EUCHNER – More than safety.
EUCHNER – More than safety.

STP4A-4131A024M (Sip. No. 093158)

Safety switch STP with door monitoring contact

  • Actuating head made of metal
  • Auxiliary release on the front
  • With door monitoring contact
STP4A-4131A024M (Sip. No. 093158)

Açıklama

Approach direction

Horizontal and vertical

Can be adjusted in 90° steps

Solenoid operating voltage

  • AC/DC 24 V +10%, -15%

Guard locking type

STP4

Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force.

Switching element

4131

Slow-action switching contact 2 NC + 1 NO + 1 NO (door monitoring contact)

Auxiliary release

This is used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.

Switching function
Switching function
Dimension drawing
Dimension drawing
Wiring diagram 4131
Wiring diagram 4131
Electromechanical safety switches in use

Functional drawings

Functional drawings

Dimensional drawings

Dimensional drawings
1Auxiliary release
2Locking screw

Connection examples

Connection examples
Door monitoring
Solenoid monitoring

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20DGUV_STP_ET20006_ET20007c_UL_us_E155795_2/1CCC_2020980305000541_CQC2008010305306207

Electrical connection values

Power consumption 8 W
Connection cross section 0.34 ... 1.5 mm²
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2.5 kV
Utilization category
AC-15 4 A 230 V
DC-13 4 A 24 V
Short circuit protection according to IEC 60269-1 4A gG
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Solenoid duty cycle 100 %
Switching voltage
min. at 10 mA 12 V
Switching current
min. at 24 V 1 mA
thermal rated current Ith 4 A

Mechanical values and environment

Approach speed max. 20 m/min
Approach direction A
Connection type
3 x M20 x 1.5
Number of door position NO contacts 1
Number of guard lock monitoring NO contacts 1
Number of guard lock monitoring positively driven contacts 2
Extraction force 30 N
Actuation frequency max. 1200 1/h
Actuating force 35 N
Installation orientation any
Insertion depth 24.5 mm
Mechanical life 1 x 10⁶
Retention force 20 N
Switching principle Slow-action switching contact
Degree of protection IP67
Ambient temperature -20 ... +55 °C
Material
Housing Reinforced thermoplastic
Contact Silver alloy, gold flashed
Locking force Fmax 2500 N
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

B10DMission time
Monitoring of the guard position5x10620 y
Important! Values valid at DC-13 100 mA/24V
Monitoring of guard locking5x10620 y
Important! Values valid at DC-13 100 mA/24V


In combination with actuator ACTUATOR-S-GT-SN

Overtravel 5 mm

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 7,7 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 093158
Makale adı STP4A-4131A024M
Ağırlık 0,52kg
Gümrük sınıfı 85365019000
ECLASS 27-27-26-03 Safety switch with guard control

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr