CES-AR-C01-CH-SA (Order no. 098942)

Safety switch CES-AR-C01-..., RFID, plug connector(s) M12

  • Multicode
  • Monitoring output door position OUT
  • Plug connector M12, 8-pin
CES-AR-C01-CH-SA (Order no. 098942)

Description

Approach direction and installation position

1 active face, adjustable in 5 directions

Multicode evaluation

The system checks whether the actuator type is one that can be recognized by the system (multicode evaluation). The system has a low coding level. Every suitable actuator is recognized by the switch.

Safety characteristics

Thanks to two redundant safety outputs (semiconductor outputs) with internal monitoring, the device is suitable for:

  • Category 4 /PL e according to EN 13849-1
  • SIL 3 according to EN IEC 62061 Table 4

The OSSD outputs used check their function for short circuits and short circuits with test pulses.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Typical actuating ranges

With actuators CES-A-BBA and CES-A-BCA

<p>With actuators CES-A-BBA and CES-A-BCA</p>

For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the actuating range of the side lobes is not entered.

With actuator CES-A-BPA

<p>With actuator CES-A-BPA</p>

For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Attention:

The actuating range may vary depending on the actuator, substrate material and installation situation. Further actuating ranges can be found in the operating instructions.

Plug connector(s) adjusted C01

Plug connector(s) adjustable in 6 orientations.

Terminal assignment

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1IBEnable input for channel 2WH
2UBPower supply, DC 24 VBN
3OASafety output, channel 1GN
4OBSafety output, channel 2YE
5OUTMonitoring outputGY
6IAEnable input for channel 1PK
70 VGround, DC 0 VBU
8RSTReset inputRD

Accessories required

Actuator is not included.

Wiring diagram
Wiring diagram

Connection examples

Connection examples

Technical data

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 75 V (Tested up to 75 V by employers' liability insurance association)
Rated impulse voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% reverse polarity protected, regulated, residual ripple<5%, PELV
Turn-on time
Safety outputs max. 400 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Risk time according to EN 60947-5-3 max. 260 ms
Risk time according to EN 60947-5-3, extension for each additional device max. 5 ms
Safety class III
Current consumption
no load on outputs max. 50 mA
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OUT
Output type p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
Switching current max. 200 mA
Safety outputs OA / OB
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
LOW U(OA,OB) 0 ... 1 V DC
HIGH U(OA,OB) UB-1.5 ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
rated conditional short-circuit current 100 A
Discrepancy time max. 10 ms
Utilization category
DC-13 24V 400mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Off-state current Ir max. 0.25 mA
Switching current
per safety output 1 ... 400 mA
Test pulse duration max. 1 ms

Mechanical values and environment

Connection type M12 plug connector, 8-pin
Tightening torque
Fixing screws max. 1 Nm
Ready delay 10 s
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance min. 40 mm
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67
Ambient temperature -20 ... 55 °C
Material
Housing Plastic, PBT

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e-2.1x10-9420 y


Miscellaneous

Notices for UL approval Operation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BDA-18-156935

Switch-on distance 19 mm (for surface mounting)
Secured switch-off distance sar max. 45 mm (for surface mounting)
Secured switching distance sao min. 10 mm (for surface mounting)
Switching hysteresis 1 ... 3 mm (for surface mounting)

In combination with actuator CES-A-BBA-071840

Switch-on distance 18 mm
Secured switch-off distance sar max. 45 mm (for surface mounting)
Secured switching distance sao min. 15 mm (for surface mounting)
Switching hysteresis 1 ... 3 mm (for surface mounting)

In combination with actuator CES-A-BRN-100251

Switch-on distance 27 mm
Secured switch-off distance sar max. 75 mm
Secured switching distance sao min. 20 mm (The values apply to surface mounting of the actuator on steel.)
Switching hysteresis 3 mm (The values apply to surface mounting of the actuator on steel.)

In combination with actuator CES-A-BPA-098775

Switch-on distance 22 mm (on surface mounting on aluminum. In a non-metallic environment, the typical operating distances increase to 30 mm)
Secured switch-off distance sar max. 58 mm
Secured switching distance sao min. 18 mm
Switching hysteresis 1 ... 2 mm

Accessories

Downloads

Complete package

Download all important documents with a single click.

Content:

  • The operating instructions and any additions to the operating instructions or brief instructions
  • Any data sheets to supplement the operating instructions
  • The declaration of conformity
Download Complete Package (ZIP, 14,8 MB)

Single Documents

Doc. no.
Version
Language
Size
Doc. no. 2098039
Operating Instructions Non-Contact Safety Switch CES-AR-C01-... (Unicode/Multicode/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
1,6 MB
Doc. no. 2098039
Mode d'emploi Interrupteur de sécurité sans contact CES-AR-C01-... (unicode / multicode/ code fixe)
Doc. no.
2098039
Version
20-02/20
Language
Size
1,6 MB
Doc. no. 2098039
Manual de instrucciones Interruptor de seguridad sin contacto CES-AR-C01-... (Unicode/Multicode/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
1,6 MB
Doc. no. 2098039
Betriebsanleitung Berührungsloser Sicherheitsschalter CES-AR-C01-... (Uni-/Multi-/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
1,6 MB
Doc. no. 2098039
Istruzioni di impiego Finecorsa di sicurezza senza contatto CES-AR-C01-... (Uni-/Multi-/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
1,6 MB
Doc. no. 2098039
使用说明书 非接触式安全开关 CES-AR-C01-⋯ (特殊/通用/固定编码)
Doc. no.
2098039
Version
20-02/20
Language
Size
2,1 MB
Doc. no. 2098039
Инструкция по эксплуатации Бесконтактный предохранительный выключатель CES-AR-C01-... (Uni-/Multi-/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
2,1 MB
Doc. no. 2098039
Návod k použití Bezkontaktní bezpečnostní spínač CES-AR-C01-... (Unicode/Multicode/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
2,8 MB
Doc. no. 2098039
Érintkezésmentes biztonsági kapcsoló CES-AR-C01-… (Uni-/multi-/állandó kód)
Doc. no.
2098039
Version
20-02/20
Language
Size
1,6 MB
Doc. no. 2098039
İşletim kılavuzu Temassız emniyet şalteri CES-AR-C01-... (Uni-/Multi-/Fixcode)
Doc. no.
2098039
Version
20-02/20
Language
Size
2,0 MB
Doc. no. 2098039
Instrucţiuni de utilizare Întrerupător de siguranţă fără contact CES-AR-C01-... (cod unic/mai multe coduri/cod fi x)
Doc. no.
2098039
Version
20-02/20
Language
Size
2,8 MB

Other Documents

Ordering data

Ordernumber 098942
Item designation CES-AR-C01-CH-SA
Gross weight 0,191kg
Customs tariff number 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch