Evaluation module with control and bus module MGB-...-PN with 11 controls and indicators, push-pull plug, RC12

  • Control panel
  • Emergency stop according to ISO 13850
  • 8 illuminated pushbuttons
  • Operating mode selector
  • 1 indicator
  • including adhesive labels
  • Push-pull plug
  • including terminal plug for enabling switch (RC12, 12-pin)
  • Pre-assembled on mounting plates
  • Integrated Profinet RT switch
MGB-L2CB-PNC-R-114778 (Sip. No. 114778)

Açıklama

Profinet connection

Connection via push-pull plugs according to IEC 61076-3-117

Profinet RT switch

Point-to-point topology network structure due to integrated RT switch.

Dimension drawing
Dimension drawing

Dimensional drawings

Dimensional drawings

Teknik Veriler

Approvals

TUEV Süd München_M6A 040393 0042 Rev. 00c_UL_us_E155795_3/9EAC_RU C-DE.HX37.B.14157/20

Workspace

Secured switch-off distance sar
Door position max. 65 mm

Operating and display elements

Occupancy diagram
C3
B2
L2
ItemColorExtrasSwitching elementNote slide-in labelVersionSlide-in labelNumberDesignation1LED
1Green1NOIlluminated pushbuttonInicia estação
11GreenCover for indicatorsÁrea segura
12Yellow1NOIlluminated pushbuttonRearma área segura
13Code 2 of 3Operating mode selectorDestravada ; Travada ; Travada central
2Red1NOIlluminated pushbuttonPara estação
3Green1NOIlluminated pushbuttonLiga água de refrigeração
4white1NOIlluminated pushbuttonFim de ciclo
5white1NOIlluminated pushbuttonohne Aufschrift
6Red1NOIlluminated pushbuttonDesliga água de refrigeração
72 PDEmergency stop
8white1NOIlluminated pushbuttonLibera porta de segurança

Electrical connection values

Connecting cable
Ethernet Profinet I/O cable, at least cat. 5e
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp 0.5 kV
EMC protection requirements In accordance with EN 61000-4 and EN 61326-3-1
maximum feed-in current in the connection block
X1, X2 max. 4000 mA
Safety class III
Current consumption max. 500 mA
Transponder coding Multicode
Degree of contamination (external, according to EN 60947-1) 3
Power supply X1
Fuse
external min. 1 A slow blow
Operating voltage DC
L1 24 V DC -15% ... +10% ((reverse polarity protected, regulated, residual ripple<5%, PELV))
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (The auxiliary voltage is not required for the MGB system)
Power supply X2
Operating voltage DC
L1 24 V DC -15% ... +10% (For looping through for connected devices)
Auxiliary voltage DC
L2 24 V DC -15% ... +10% (For looping through for connected devices)

Mechanical values and environment

Connection type
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X4 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Push-pull power (X1 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
according to IEC 61076-3-117, variant 14, screened, Profinet I/O cable, at least cat. 5e Push-pull RJ45 (X3 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Plug connector RC12 (X14)
Push-pull power (X2 (The document PROFINET “Cabling and Interconnection Technology” from the PNO aids in the correct selection of cables.))
Installation orientation Door hinge DIN right
Switching frequency 0.25 Hz
Mechanical life
in case of use as door stop, and 1 Joule impact energy 0.1 x 10⁶
1 x 10⁶
Response time
Enabling switch max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Bolt position max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Emergency stop / machine stop max. 250 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Door position max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Guard locking max. 550 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Operating mode selector max. 220 ms Turn-off time (The reaction time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.)
Shock and vibration resistance Acc. to EN IEC 60947-5-3
Degree of protection IP54
Ambient temperature
at UB = 24 V DC -20 ... +55 °C
Material
Housing Fiber glass reinforced plastic, nickel-plated die-cast zinc, stainless steel
Locking force FZh 2000 N
Guard locking principle Open-circuit current principle

Characteristic values according to EN ISO 13849-1 and EN IEC 62061

Mission time 20 y
Safety Integrity Level SIL 3 (EN 62061:2005)
Emergency stop
B10D
Emergency stop 0.13 x 10⁶
Enabling switch
B10D
Enabling switch (Acc. to manufacturer’s specifications)
Emergency-stop evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Enabling switch evaluation
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Evaluation of multi-position switch
Category 4
Performance Level PL e
PFHD 4.1 x 10-8
Monitoring of guard locking and the guard position
Diagnostic Coverage (DC) 99 %
Category 4
Performance Level PL e
PFHD 4.07 x 10-8 (Fixed failure rate without consideration of faults in wearing parts.)

Miscellaneous

Product version number V3.30.10

Interface

Bus data protocol Profinet (IEC 61158 type 10)
Safety data protocol Profisafe (IEC 61784-3-3)
Date interface
Ethernet

Aksesuar

İndirme

Komple paket

Tüm önemli belgeleri tek bir tıklama ile indirin.

İçerik:

  • Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
  • Kullanım talimatlarını tamamlayan tüm veri sayfaları
  • Uygunluk beyanı
Paketin tamamını indirin (ZIP, 6,1 MB)

Tek Belgeler

Diğer Belgeler

Sipariş verileri

Sip. No. 114778
Makale adı MGB-L2CB-PNC-R-114778
Ağırlık 4,54kg
Gümrük sınıfı 85371098
ECLASS 27-27-24-05 Safety-related transponder switch with guardlocking