EUCHNER – More than safety.
EUCHNER – More than safety.

LCA-2TR-40-310-AP-156648 (Rend. sz. 156648)

Light curtain LCA-2TR-40-310

  • Resolution 40 mm
  • Protective field height 310 mm
  • Range 12 m
  • With plug connector M12
  • 2 safety outputs (OSSD)
  • Installation material is included with the product
LCA-2TR-40-310-AP-156648 (Rend. sz. 156648)

Ismertetés

Protective function

Hand protection

LED function display

Transmitter

Receiver

LED OK

Normal operation

LED ERROR

Fault state

LED STOP

Stop state

LED TEST

Test function

LED START

Start/restart

Connector assignment, transmitter

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

124 V DCOperating voltage, 24 V DCBN
2RANGE 0Device configuration, corresponds to the standard EN 61131-2WH
30 V DCOperating voltage, 0 V DCBU
4RANGE 1Device configuration, corresponds to the standard EN 61131-2BK
5FEFunctional earth (must be connected to meet the EMC requirements)GY

Connector assignment, receiver

Plug connector (view of connection side)PinDesignationFunctionConnecting cable conductor coloring

1FO1ASafety output, channel 1WH
224 V DCOperating voltage, 24 V DCBN
3FO1BSafety output, channel 2GN
4K1_K2/RESTARTFeedback external contactorsYE
5SEL_ADevice configurationGY
6SEL_BDevice configurationPK
70 V DCOperating voltage, 0 V DCBU
8FEFunctional earth (must be connected to meet the EMC requirements)RD
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram
Wiring diagram receiver
Wiring diagram receiver
Wiring diagram transmitter
Wiring diagram transmitter
Light grids and light curtains

Dimensional drawings

Dimensional drawings
A = Height of the sensor (see technical data)

Dimensional drawings

Dimensional drawings
AFastening bracket
BMounting plate

Connection examples

Connection examples

Connection examples

Connection examples

Műszaki adatok

Approvals

TÜV SÜD München_LCA2_Z10 040393 0044 Rev.00c_UL_us_E492607

Operating and display elements

LED display yes (Self-diagnostics and status)

Electrical connection values

Receiver power consumption 2 W
Transmitter power consumption 1 W
Operating voltage DC 24 V DC -20% ... +20%
Cascadable no
Muting possible in combination with external sensors and an evaluation unit
Current consumption 400 mA

Mechanical values and environment

Dimensions 28x30 mm (in cross-section)
Connection type Plug connector M12 (5-pin transmitter/8-pin receiver)
Number of safety outputs 2 static, self-monitoring PNP safety outputs (with short-circuit and overload protection)
Resolution 40 mm
Installation orientation any (Optional: adjustable holders)
Height of the protective field 310 mm
Height of the sensor 363 mm
maximum length of connecting cables 100 m
Response time 5 ms
Range of the protective field 12000 mm
Degree of protection IP65/IP67
Ambient temperature -30 ... +55 °C

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Safety Integrity Level SIL 1 / SILCL 1

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the protective fieldPL c12.3x10-8220 y


Miscellaneous

ESPE type 2 (according to EN 61496-1)

Tartozékok

Letöltések

Teljes csomag

Minden fontos dokumentum letöltése egyetlen kattintással.

Tartalom:

  • A használati utasítás és a használati utasítás vagy a rövid utasítás kiegészítései
  • A használati utasítást kiegészítő adatlapok
  • A megfelelőségi nyilatkozat
Teljes csomag letöltése (ZIP, 8,1 MB)

Egyedi dokumentumok

Egyéb dokumentumok

Rendelési adatok

Rend. sz. 156648
Cikk neve LCA-2TR-40-310-AP-156648
Súly 1,541kg
Vámtarifaszám 85365019000
ECLASS 27-27-09-10 Light curtain

Műszaki támogatás

Műszaki támogatás
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER Magyarország Kft.
+36 1919 0855
info(at)euchner.hu