CTS-C2-BP-CC-FLX-AP-VSA-169051 (Sip. No. 169051)
Safety switch with guard locking CTS-C2-BP FlexFunction, RFID, connection cable, connecting cable PVC with plug connector(s) M12
- Open-circuit current principle
- Guard locking suitable for process protection only
- Monitoring outputs guard locking (OL) and door position 1 (OD)
- Connection cable, connecting cable PVC, 25 cm, plug connector(s) M12, 8-pin

Açıklama
FlexFunction
The switch is configured by the function actuator during setup. Depending on the selection of the function actuator, the guard lock monitoring of the safety switch is active or inactive and the evaluation of the actuator code is high-coded or low-coded.
Guard locking principle
Open-circuit current (power on to lock): On a guard with guard locking based on the open-circuit current principle, the guard is locked until the power supply to the guard locking solenoid is interrupted. Unlocking is by spring force. The term electrical guard locking is also used.
Guard locking for process protection
The safety switch meets the requirements for interlocking devices with guard locking for process protection. It does not possess safe guard lock monitoring.
Auxiliary release
The auxiliary release on the front and rear sides allows access to the machine in the event of a malfunction, e.g. a power failure.
Terminal assignment
The function of the monitoring output OX is determined by the actuator that has been actuated.
Assignment of pins 5 and 6 depends on the function actuator
| Pin | A-FLX-D-0C-167919 | A-FLX-D-0D-169044 | A-FLX-D-0E-169045 | A-FLX-D-0F-169046 |
|---|---|---|---|---|
| L + HC | I + HC | L + LC | I + LC | |
| 5 | OL/C guard locking / communication | OL/C guard locking / communication | OL/C guard locking / communication | OL/C guard locking / communication |
| 6 | OD door position 1 | OD door position 1 | OD door position 1 | OD door position 1 |
Accessories required
Actuator is not included.


Dimensional drawings

| 1 | Auxiliary release |
| 2 | LEDs |
Connection examples

Teknik Veriler
Approvals


Electrical connection values
| Fuse | |
| UB | 1 ... 8 A external |
| IMP | 1 ... 8 A external |
| Power consumption | 9 W |
| rated conditional short-circuit current | 100 A |
| Rated insulation voltage Ui | 32 V |
| Rated impulse voltage Uimp | 0.8 kV |
| Operating voltage DC | |
| UB | 24 V DC -15% ... +20% (reverse polarity protected, regulated, residual ripple<5%, SELV) |
| Discrepancy time | max. 10 ms |
| Turn-on time | max. 400 ms |
| EMC protection requirements | Acc. to EN IEC 60947-5-3 |
| Solenoid operating voltage DC | 24 V DC -15% ... +20% reverse polarity protected, regulated, residual ripple<5%, SELV |
| Solenoid duty cycle | 100 % |
| Risk time according to EN 60947-5-3 | max. 200 ms |
| Risk time according to EN 60947-5-3, extension for each additional device | max. 10 ms |
| Switching load | |
| according to UL | DC 24 V, Class 2 |
| Safety class | III |
| Current consumption | |
| IIMP | 500 mA |
| IUB | 50 mA |
| Degree of contamination (external, according to EN 60947-1) | 3 |
| Monitoring output Ox/C | |
| Output type | p-switching, short circuit-proof |
| Output voltage | 0.8xUB ... UB V DC |
| Output current | 1 ... 10 mA |
| Safety outputs FO1A, FO1B | |
| Output type | Semiconductor outputs, p-switching, short circuit-proof |
| Output voltage | |
| UFO1A /UFO1B LOW | 0 ... 1 V DC |
| UFO1A /UFO1B HIGH | UB-4V ... UB V DC (Value at a switching current of 50mA without taking into account the cable lengths) |
| Output current | |
| per safety output FO1A / FO1B | 1 ... 75 mA |
| Utilization category | |
| DC-13 | 24V 75mA (Caution: outputs must be protected with a free-wheeling diode in case of inductive loads) |
| Test pulse duration | max. 0.3 ms |
| Test pulse interval | min. 96 ms |
Mechanical values and environment
| Anfahrgeschwindigkeit | max. 20 m/min |
| Extraction force | 25 N |
| Ready delay | max. 1 s |
| Actuating force | 25 N |
| Installation orientation | any |
| Storage temperature | -25 ... 70 °C |
| Mechanical life | 1 x 10⁶ |
| Retention force | 10 N |
| Shock and vibration resistance | Acc. to EN IEC 60947-5-3 |
| Degree of protection | IP65/IP67/IP69/IP69K |
| Ambient temperature | -20 ... 50 °C |
| Material | |
| Connecting cable | PVC |
| Safety switch housing | Reinforced thermoplastic |
| Switch head cover | Die-cast zinc |
| Locking force Fmax | 5000 N |
| Locking force FZh | 3800 N |
| Guard locking principle | Open-circuit current principle |
| Connection X1 | |
| Connection type | Connecting cable with plug connector M12 |
| Static bending radius | 8x cable diameter |
| Cable outlet | straight |
| Cable length | 0.25 m |
| Number of pins | 8 |
| Safety outputs FO1A, FO1B | |
| Switching frequency | max. 0.2 Hz |
Characteristic values according to EN ISO 13849-1 and EN IEC 62061
| PL | Maximum SIL | PFHD | Category | Mission time | |
|---|---|---|---|---|---|
| Monitoring of the guard position | PL e | 3 | 6.44x10-9 | 4 | 20 y |
Miscellaneous
| Notices for UL approval | Operation only with UL Class 2 power supply or equivalent measures; see operating instructions |
Aksesuar

A-FLX-D-0C-167919
- Function actuator for configuration of the safety switch CTS
- Configuration: monitoring of the guard locking, high coding level (L+HC)

A-FLX-D-0E-169045
- Function actuator for configuration of the safety switch CTS
- Configuration: monitoring of the guard locking, low coding level (L+LC)

A-FLX-D-0D-169044
- Function actuator for configuration of the safety switch CTS
- Configuration: monitoring of the door position, high coding level (I+HC)

A-FLX-D-0F-169046
- Function actuator for configuration of the safety switch CTS
- Configuration: monitoring of the door position, low coding level (I+LC)
İndirme
Komple paket
Tüm önemli belgeleri tek bir tıklama ile indirin.
İçerik:
- Kullanım talimatları ve kullanım talimatlarına veya kısa talimatlara yapılan tüm eklemeler
- Kullanım talimatlarını tamamlayan tüm veri sayfaları
- Uygunluk beyanı
Tek Belgeler
Diğer Belgeler
CAD Verileri
Sipariş verileri
| Sip. No. | 169051 |
| Makale adı | CTS-C2-BP-CC-FLX-AP-VSA-169051 |
| Ağırlık | 0,6kg |
| Gümrük sınıfı | 85365019000 |
| ECLASS | 27-27-24-05 Safety-related transponder switch with guardlocking |