current consumption
No load on outputs max.50 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 300 V (Tested by employers' liability insurance association up to 75V.)
Rated impulse withstand voltage Uimp 1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Turn-on time
Safety outputs max.400 ms
Safety class III
Risk time according to EN 60947-5-3 max.260 ms
Monitoring output DIA
Type of output p-switching, short circuit-proof
Switching current max.200 mA
Output voltage 0,8 x UB ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
Safety outputs OA/OB
Test pulses max.0,4 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 400 mA
Output voltage
LOW U(OA) / U(OB) 0 ... 1 V DC
HIGH U(OA) / U(OB) UB-1,5 ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
Utilization category acc. to EN 60947-5-2
DC-13 24V 400mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Rated conditional short-circuit current max.100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms

Work area

Repeat accuracy R
According to EN 60947-5-2 ≤10

Other

For the approval acc. to UL the following applies Operation only with UL class 2 power supply, or equivalent measures

Reliability values according to EN ISO 13849-1

Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 2.1 x 10-9 (Applying the limit value from EN ISO 13849-1:2008, section 4.5.2 (MTTFd = max. 100 years), BG certifies a PFHd of max. 2.47x10<sup>-8</sup>.)
Mission time 20

In combination with Actuator CES-A-BBA

Actuating range

Operating distance 18 mm
Assured release distance Sar max.45 mm (The values apply for surface installation)
Assured operating distance Sao min.15 mm (The values apply for surface installation)
Switching hysteresis min.1 mm (The values apply for surface installation)

In combination with Actuator CES-A-BRN-100251

Actuating range

Operating distance 27 mm
Assured release distance Sar max.75 mm
Assured operating distance Sao min.20 mm (The values apply for surface installation of the actuator on steel.)
Switching hysteresis 3 mm (The values apply for surface installation of the actuator on steel.)

In combination with Actuator CES-A-BPA

Actuating range

Operating distance 22 mm (For surface mounting on aluminum. In a non-metallic environment the typical operating distance increases to 30 mm)
Assured release distance Sar max.58 mm
Assured operating distance Sao min.18 mm
Switching hysteresis min.1 mm

In combination with Actuator CES-A-BDA-18-156935

Actuating range

Operating distance 19 mm (The values apply for surface installation)
Assured release distance Sar max.45 mm (The values apply for surface installation)
Assured operating distance Sao min.10 mm (The values apply for surface installation)
Switching hysteresis min.1 mm (The values apply for surface installation)

Accessories

Downloads

Doc. no.
Version
Language
Size
Doc. no. 2112663
Operating Instructions Non-Contact Safety Switch CES-AP-C01-... (Unicode/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,4 MB
Doc. no. 2112663
Mode d'emploi Interrupteur de sécurité sans contact CES-AP-C01-... (uni-/multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,4 MB
Doc. no. 2112663
Manual de instrucciones Interruptor de seguridad sin contacto CES-AP-C01-... (Unicode/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,4 MB
Doc. no. 2112663
Betriebsanleitung Berührungsloser Sicherheitsschalter CES-AP-C01-... (Uni-/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,4 MB
Doc. no. 2112663
Manual de instruções Chaves de segurança sem contato CES-AP-C01-... (Unicode/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,4 MB
Doc. no. 2112663
Istruzioni di impiego Finecorsa di sicurezza senza contatto CES-AP-C01-… (Unicode/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,4 MB
Doc. no. 2112663
使用说明书 非接触式安全开关 CES-AP-C01-⋯ (特殊/通用编码)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,6 MB
Doc. no. 2112663
Инструкция по эксплуатации Бесконтактный предохранительный выключатель CES-AP-C01-... (Uni-/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
1,6 MB
Doc. no. 2112663
Návod k použití Bezkontaktní bezpečnostní spínač CES-AP-C01-... (Unicode/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
2,5 MB
Doc. no. 2112663
Instrukcja obsługi Bezstykowy wyłącznik bezpieczeństwa CES-AP-C01-... (Uni-/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
2,5 MB
Doc. no. 2112663
Kezelési útmutató Érintkezésmentes biztonsági kapcsoló CES-AP-C01-... (uni-/multikód)
Doc. no.
2112663
Version
08-02/20
Language
Size
2,5 MB
Doc. no. 2112663
Návod na prevádzku Bezdotykový bezpečnostný spínač CES-AP-C01-... (Uni-/Multicode)
Doc. no.
2112663
Version
08-02/20
Language
Size
2,5 MB

Technical support

Technical support
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER (UK) Ltd.
+44 114 2560123
sales(at)euchner.co.uk

EUCHNER USA Inc.
+1 315 701-0315
info(at)euchner-usa.com