Basic device ESM-BA2.., 2 safety contacts, cat. 4
- ESM-BA.. Use up to category 4 according to EN ISO 13849-1
- LED status indicators
- 1-channel or 2-channel control
- 2 redundant safety contacts
- Short circuit and earth fault/ground fault monitoring
- plug-in connection terminals
Açıklama
Relay outputs
The outputs are electrically decoupled and of redundant design.
Connection options
By using suitable wiring, the following functions can be selected:
- Relay start with automatic start or a start button
- Monitoring of downstream relays or contactors.
- Simultaneity monitoring to monitor safety components over time
- Relay start using a monitored start button
- Short circuit monitoring to detect short circuits between the connecting cables and to shut down the outputs or prevent relay starting if necessary
- Earth fault/ground fault monitoring to detect short circuits between the connecting cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.
Important:
Depending on the device in question, a connection kit will be required.
Dimensional drawings
ESM-BA2... |
Connection examples
Teknik Veriler
Onaylar
Mekanik Değerler ve Çevre
Housing material | |
Housing | Polyamide PA6.6 |
Weight | |
Net | 0,23 kg |
Ambient temperature | |
At UB = 24V DC | -15 ... 60 °C (at 20% undervoltage T<sub>max</sub>: 50°C) |
At UB = 24V AC | -15 ... 40 °C |
Degree of protection | IP20 |
Mechanical life | |
operating cycles | 10 x 106 |
Contact material | AgSnO2 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Connection | Plug-in connection terminals |
Length of control cable | |
With conductor cross-section 0.75mm2 | 1000 m |
Safety contacts 13/14, 23/24 | |
Number of safety contacts | 2 |
Elektriksel Bağlantı Değerleri
Operating voltage | |
AC/DC | 24 V -10% ... +10% (All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN 61558-2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.) |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | |
Leakage path/air gaps | 4 kV |
Overvoltage category according to IEC EN 60664-1 | 3 |
Reverse polarity protection | |
On version UB =24V DC | |
Connection rating | |
at 24V DC | 1,5 W |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 ... 2,5 mm² (Connection terminal (size)) |
Test voltage | |
Control system/contacts | 2,5 kV |
Control voltage | |
On S11 | 24 V 18,6 ... 26 V Start button |
Control current | |
S11...S14 | 40 mA |
LED indicator | 2 status displays (green) for relays K1 and K2 |
Safety contacts 13/14, 23/24 | |
Type of output | |
NO | Relay contacts, floating, positively driven (redundant) (Positively driven relay according to EN 50205) |
Switching voltage | |
AC | max.250 V |
DC | max.24 V |
Switching current | min.20 mA at 24V |
Fusing | |
External contact fuses (safety circuit) according to IEC 60269-1 | 10A gG |
Utilization category acc. to EN 60947-5-1 | |
AC-15 | 3A, 250V |
DC-13 | 3A, 24V |
AC-12 | 6A ohmic load, 250V (6 operating cycles/min.) |
DC-12 | 6A ohmic load, 24V (6 operating cycles/min.) |
Çeşitli
In compliance with | EN ISO 13849-1: 2015; EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015; EN 50581: 2012 (RoHS) |
EN ISO 13849-1 uyarınca güvenilirlik değerleri
Performance Level | PL e (This value is dependent on the number of switching cycles and the switching current.) |
Category | 4 (This value is dependent on the number of switching cycles and the switching current.) |
PFHD | 1.2 x 10-8 (This value is dependent on the number of switching cycles and the switching current.) |
Number of switching cycles | |
≤ 0.1 A at 24 V DC | max.400000 1/Jahr |
≤ 1 A at 24 V DC | max.100000 1/Jahr |
≤ 3 A at 24 V DC | max.22500 1/Jahr |
Mission time | 20 y (This value is dependent on the number of switching cycles and the switching current.) |
Aksesuar
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Declarations of conformity
EU-Konformitätserklärung
Dok. No.
Versiyon
Dil
Boyut
EU-Konformitätserklärung
Dok. No.
EDC2090791
Versiyon
Dil
Boyut
0,2 MB
Instructions
Operating Instructions Safety Relay ESM-BA2..
Dok. No.
Versiyon
Dil
Boyut
Operating Instructions Safety Relay ESM-BA2..
Mode d’emploi Unité de base ESM-BA2..
Manual de instrucciones Módulo básico ESM-BA2..
Betriebsanleitung Basisgerät ESM-BA2..
Mode d’emploi Unité de base ESM-BA2..
Manual de instrucciones Módulo básico ESM-BA2..
Betriebsanleitung Basisgerät ESM-BA2..
Dok. No.
2090071
Versiyon
01/24
Dil
Boyut
1,6 MB
Betriebsanleitung Basisgerät ESM-BA2..
Dok. No.
2090071
Versiyon
01/24
Dil
Boyut
0,6 MB
사용 설명서 안전 릴레이 ESM-BA2..
Dok. No.
2090071
Versiyon
01/24
Dil
Boyut
0,8 MB
Diğer Belgeler
Application examples
Approvals and certificates
TÜV Rheinland
Dok. No.
Versiyon
Dil
Boyut
TÜV Rheinland
Dok. No.
20001714
Versiyon
Dil
Boyut
0,6 MB
c UL us
Dok. No.
Versiyon
Dil
Boyut
c UL us
Dok. No.
Versiyon
Dil
Boyut
1,0 MB
c UL us
Dok. No.
Versiyon
Dil
Boyut
0,2 MB
Sales documents
Interrupteurs de sécurité à codage magnétique CMS
Dok. No.
Versiyon
Dil
Boyut
Interrupteurs de sécurité à codage magnétique CMS
Dok. No.
090606
Versiyon
10-11/20
Dil
Boyut
5,8 MB
Magnetically Coded Safety Switches CMS
Dok. No.
Versiyon
Dil
Boyut
Magnetically Coded Safety Switches CMS
Dok. No.
086824
Versiyon
10-11/20
Dil
Boyut
5,7 MB
Sipariş verileri
Sip. No. | 097226 |
Makale adı | ESM-BA201P |
Ağırlık | 0,181kg |
Gümrük sınıfı | 85364110 |
ECLASS | 27-37-18-19 Device for monitoring of safety-related circuits |