EUCHNER – More than safety.
EUCHNER – More than safety.
KezdőlapProductsRGBF02R16-502-M

RGBF02R16-502-M (Rend. sz. 082343)

Series RGBF... 16 mm mechanical

  • Plunger spacing 16 mm
  • Upright housing according to DIN 43697
  • Degree of protection IP67 according to IEC 60529
RGBF02R16-502-M (Rend. sz. 082343)

Ismertetés

Switching element

ES 502 ESnap-action switching contact 1 NC + 1 NO

On the usage of safety switching elements, the dog distance must be maintained to achieve the positively driven travel. The dogs must be positively mounted according to EN 1088, i.e. riveted, welded or secured in some other way against becoming loose.

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimension drawing

Dimension drawing
1Operating point
2Free position
3Safety switching element ES 502 E positive opening. Positive opening function is dependent on maintaining this distance. Actuators (dogs) must be connected to the machine in a flush position. Switch can be replaced only with the same type.
4Groove with sealing ring
5Number of plungers

Wiring diagram

Wiring diagram

Műszaki adatok

Engedélyezések

Zulassung EAC

Mechanikai értékek és környezet

Design Upright, according to DIN 43697
Housing material
Housing Die-cast aluminum, anodized
Weight
Net 0,85 kg
Ambient temperature -5 ... 80 °C
Degree of protection IP67
Mechanical life 30 x 106
Contact material Silver alloy, gold flashed
Switching principle Snap-action switching contact (Contact closing time < 4 contact bounce time < 3)
Plunger spacing 16 mm
Installation orientation Any
Number of switching elements 2
Number of NC contacts 2
Number of NO contacts 2
Connection
4 x M25 x 1.5
Approach speed 0,01 ... 80 m/min
Actuating element
Plain bearing Roller plunger (Operating point accuracy ± 0.01. The reproducible switching point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has been run-in with approx. 2000 operating cycles.)
Actuating force min.20 N

Elektromos csatlakoztatási értékek

Thermal rated current Ith 8 A
Utilization category acc. to EN 60947-5-1
AC-15 6A 230V
DC-13 6A 24V
AC-12 8 A, 250 V
Short circuit protection according to IEC 60269-1 8A gG
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching current
Min. at DC 12V min.10 mA
Connection cross-section 0,34 ... 1,5 mm²

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu