CES-AP-CR2-AH-L20-106195 (Sip. No. 106195)

Safety switch CES-AP-CR2-..., RFID, connection cable, connecting cable PVC

  • Unicode
  • Monitoring output door position OUT
  • Connection cable, connecting cable PVC, 20 m, flying lead, 6-core
  • Door hinge right
  • Suitable for low ambient temperatures
CES-AP-CR2-AH-L20-106195 (Sip. No. 106195)

Açıklama

Approach direction and installation position

Permissible installation position

Typical operating distance

(Actuator CES-A-BLN... in conjunction with safety switch CES-AP-C.2-... in case of mounting on plastic)

For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the actuating range of the side lobes is not entered.

Attention:

The actuating range may vary depending on the actuator, substrate material and installation situation. Further actuating ranges can be found in the operating instructions.

Unicode evaluation

Each actuator is highly coded (unicode). The switch detects only taught-in actuators. Additional actuators can be taught-in.

Only the last actuator taught-in is detected.

Safety characteristics

Thanks to two redundant safety outputs (semiconductor outputs) with internal monitoring, the device is suitable for:

  • Category 4 /PL e according to EN 13849-1
  • SIL 3 according to EN IEC 62061 Table 4

The OSSD outputs used check their function for short circuits and short circuits with test pulses.

LED indicator

STATE

Status LED

DIA

Diagnostics LED

Terminal assignment

DesignationFunctionConnecting cable conductor coloring
UBPower supply, DC 24 VBN
OASafety output, channel 1WH
0 VGround, DC 0 VBU
OBSafety output, channel 2BK
OUTMonitoring outputGY
-n.c.PK

Scope of delivery

  • 2 x safety screws M4x14

Accessories required

Dimension drawing
Dimension drawing
Wiring diagram
Wiring diagram

Dimensional drawings

Dimensional drawings
1Active face
2Fastening lug with reinforcement plate
3LED status indication
4Active face

Connection examples

Connection examples

Teknik Veriler

Approvals

EAC_RU C-DE.MO05.B.00971/20c_UL_us_E346349_1/1

Workspace

Repeat accuracy R
according to EN 60947-5-2 10 %

Electrical connection values

Fuse
external (operating voltage) 0.25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse voltage Uimp 1.5 kV
Operating voltage DC
UB 24 V DC -15% ... +15% regulated, residual ripple<5%
Turn-on time
Safety outputs max. 300 ms
EMC protection requirements Acc. to EN IEC 60947-5-3
Utilization category
DC-13 24V 150mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads.)
Risk time according to EN 60947-5-3 max. 260 ms
Safety class III
Current consumption max. 30 mA (without taking into account the load currents on the monitoring output and the safety outputs)
Degree of contamination (external, according to EN 60947-1) 3
Monitoring output OUT
Output type p-switching, short circuit-proof
Output voltage 0.8 x UB ... UB V DC
Switching current max. 50 mA
Safety outputs OA / OB
Output type Semiconductor outputs, p-switching, short circuit-proof
Output voltage
HIGH U(OA,OB) UB-1.5V ... UB V DC (Values at a switching current of 50 mA without taking into account the cable lengths.)
LOW U(OA,OB) 0 ... 1 V DC
rated conditional short-circuit current 100 A
Discrepancy time max. 10 ms
Off-state current Ir max. 0.25 mA
Switching current
per safety output 1 ... 150 mA
Test pulse duration max. 0.3 ms (Applies to a load with C<= 30nF and R<= 20kOhm)
Test pulse interval min. 100 ms

Mechanical values and environment

Connection type Connecting cable PVC, length 20 m
Tightening torque
Fixing screws max. 1 Nm
Ready delay 0.5 s
Dynamic bending radius 10 x cable diameter
Static bending radius 5 x cable diameter
Installation orientation any
Switching frequency max. 1 Hz
Mounting distance
between switches min. 400 mm
Mounting type Surface mounting on metal
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP67/IP69K
Cable ambient temperature (dynamic) 0 ... 65 °C
Cable ambient temperature (static) -40 ... 65 °C
Material
Housing Plastic, PBT

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

PLMaximum SILPFHDCategoryMission time
Monitoring of the guard positionPL e-1.8x10-9420 y


Miscellaneous

Notices for UL approval Operation only with UL Class 2 power supply or equivalent measures

In combination with actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710

Switch-on distance 15 mm
Secured switch-off distance sar
in x/z direction max. 40 mm
in y direction max. 60 mm
Secured switching distance sao min. 10 mm
Switching hysteresis 1 ... 2 mm

In combination with actuator CES-A-BDN-06-104730

Switch-on distance 19 mm
Secured switch-off distance sar
in y direction max. 60 mm
in x/z direction max. 40 mm
Secured switching distance sao min. 14 mm
Switching hysteresis 1 ... 2 mm

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 5,2 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 106195
Makale adı CES-AP-CR2-AH-L20-106195
Ağırlık 0,829kg
Gümrük sınıfı 85365019000
ECLASS 27-27-24-03 Safety-related transponder switch