AnasayfaProductsRGBF06D12-502LE060-M

RGBF06D12-502LE060-M (Sip. No. 087109)

Series RGBF... 12 mm mechanical

  • Plunger spacing 12 mm
  • Upright housing according to DIN 43697
  • Degree of protection IP67 according to IEC 60529
  • LED function display optional
RGBF06D12-502LE060-M (Sip. No. 087109)

Açıklama

Switching element

ES 502 ESnap-action switching contact 1 NC + 1 NO

On the usage of safety switching elements, the dog distance must be maintained to achieve the positively driven travel. The dogs must be positively mounted according to EN 1088, i.e. riveted, welded or secured in some other way against becoming loose.

LED function display

Function display is available for the following voltage range (see accessories)

LE06012 ... 60 V AC/DC
Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimension drawing

1Operating point
2Free position
3Groove for sealing ring
4LED indicator
5Number of plungers

Wiring diagram

Teknik Veriler

Onaylar

Zulassung EAC

Mekanik Değerler ve Çevre

Design Upright, according to DIN 43697
Housing material
Housing Die-cast aluminum, anodized
Weight
Net 1,3 kg
Ambient temperature -5 ... 80 °C
Degree of protection IP67
Mechanical life 30 x 106
Contact material Silver alloy, gold flashed
Switching principle Snap-action switching contact (Contact closing time < 4 ms contact bounce time < 3 ms)
Plunger spacing 12 mm
Installation orientation Any
Number of switching elements 6
Number of NC contacts 6
Number of NO contacts 6
Connection
4 x M25 x 1.5
Approach speed 0,01 ... 40 m/min
Actuating element Chisel plunger (Operating point accuracy ± 0.002. The reproducible switching point accuracy refers to the axial travel of the plunger after the switching element ES 502 E has been run-in with approx. 2000 operating cycles.)
Actuating force min.20 N

Elektriksel Bağlantı Değerleri

Thermal rated current Ith 8 A
Utilization category according to EN 60947-5-1
AC-15 6A 230V
DC-13 6A 24V
AC-12 8 A, 250 V
Short circuit protection according to IEC 60269-1 8A gG
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching current
Min. at DC 12V min.10 mA
Connection cross-section 0,34 ... 1,5 mm²
Display module
AC/DC 60 V 12 ... 60 V LED