EUCHNER – More than safety.
EUCHNER – More than safety.

CEM-A-LH10R-S3 (Sip. No. 095793)

Read head CEM-A-LH10R-S3 with guard locking without guard lock monitoring without remanence

  • Read head with guard locking without guard lock monitoring
  • Locking force 1000 N
  • Without remanence
  • Up to category 4 according to EN ISO 13849-1
CEM-A-LH10R-S3 (Sip. No. 095793)

Açıklama

Combination options

Suitable for connection to a CES-AZ evaluation unit

Without remanence

Read heads without remanence are demagnetized when the solenoid is switched off. For this purpose the operating voltage UB must always be applied.

Approach direction

<p>Approach direction</p>

Typical actuating range

<p>Typical actuating range</p>

Note assured release distance sar = 20 mm for internal component failure. Safety outputs are safely switched off.

Dimension drawing
Dimension drawing
Connection solenoid operating voltage plug S1. A free-wheeling diode is already integrated into each CEM.
Connection solenoid operating voltage plug S1. A free-wheeling diode is already integrated into each CEM.
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings

Connection examples

Connection examples
Evaluation unit CES
X1.1U
X1.2+U
X1.30 V/GND
X1.4Functional earth
X2.1LED +
X2.2-
X2.3LED 0 V
X2.4-
X3.1Data line
X3.3Data line
X3.4SH (screen)

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E155795_3/5

Workspace

Secured switch-off distance sar max. 20 mm (in combination with evaluation unit CES-A-...B or CES-AZ-...B)
Secured switching distance sao
with center offset m=0 min. 2 mm (in combination with evaluation unit CES-A-...B or CES-AZ-...B)
Center offset -2.5 ... +2.5 mm
Switching hysteresis
with center offset m=0 0.7 mm (in combination with evaluation unit CES-A-...B or CES-AZ-...B)

Electrical connection values

Power consumption 5.8 W
Operating voltage DC
UB 24 V DC -15% ... +10%
UCM 24 V DC -15% V DC ... +10% V DC
Solenoid duty cycle 100 %
Current consumption
at UCM at 24 V 15 mA
at UB at UCM=24 V 225 mA
at UB at UCM=0 V 12 mA

Mechanical values and environment

Connection type
X2, external LED Plug connector M8x1, 4-pin socket (with screw terminal)
X3, read head Plug connector M8x1, 3-pin, plug (with snap-action/screw terminal)
X1, solenoid (yellow LED integrated in the plug) Plug connector M8x1, 4-pin, plug (with snap-action/screw terminal)
Installation orientation any
Switching frequency
Solenoid max. 2 Hz
Adhesive force
due to remanence 0.7 N
Cable length max. 25 m
Read head material Plastic (PPS)
Mechanical life
in case of use as door stop, and 1 Joule impact energy 1 x 10⁶
Degree of protection IP67
Ambient temperature -25 ... +50 °C
Material
Solenoid Steel, nickel plated
Read head Plastic (PPS)
Housing Die-cast aluminum
Locking force F
(not monitored, in axial direction) at UCM=24 V 1000 N
Guard locking principle Open-circuit current principle

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 1,5 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 095793
Makale adı CEM-A-LH10R-S3
Ağırlık 0,859kg
Gümrük sınıfı 85365019000
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking

Teknik Destek

Teknik Destek
Do you have technical questions about our products, their possible use or applications? Our experts will be happy to help.

EUCHNER End. Emn. Tek. Ltd. Sti.
+90 216 521-1000
info(at)euchner.com.tr